• Title/Summary/Keyword: point estimation

Search Result 2,112, Processing Time 0.026 seconds

A Study on Accounting for Nursing Cost by Korean Diagnosis Related Groups (K - DRGs) (종합병원(綜合病院)의 간호행위양상(看護行爲樣相)에 따른 간호원가(看護原價) 산정(算定)에 관(關)한 연구(硏究))

  • Oh, Hyo-Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.5-46
    • /
    • 1989
  • The current medical payment Insurance Rates in Korea stipulate charges for medical treatment by the doctor, pharmaceutist, medical technician and maternity nurse. But unfortunately didn't specify those charges for nursing done by the professional nurse. Only basic nursing fee is accounted insufficiently in current medical insurance fee schedule. therefore, Being face with covering entire people by medical insurance by 1991, It seems that the problems pertaining to operating the hospital and medical insurance system would be incessantly expanded in that no mention is made of medical charges rendered by major medical producer service in the current system, For that reason, this study made an attempt to clarify the importance the professional nursing puts of the current medical payment. The purpose of this study was to accounting nursing fee which diveded into the current medical fee schedule. (Method) 1. Data collection; Importance and difficulties in nursing activities was conducted in 'S' National University Hospital. Total nursing activities were selected 72 items which included direct care and indirect care. This study was conducted to evaluating the degree of importance and difficulties according to nursing activities through questionnaire to 204 RN. and so relative difficulties (acuity) were computered because the nursing cost level of each nursing service was differently established by the equivalent coefficient according to degree of relative difficulty and time required. 2. Calculation of cost according to nursing activities; After 47 nursing activities were selected in General surgery nursing units, calculation of nursing cost was as follows Cost of Nursing activity = (relative difficulty X Average hourly wage and benefits of nurse) + material cost of nursing -t- Average nursing administration cost So, Calculated cost by nursing activities was compared to current non-insured and insurance rate. 3. Calculation of nursing cost by K - DRG ; Total of 578 patients who were hospitalized in General Surgery units from January to March 1988 ware classified by K - DRG After estimation of total nursing cost based on the K-DRG, verified the appropriateness of basic nursing fee in medical insurance rate (Results) 1. Analysis of degree of importance and difficulties were 4.16 and 3.67 based on 5 point scale. This score were judged that it is worthy specifying the nursing fee 2. The nursing cost of 47 nursing service items in general surgery patients showed that the average cost of nursing activity was \1374.5 and The lowest cost was \217 of 'oral administration nursing' item, The highest cost was \11,025 of 'saline enematill clear' item 3. The result of comparison between the calculated cost by nursing activities against the current non-insured and insurance rate showed that 13 items(27.7%) involved to payment of insurance rate, 9 items(19.1%) involved to non-insured rate, remainder 25 items (53.2%) were not charged anywhere of total 47 nursing activities 4. When calculated cost by nursing activities was 100. current insurance rate was 62.3, non-insured rate was 176.6. Therefore this showed that most of non-insured rate were higher than calculated nursing cost. The insurance rate, however, were lower than it. Reim-bursement was imputed to non-insured patients. So the current rate system became estrainged from cost system. When Remainder 25 items of nursing activities compared' to \1390 of daily basic nursing fee per patient belonged to payment as a insurance fee schedule, basic nursing fee schedule was 1-2% of calculated cost of nursing activities. Therefore it showed that nursing fee was not counted adequately in it. 5. Nursing cost by K-DRG estimated in chart review based on counting number of nursing activities and length of stay The result showed that average amount of total nursing cost was \183828.1 Comparison of nursing cost calculated by K- DRG and basic nursing fee schedule showed that only 12.3% of nursing cost was charged (Conclusion) From the above research result, It is fact that nursing prime cost should be estimated more accurately and included adequately in current medical payment system. The payment system of nursing activities should be introduced not only nursing activities of drug administration and injection fee belonged to insurance fee schedule but also most nursing activities belonged not to mekical fee schedule. Even if introducing payment system of nursing activities, It should be estimated scientific method of Accounting nursing cost So nurses could offer nursing care of good quality, thereby they could make a great contribution not merely to the convalescence of the patient but to the promotion of the people's health.

  • PDF

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

Estimation of the Superelevation Safety Factor Considering Operating Speed at 3-Dimensional Alignment (입체선형의 주행속도를 고려한 편경사 안전율 산정에 관한 연구)

  • Park, Tae-Hoon;Kim, Joong-Hyo;Park, Je-Jin;Park, Ju-Won;Ha, Tae-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.159-163
    • /
    • 2005
  • The propriety between suppliers and demanders in geometric design is very important. Although the final purpose of constructing roads is to concern about the driver s comfort, unfortunately, it has not been considered so far. We've considered the regularity and quickness in considering driver's comfort but there should be considered the safety for the accident as well. If drivers are appeared to be more speeding than designer's intention, there will be needed some supplements to increase the safety rate for the roads. Even if both an upward and downward section are supposed to exist at the same time for solid geometry of the roads like this, it is true that the recent design for the 3-D solid geometry section has been done as flat 2-D and the minimum plane curve radius and the maximum cant have been decided just by calculating without considering operating speed between an upward and downward section at the same point. In this investigation, thus, I'd like to calculate the safety of the cant by considering the speed features of the solid geometry for the first lane of four lane rural roads. To begin with, we investigated the driving speed of the car, which is not been influenced by a preceding car to analyze the influence of the geometrical structure by using Nc-97. Secondly, we statistically analyzed the driving features of the solid geometry after comparing the 6 sections, that is, measuring the driving speed feature at 12 points and combining the influence of the vertical geometry and plane geometry to the driving speed of the plane curve which was researched before. Finally, we estimated the value of cant which considers the driving speed not by using it which has applied uniformly without considering it properly, though there were some differences between a designed speed and driving speed through the result of the basic statistical analysis but by introducing the new safety rate rule, a notion of ${\alpha}$. As a result of the research, we could see the driving features of the car and suggest the safety rate which considers these. For considering the maximum cant, if we apply the safety rate, the result of this experiment, which considers 3-D solid geometry, there'll be the improvement of the driver's safety for designing roads. In addition, after collecting and analyzing the data for the road sections which have various geometrical structures by expanding this experiment it is considered that there should be developed the models which considers 3-D solid geometry.

Estimation of Growth Curve for Evaluation of Growth Characteristics for Hanwoo cows (한우암소의 성장특성 평가를 위한 성장곡선의 추정)

  • Lee, C.W.;Choi, J.G.;Jeon, K.J.;Na, K.J.;Lee, C.;Yang, B.K.;Kim, J.B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.509-516
    • /
    • 2003
  • Growth curves were estimated for 1083 female Korean cattle raised in Daekwanryeong branch, National Livestock Research Institute (NLRI). Comparisons were made among various growth curve models for goodness of fit for the growth of the cows. Estimated growth curve functions were $W_t=370.2e^{-2.208e^{-0.00327t}$ for Gompertz model, for von Bertalanffy model, and $W_t=341.2(1+5.652e^{-0.00524t})^{-1}$ for Logistic model. Ages at inflection estimated from Gompertz model, von Bertalanffy model and Logistic model were 242.2 days, 191.5 days, and 330.5 days respectively, body weight at inflection were 136kg, 115kg, and 170kg, and daily gain at inflection were 0.445kg, 0.451kg, and 0.446kg. The predicted weights by ages from Gompertz model, von Bertalanffy model, and Logistic model were onsistently overestimated at birth weight and underestimated at 36 month weight. The von Bertalanffy model which had a variable point of inflection fit the data best.

Estimation of Evaporation Rate of Swine Slurry Using the Natural Evaporation System(NES) in summer (여름철 자연증발시스템(NES)의 腞슬러리 증발효율 평가)

  • Kim, K.Y.;Choi, H.L.;Kim, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.459-474
    • /
    • 2002
  • The purpose of this study was to establish the optimal operation condition of the natural evaporation system(NES) which was used for reducing swine slurry. Especially the main point of this study is to estimate the effect of climate condition(clear & rainy) and spray type(batch & flow) for the evaporation rate of swine slurry applying the NES in summer. Experiment was performed from June to August, which was generally regarded as summer in Korea, with the spray type of batch in 2000 and that of flow in 2001. As a result of experiment for batch and flow type, the averaged evaporation rate was measured into 2.71 and 3.59 l/ton . $m^2$ . day on clear days and 0.62 and 0.66 l/ton . $m^2$ . day on raint days, respectively. Based on the calculated evaporation rate by the climate condition and the spray type, it was proved that the averaged reduction rate for total input(1t/day) were 15.99% and 3.19% on clear and rainy days and the evaporation rate of the flow type was superior to that of the batch type by 5%, approximately. Therefore, it was concluded that the supplementary equipment, such as fan, should by operated in rainy days and the spray type of flow rather than that of batch should be recommended to increase the evaporation rate in the natural evaporation system(NES).

Estimation of Fetal Dose during Radiation Therapy of Pregnant Patient (임산부의 방사선치료 시 태아선량 평가)

  • Jung, Chi-Hoon;Kim, Chan-Yong;Kim, Bo-Gyum;Seo, Suk-Jin;Yoo, Sook-Hyun;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Purpose: To evaluate the effectiveness of a simple and practical shielding device to reduce the fetal dose for a pregnant patient undergoing radiation therapy of brain metastasis. Materials and Methods: The dose to the fetus was evaluated by simulating the treatments using the anthropomorphic phantom. The prescription dose at mid-brain is $300cGy{\times}10$ fractions with 6 MV photon with $18{\times}22cm^2$ field size. The additional shielding devices to reduce the fetal dose are a shielding wall, cerrobend plates and lead (Pb) sheets over acrylic bridge. Various points of measurement with off-field distance were detected by using ion-chamber (30, 40, 50, and 60 cm) with and without the shielding devices and TLD (30, 40, 50, 60, and 70 cm) only with the shielding devices. Results: The doses to the fetus without shielding were 3.20, 3.21, 1.44, 0.90 cGy at the distances of 30, 40, 50, and 60 cm from the treatment field edge. With shielding, the doses were reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy (70 cm). The total dose to the fetus was expected to be under 1 cGy during the entire treatment. Conclusion: The essential point during radiation therapy of pregnant patient would be minimizing the fetal dose. 10 cGy to 20 cGy is the threshold dose for fetal radiation effects. Our newly developed device reduced the fetal dose far below the safe level. Therefore, our additional shielding devices are useful and effective to reduce the fetal dose.

  • PDF

The Study on Risk Factors Analysis and Improvement of VDT Syndrome in Nuclear Medicine (핵의학과 Video Display Terminals Syndrome 유해 요인 조사 및 개선에 관한 연구)

  • Kim, Jung-Soo;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo;Han, In-Im;Joo, Yung-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: Recently, Department of Nuclear Medicine have an interest in Video Display Terminals (VDT) syndrome including musculoskeletal disorders, ophthalmologic disorders, trouble of electromagnetic waves and stress disorders occur to VDT workers as the growing number of users and rapid pace of service period supply in large amount. This study research on the actual condition for VDT syndrome in Nuclear Medicine, Seoul National University Hospital (SNUH), discover the problem and draw a plan of upcoming improvement. The aim of this study establish awareness about VDT syndrome and is to prevent for it in the long run. Materials and Methods: Department of Nuclear Medicine, SNUH is composed Principle part, Pediatric part and PET center. We estimated risk factors visit in each part directly. Estimation method use "Check list for VDT work" of Wonjin working environment health laboratory and check list is condition of VDT work, condition of work tables, condition of chairs, condition of keyboards, condition of monitors, working position, character of health management and other working environment. Analysis result is verified in Department of Occupational and Environment, Hallym University Sacred Heard Hospital. Results: As a result of analysis, VDT condition of Department of Nuclear Medicine, SNUH is rule good. In case of work tables, recent of things are suitable to users upon the ergonomical planning, but 15% of existing work tables are below the standard value. In case of chairs are suitable, but 5% of theirs lost optimum capacity become superannuated. The keyboards are suitable for 98% of standard value. In case of monitors, angle control of screen is possible of all, but positioning control is impossible for 38%. In case of working position, 10% is fixed positioning for long time and some of the items researched unsuitable things for standard. At health management point, needed capable of improvement. Also, other working condition as lighting, temperature, noise and ventilation, discovered the problem, but is sufficient to advice value. Conclusion: VDT syndrome is occurrences of possibility continuously, come economical expensive about improvement, is inherent in various causes and originate without your knowledge. So, there is need systematic management system. In Nuclear Medicine, VDT syndrome make it better that constant interest and effort as improvement of ergonomical working environment, improvement of working procedure, regular exercise and steady stretching, and can be prevented fairly. This promote physical and mental condition of worker in top form in comfortable working environment, so this is judged by enlargement of operations efficiency and rising of satisfaction ratings of the inside client.

  • PDF

Development and Application of the SWAT HRU Mapping Module for Estimation of Groundwater Pollutant Loads for Each HRU in the SWAT Model (SWAT HRU별 지하수 오염부하량 산정을 위한 SWAT HRU Mapping Module 개발 및 적용)

  • Ryu, Ji Chul;Mun, Yuri;Moon, Jongpil;Kim, Ik Jae;Ok, Yong Sik;Jang, Won Seok;Kang, Hyunwoo;Lim, Kyoung Jae
    • Journal of Environmental Policy
    • /
    • v.10 no.1
    • /
    • pp.49-70
    • /
    • 2011
  • The numerous efforts have been made in understanding generation and transportation mechanism of nonpoint source pollutants from agricultural areas. Also, the water quality degradation has been exacerbated over the years in many parts of Korea as well as other countries. Nonpoint source pollutants are transported into waterbodies with direct runoff and baseflow. It has been generally thought that groundwater quality is not that severe compared with surface water quality. However its impacts on groundwater in the vicinity of stream quality is not negligible in agricultural areas. The SWAT model has been widely used in hydrology and water quality studies worldwide because of its flexibilities and accuracies. The spatial property of each HRU, which is the basic computational element, is not presented. Thus, the SWAT HRU mapping module was developed in this study and was applied to the study watershed to evaluate recharge rate and $NO_3-N$ loads in groundwater. The $NO_3-N$ loads in groundwater on agricultural fields were higher than on forests because of commercial fertilizers and manure applied in agricultural fields. The $NO_3-N$ loads were different among various crops because of differences in crop nutrient uptake, amount of fertilizer applied, soil properties in the field. As shown in this study, the SWAT HRU mapping module can be efficiently used to evaluate the pollutant contribution via baseflow in agricultural watershed.

  • PDF

Changes in Transpiration Rates and Growth of Cucumber and Tomato Scions and Rootstocks Grown Under Different Light Intensity Conditions in a Closed Transplant Production System (식물공장형육묘시스템 내 광량에 따른 오이와 토마토 접수 및 대목의 증발산량 및 생육 변화)

  • Park, Seon Woo;An, Sewoong;Kwack, Yurina
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.399-405
    • /
    • 2020
  • Recently, it is difficult to produce uniform scions and rootstocks with high quality in a greenhouse due to weather extremes. The closed transplant production system is useful for producing scions and rootstocks with desirable morphological characteristics by environment control regardless of weather outside. In this study, we investigated transpiration rates and growth of cucumber and tomato scions and rootstocks grown under different light intensity conditions for precise irrigation control in a closed transplant production system. Hanging system to measure continuously the weight of plug tray consisting of seedlings and substrate with load-cell was installed in each growing bed. Using this system, we confirmed initial wilting point of cucumber and tomato seedlings, and conducted subirrigation when moisture content of substrate was not below 50%. The irrigation time of cucumber scions and rootstocks were 7 and 6 days after sowing, respectively. In tomato scions and rootstocks grown under PPF (photosynthetic photon flux) 300 μmol·m-2·s-1, the irrigation time were 5, 8, 11, and 13 days after sowing. Increasing light intensity increased transpiration rates and differences of transpiration rates by light intensity was higher in tomato seedlings. The growth of cucumber and tomato seedlings was promoted by increasing light intensity, especially, hypocotyl elongation and stem thickening was affected by light intensity. Cumulative transpiration rate of plug tray in cucumber and tomato seedlings was increased by increasing light intensity, and daily transpiration rate per seedling was regressed by 1st-order linear equation with high correlation coefficient. Estimation of transpiration rates by weighing continuously plug tray of vegetable seedlings can be useful to control more accurately irrigation schedule in a closed transplant production system.