• Title/Summary/Keyword: point bar

Search Result 436, Processing Time 0.029 seconds

Effects of Aqua-Acupuncture of Yukmijihwangtang and Palmijihwangtang Water Extracts on the Renal Function (육미지황탕(六味地黃湯)및 팔미지황탕(八味地黃湯)의 약침(藥鍼)이 신장기능(腎臟機能)에 미치는 영향(影響))

  • Lee Moon-Ho;Son In-Chul
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.255-277
    • /
    • 1998
  • The aim of this experiment was to investigate the effects of Aqua-Acupuncture of Yukmijiwangtang(六味地黃湯) and Palmijihwang-tang(八味地黃湯) water extracts applied at the meridian points BL 23(賢兪) and GV 4(命門) to test the renal function in normal rats. The results obtained were as follows; 1. Among the effects of Aqua-Acupuncture of Yukmijihwangtang water extract at the merdian point BL 23 group, there were significant changes in water balance and urine volume over a 1 week period; Both decreasing and decreasing trends were exihibited. Urinary excretion of sodium and free water clearance changed significantly over a 2 week period; Both decreasing and increasing trends were exihibited, Urinary excretion of potassium, chloride and creatinine, plasma renin activity, plasma levels of aldosterone and atrial natriuretic peptide showed no significant differences compared to the contral group. 2. Among the effects of Aqua-Acupuncture of Palmljihwangtang water extract at the merdian point BL 23 group, there were significant changes in water balance and free water clearance over a 2 week period; a decreasing trend. Urinary excretion of creatinine changed significantly over a 2 week period; an increasing trend. Urinary excretion of chloride changed significantly over 1 week period; an increasing trend. The plasma levels of atrial natriuretic peptide changed significantly over 1 and 2 week period; an increasing trend. Urine volume, urinary excretion of sodium and pottasium, plasma renin activity and plasma level of aldosterone showed no significant differences compared to the control group. 3. Among the effects of Aqua-Acupuncture of Yukmijihwangtang water extract at the meridian point GV 4 group, there was significant decrease in water balance over a 2 week period; there was significant decrease in urine volwne and urinary excretion of sodium and creatinine over a 1 week period, followed by an increasing trend after 2 weeks. Urinary excretion of free water clearance demonstrated significant changes over both 1 and 2 week period; both increasing and decreasing trends were exihibited. Urinary excretion of chloride and plasma levels of aldosterone increased significantly over 1 and 2 week period. Plasma levels of atrial natriuretic peptide also decreased significantly. Plasma renin activity showed no significant differences compared to the control group. 4. Among the effects of Aqua-Acupuncture of Palmijihwangtang water extract at the meridian point GV 4 group, water balance and urinary excretion of chloride, plasma levels of aldosterone decreased significantly over both 1 and 2 week period. Urine volume and urinary excretion of pottasium decreased significantly. Urinary excretion of creatinine and urinary excretion of sodium changed significantly over both 1 and 2 week period. Urinary excretion of free water clearance, plasma renin activity and plasma level of atrial natriuretic peptide showed no significant differences compared to the control group. Seeing these results, I come to know that the effects Aqua-Acupuncture of Yukmijihwangtang and Palmijihwangtang water extracts at the meridian point BL 23 and GV 4 have affected the renal function differently. Seeing the results that BL 23 is a meridian point for Aqua-Acupuncture directly related to the kidney, I think, we can use Aqua-Acupuncture of Yuk-mijihwangtang and Palmijihwangtang water extracts to prevent and to treat the diseases related to kidney.

  • PDF

A Fundamental Study on the Effect to Build up a Vegetation Strip at Stream Confluence by Using Reed Mat (하천합류부에서 갈대매트를 이용한 하천식생대 조성에 대한 기초적 연구)

  • Chung, Kyung-Jin;Kim, Mi-Kyeong;An, Won-Yong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.4
    • /
    • pp.62-73
    • /
    • 2003
  • The study was to apply a mat style reed planting method at confluence to improve plants growth conditions by relaxing disturbed topographical base due to water flow and was intended to review the effect to build up a vegetation strip by monitoring process after the construction. First off, We've attempted to construct reed mats on selected sites as confluences of Tan and Gaehwa stream and then examined and analyzed characteristics of soil and vegetation community. As the results of the examination, the soil texture was proven to be a mix of sand and loamy sand and be 6.3 ~ 7.0 soil pH. In addition, it contained 1.0 ~ 4.6% of organic matter, 0.04 ~ 0.22% of T-N and 27.8 ~ 41.2% of water content. For its vegetation structure, the Tan stream confluence was first actually a point bar without plants prior to the construction but 8 kinds of hygrophytes including Persicaria hydropiper and 9 kinds of terrestrial plants such as Potentilla supina, Artemisia annua, and Alopecurus aequalis var. amurensis. On the other hand, the Gaehwa stream confluence contained 6 kinds of hygrophytes such as Bidens frondosa and other 11 kinds of terrestrial plants prior to the construction while it produced 7 kinds of hygrophytes including Ranunculus ternatus as well as Phragmites australis and 9 kinds of terrestrial plants such as Potentilla supina after the construction. For the Phragmites australis, almost of them was weathered away in early days just after planting because of development period passed, but on May, six months later from planting, it was investigated that its length was approximated as 65 ~ 85cm with 75% coverage and that the number of it was 437 ~ 633/$m^2$. The study was shown that reed mats can improve environmental conditions of disturbed topographical base, enabling natural growth of various riparian vegetation including the introduced plant, reed. In the meantime, it was supposedly judged that to recover or build up a vegetarian strip, supplementary materials should be prepared to help produce and grow plants because it is not probable to expect river drift by water flow at confluence and that corrosion, burying or inundation owing to changes of water lever should be considered.

3-Dimensional Performance Optimization Model of Snatch Weightlifting

  • Moon, Young-Jin;Darren, Stefanyshyn
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.157-165
    • /
    • 2015
  • Object : The goals of this research were to make Performance Enhanced Model(PE) taken the largest performance index (PI) through artificial variation of principle components calculated by principle component analysis for trial data, and to verify the effect through comparing kinematic factors between trial data (Raw) and PE. Method : Ten subjects (5 men, 5 women) were recruited and 80% of their maximal record was considered. The PI is a regression equation. In order to develop PE, we extracted Principle components from trial position data (by Principle Components Analysis (PCA)). Before PCA, we made 17 position data to 3 row matrix according to components. We calculated 3 eigen value (principle components) through PCA. And except Y (medial-lateral direction) component (because motion of Y component is small), principle components of X (anterior-posterior direction) and Z (vertical direction) components were changed as following. Changed principle components = principle components + principle components ${\times}$ k. After changing the each principle component, we reconstructed position data using the changed principle components and calculated performance index (PI). A Paired t-test was used to compare Raw data and Performance Enhanced Model data. The level of statistical significance was set at $p{\leq}0.05$. Result : The PI was significantly increased about 12.9kg at PE ($101.92{\pm}6.25$) when compared to the Raw data ($91.29{\pm}7.10$). It means that performance can be increased by optimizing 3D positions. The difference of kinematic factors as follows : the movement distance of the bar from start to lock out was significantly larger (about 1cm) for PE, the width of anterior-posterior bar position in full phase was significantly wider (about 1.3cm) for PE and the horizontal displacement toward the weightlifter after beginning of descent from maximal height was significantly greater (about 0.4cm) for PE. Additionally, the minimum knee angle in the 2-pull phase was significantly smaller (approximately 2.7cm) for the PE compared to that of the Raw. PE was decided at proximal position from the Raw (origin point (0,0)) of PC variation). Conclusion : PI was decided at proximal position from the Raw (origin point (0,0)) of PC variation). This means that Performance Enhanced Model was decided by similar motion to the Raw without a great change. Therefore, weightlifters could be accept Performance Enhanced Model easily, comfortably and without large stress. The Performance Enhance Model can provide training direction for athletes to improve their weightlifting records.

Shear Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 전단성능)

  • Hwang, Seung-Bum;Seo, Soo-Yeon;Lee, Kang-Cheol;Lee, Seok-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.489-496
    • /
    • 2016
  • Recently, a concern about hollow core precast concrete (PC) slab has been increased as a method to improve the construction ability by reducing the self weight of structures during the construction. Hollow core slab which is known as a typical PC slab in domestic construction of PC building has a problem to put shear reinforcements in the web of element during the production of element in the factory. With regard to this point, recently, tripple ribs slab (TRS) which can be said as a new type of half PC slab system was developed. In TRS, it is possible to place shear reinforcements in PC element during the production of the element in the factory. This paper presents the shear test result of TRS which was done by one point loading test under simple support condition. Test parameters are the presence of cast-in-place (CIP) concrete and the contribution of lattice bars. From the test, it was found that the TRS has sufficient shear capacity to resist the design load and its strength can be predicted by the code equations for general beam. It is recommended to ignore the strength of lattice bar in the calculation of shear strength during the construction since its contribution is too low to be considered when CIP is not casted.

Flexural Test for Prefabricated Composite Columns Using Steel Angle and Reinforcing Bar (앵글과 철근을 조립한 PSRC 합성기둥의 휨 실험)

  • Eom, Tae-Sung;Hwang, Hyeon-Jong;Park, Hong-Gun;Lee, Chang-Nam;Kim, Hyoung-Seop
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.535-547
    • /
    • 2012
  • PSRC column is a concrete encased steel angle column. In the PSRC column, the steel angles placed at the corner of the cross-section resists bending moment and compression load. The lateral re-bars welded to steel angles resist the column shear and the bond between the steel angle and concrete. In the present study, current design procedures in KBC 2009 were applied to the flexure-compression, shear, and bond design of the PSRC composite column. To verify the validity of the design method and failure mode, simply supported 2/3 scaled PSRC and correlated SRC beams were tested under two point loading. The test parameters were the steel angle ratio and lateral bar spacing. The test results showed that the bending, shear, and bond strengths predicted by KBC 2009 correlated well with the test results. The flexural strength of the PSRC specimens was much greater than that of the SRC specimen with the same steel ratio because the steel angles were placed at the corner of the column section. However, when the bond resistance between the steel angle and concrete was not sufficient, brittle failures such as bond failure of the angle, spalling of cover concrete, and the tensile fracture of lateral re-bar occurred before the development of the yield strength of PSRC composite section. Further, if the weldability and toughness of the steel angle were insufficient, the specimen was failed by the fracture of the steel angle at the weld joint between the angle and lateral bars.

Nonlinear Finite Element Analysis of the Reinforced Concrete Panel using High-Strength Reinforcing Bar (고강도 철근을 사용한 철근콘크리트 패널의 비선형 유한요소해석)

  • Cheon, Ju-Hyun;Seong, Dae-Jung;Cho, Hong-Jae;Cho, Jae-Yeol;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.481-488
    • /
    • 2015
  • The purpose of this study is to provide analytical method to reasonably predict the overall behavior up to destruction of reinforced concrete panel specimens using high-strength reinforcing bar. A total of 12 specimens of reinforced concrete panels with a wall thickness one-third the size of the actual nuclear containment structures under various loading conditions and design parameters were selected and the analysis was performed using a non-linear finite element analysis program (RCAHEST) was developed by the authors. The mean and coefficient of variation for shear strength at cracking point and maximum shear strength from the experiment and analysis results was predicted 1.03 and 12%, 0.97 and 9%, respectively. For the shear strain at the maximum shear strength from the experiment and analysis results was predicted 0.96 and 30%, respectively. Based on the results, the analysis program that was applied newly modified constitutive equation in this study is judged as having a relatively high reliability for the analysis results.

Study of Supercritical Carbon Dioxide/n-Butyl Acetate Co-solvent System with High Selectivity in Photoresist Removal Process (포토레지스트 공정에서 높은 선택성을 가지는 초임계 이산화탄소/n-butyl acetate 공용매 시스템 연구)

  • Kim, Dong Woo;Heo, Hoon;Lim, Kwon Teak
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.357-363
    • /
    • 2017
  • In this study, the supercritical carbon dioxide ($scCO_2$)/ n-butyl acetate (n-BA) co-solvent system was employed to remove an unexposed negative photoresist (PR) from the surface of a silicon wafer. In addition, the selectivity of the $scCO_2$/n-BA co-solvent system was confirmed for the unexposed and exposed negative PR. Optimum conditions for removal of the unexposed PR were obtained from various conditions such as pressure, temperature and n-BA ratio. The n-BA was highly soluble in $scCO_2$ without cloud point and phase separation in mostly experimental conditions. However, the $scCO_2$/n-BA co-solvent was phase separated at 100 bar, above $80^{\circ}C$. The unexposed and exposed PR was swelled in $scCO_2$ solvent at all experimental conditions. The complete removal of unexposed PR was achieved from the reaction condition of 160 bar, 10 min, $40^{\circ}C$ and 75 wt% n-BA in $scCO_2$, as measured by ellipsometry. The exposed photoresist showed high stability in the $scCO_2$/n-BA co-solvent system, which indicated that the $scCO_2$/n-BA co-solvent system has high selectivity for the PR removal in photo lithograph process. The $scCO_2$/n-BA co-solvent system not only prevent swelling of exposed PR, but also provide efficient and powful performance to removal unexposed PR.

Study on a Suspension of a Planetary Exploration Rover to Improve Driving Performance During Overcoming Obstacles

  • Eom, We-Sub;Kim, Youn-Kyu;Lee, Joo-Hee;Choi, Gi-Hyuk;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.381-387
    • /
    • 2012
  • The planetary exploration rover executes various missions after moving to the target point in an unknown environment in the shortest distance. Such missions include the researches for geological and climatic conditions as well as the existence of water or living creatures. If there is any obstacle on the way, it is detected by such sensors as ultrasonic sensor, infrared light sensor, stereo vision, and laser ranger finder. After the obtained data is transferred to the main controller of the rover, decisions can be made to either overcome or avoid the obstacle on the way based on the operating algorithm of the rover. All the planetary exploration rovers which have been developed until now receive the information of the height or width of the obstacle from such sensors before analyzing it in order to find out whether it is possible to overcome the obstacle or not. If it is decided to be better to overcome the obstacle in terms of the operating safety and the electric consumption of the rover, it is generally made to overcome it. Therefore, for the purpose of carrying out the planetary exploration task, it is necessary to design the proper suspension system of the rover which enables it to safely overcome any obstacle on the way on the surface in any unknown environment. This study focuses on the design of the new double 4-bar linkage type of suspension system applied to the Korea Aerospace Research Institute rover (a tentatively name) that is currently in the process of development by our institute in order to develop the planetary exploration rover which absolutely requires the capacity of overcoming any obstacle. Throughout this study, the negative moment which harms the capacity of the rover for overcoming an obstacle was induced through the dynamical modeling process for the rocker-bogie applied to the Mars exploration rover of the US and the improved version of rocker-bogie as well as the suggested double 4-bar linkage type of suspension system. Also, based on the height of the obstacle, a simulation was carried out for the negative moment of the suspension system before the excellence of the suspension system suggested through the comparison of responding characteristics was proved.

Experimental Study for GFRP Reinforced Concrete Beams without Stirrups (스터럽이 없는 GFRP 보강근 콘크리트 보에 대한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.21-29
    • /
    • 2014
  • This paper evaluates the shear strength, behavior and failure mode of reinforced concrete beams with deformed GFRP reinforcing bar. Four concrete beam specimens were constructed and tested. It was carried out to observe failure behavior and load-deflection of simply supported concrete beams subjected to four-point monotonic loading. In order to eliminate of the uncertainty by the shear reinforcements, any stirrups were not used. Variables of the specimens were shear span-depth ratio, effective reinforcement ratio. The dimensions of specimen is 3,300 or $1,950mm{\times}200mm{\times}240mm$. Clear span and shear span were 2,900mm, 1,000mm respectively. Shear span-depth ratios were 6.5 and 2.5. Effective ratios of Longitudinal GFRP reinforcing bar were $1.126{\rho}_{fb}$, $2.250{\rho}_{fb}$, $3.375{\rho}_{fb}$ and $0.634{\rho}_{fb}$. All beam specimens were broken by diagonal-tension shear and the ACI 440.1R, CSA S806 and ISIS, which was used to design test beams, showed considerable deviation between prediction and test results of shear strengths.

Behavior of Reinforcement Ratio on Concrete Beams Reinforced with Lab Spliced GFRP Bar (GFRP 보강근으로 겹이음된 콘크리트 보의 보강비에 따른 거동특성)

  • Choi, Yun Cheul;Park, Keum Sung;Choi, Hyun Ki;Choi, Chang Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.67-76
    • /
    • 2011
  • The use of glass-fiber-reinforced polymer (GFRP) bars in reinforced concrete (RC) structures has emerged as an alternative to traditional RC due to the corrosion of steel in aggressive environments. Although the number of analytical and experimental studies on RC beams with GFRP reinforcement has increased in recent decades, it is still lower than the number of such studies related to steel RC structures. This paper presents the experimental moment deflection relations of GFRP reinforced beam which are spliced. Test variables were different reinforcement ratio and cover thickness of GFRP rebars. Seven concrete beams reinforced with steel GFRP re-Bars were tested. All the specimens had a span of 4000mm, provided with 12.7mm nominal diameter steel and GFRP rebars. All test specimens were tested under 2-point loads so that the spliced region be subject to constant moment. The experimental results show that the ultimate moment capacity of beam increasing of the reinforcement ratio. Failure mode of these specimens was sensitively vary according to the reinforcement ratio. The change of beam effective depth, which was caused by cover thickness variation, controlled the maximum strength and deflection because of cover spalling in tension face.