• Title/Summary/Keyword: plastic magnet

Search Result 36, Processing Time 0.033 seconds

Comparison and Electromagnetic Analysis of BLDC Motors with Radial and Polar Plastic Magnets (반경 및 원주 방향 자화된 플라스틱 자석을 갖는 BLDC 전동기의 전자기적 특성해석 및 비교)

  • Jang, Seok-Myeong;Cho, Jang-Young;Cho, Han-Wook;Yang, Hyun-Sup;Lee, Sung-Ho;Jeong, Sang-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.25-27
    • /
    • 2005
  • This paper deals with the comparison and analysis of brushless DC (BLDC) motor with radial and polar anisotropic plastic magnet. The open-circuit field distributions and back-emf for BLDC motor with polar plastic magnet are established analytically and the results are validated extensively by comparison with finite element (FE) analyses. On the basis of two dimensional (2-D) analytical solutions, this paper predicts open-circuit field characteristics according to design parameters and makes a comparison between BLDC motor with polar plastic magnet and it with radial plastic magnet in terms of required magnet volume and harmonic of air-gap flux density waveform.

  • PDF

Design of Magnetic Circuit for Orientation of a Plastic Magnet (플라스틱 자석 배향용 자기회로 설계)

  • Kim, Chang-Eob;Kim, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.183-185
    • /
    • 1998
  • In this paper, a magnetic circuit of plastic magnet roller for laser printer is presented. The magnetization direction of plastic magnet is decided by the flux distribution of injection mold during the manufacturing process. The injection mold is designed and analysed to fit the design specification. The experiment showed that the flux distribution of a magnet is good agreement of the given specification.

  • PDF

CRYSTAL ORIENTATION OF ELECTROLESS COPPER AND ELECTRODEPOSITED NICKEL FILMS ON THE MAGNETS

  • Chiba, Atsushi;Kobayashi, Katsuyoshi;Miyazaki, Hiroki.;Yoshihara, Sachio;Wu, Wen-Chang
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.372-376
    • /
    • 1999
  • The deposited Cu film on the ferrite magnet was more deposited comparing with that on the plastic magnet. The Cu film became thicker on the S pole comparing with that on the N pole in the both of magnets. The thickness and texture coefficient of deposited copper film affected with direction of line of magnetic force. The difference of pole had little or no effect to the texture coefficient of deposited nickel film. The reaction rate on ferrite magnet and S pole was faster comparing with that on plastic magnet and N pole.

  • PDF

A study on the fracture toughness evaluating method for cryogenic structural material (극저온용 구조재료의 파괴인성평가법에 관한 연구)

  • Kwon, Il-Hyun;Chung, Se-Hi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.64-72
    • /
    • 1998
  • This paper was undertaken to develop the fracture toughness testing method using small and single specimen compared to the conventional method in evaluating elastic-plastic fracture toughness of the superconducting magnet structural material at cryogenic temperature. The elastic-plastic fracture toughness test was conducted by using the unloading compliance method recommended by ASTM E813-89 to accomplish the above purpose. And, the 20% side-grooved 0.5TCT and 1TCT specimens were used to evaluate the fracture toughness by using as possible as miniaturized CT specimen. The unloading compliance method was a very useful method in evaluating elastic-plastic fracture toughness at cryogenic temperature. It could be taken valid fracture toughness values by using 20% side-grooved 0.5TCT specimen recommended by ASTM E813-89.

The Fabrication of 4 Poles Anisotropic Plastic Magnets (4극 이방성 플라스틱자석의 제조)

  • 정왕일;진성빈;문현욱;신용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.125-127
    • /
    • 1996
  • This paper deals with the fabrication of 4 poles anisotropic Sr·ferrite plastic magnets. After Polyamide6 and polyamlde12 are kneaded respectively with Sr·ferrite powder, silane coupling and calcium stearate of lwt% are added for coating and pelleting. The pelleted specimen are injection-moulded under the magnetic field using 4 poles mould. For 4 poles anisotropic Sr·ferrite plastic magnets with polyamide6 as a binder, the surface magnetic flux density distribution is +943.8∼-943.87kG and the deviation is 5.2%, where as with polyamide12, the distribution is +1040.9∼-1040.9kG and the deviation is 5.4%. It shows that both of the magnet distributions are stable. As the results of the experiments, we find 4 poles anisotropic Sr·ferrite magnets have good properties as the materials appropriate for manufacturing magnet type synchronous motors.

  • PDF

A Case of Postoperative Silicone Magnet Compression Treatment of Pseudocyst in the Ear (귀에 발생한 가성낭종의 수술 후 실리콘 자석 압박 치료 사례 1예)

  • Seol, Seong Hoon;Chung, Chan Min;Park, Myong Chul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.38 no.1
    • /
    • pp.69-74
    • /
    • 2022
  • Endochondral pseudocyst of the ear is a rare, benign, non-inflammatory cystic disease. It is known that there are a variety of treatment methods for pseudocyst, which is mainly common in the scaphoid or triangular fossa of the ear. Pseudocyst formation is prevalent in the residual cavity of the ear. So, to prevent a recurrence, a surgical approach is also required, but management through compression is necessary after surgery. Applying a cube magnet to the lesion to press provides patient convenience and facilitates continuous management.

A Study on the Fabrication for High Quality Ferrite Plastic Magnets (고품위 페라이트 본드자석 제조에 관한 연구)

  • 신용진;문형욱;진성빈;정왕일
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.440-446
    • /
    • 1997
  • This research has been performed for the fabrication of high quality ferrite plastic magnet. The magnetic properties of S $r_{5.9}$F $e_2$ $O_3$ ferrite bonded magnets by injection moulding with a variety of applied magnetic field were investigated. 0.3wt% CaCO3, 0.2wt% $SiO_2$, 0.5wt% $Al_2$ $O_3$and 0.5wt% N $a_2$ $SiO_3$are added in order to improve the magnetic properties of Sr-ferrite plastic magnets during the powder fabrication. For carbon coating on chemical compound specimen, 5wt% polyvinyl alcohol is added, and then calcinated under $N_2$ environment of 12$25^{\circ}C$. The particle size is distributed from 0.9~1.2${\mu}{\textrm}{m}$ which approximates to the single domain. The obtained Sr ferrite powder is well mixed with silane coupling and calcium stearate of 1wt%. Nest, the specimen is pelleted after kneading each of them with polyamidel2 as a binder. When the temperature of injection and mould were 25$0^{\circ}C$ and 8$0^{\circ}C$ respectively at injection pressure of 200kgf/$\textrm{cm}^2$, the degree of orientation was 85.3% under the applied magnetic field of 12kOe. As the results, when the packing density of Sr ferrite powder was 90wt%, the magnetic properties of Sr ferrite bonded magnet were follows : $_{B}$ $H_{c}$=2.41kOe, Br=3.1kG, (BH)$_{max}$=2.21MgOe. Especially, the Sr-ferrite bonded magnet with 10wt% N $d_2$F $e_{14}$B additive were as follows : $_{B}$ $H_{c}$=2.57kOe, Br=3.14kG and (BH)$_{max}$=2.39MGOe.GOe.GOe.GOe.e.

  • PDF

Fluroscopic Removal of the Foreign Bodies from Gastroesophagus Using the Magnet (자석을 이용한 식도 위 이물 제거술)

  • Park, Youn-Joon;Lee, Doo-Sun
    • Advances in pediatric surgery
    • /
    • v.13 no.2
    • /
    • pp.112-118
    • /
    • 2007
  • Ingested foreign bodies are common occurrences in the pediatric population. From October 2002 to April 2006, eight patients (6 male, mean age: $30.9{\pm}14.4$ months, range: 7~45 months) who had ingested metallic foreign bodies, such as bar magnets, coin-type magnets, screws, metal beads, and disk batteries, were selected for foreign body removal using a magnetic device under floroscopic control. A 1-cm-long cylindrical magnet (6 mm in diameter) was placed at the end of a 150-cm-long plastic tube from an IV set. The magnet was passed through the mouth into the stomach. Under fluoroscopic control, the magnet was maneuvered so that it attached to the metallic foreign bodies. The forgeign body was then easily removed by retracting the magnet with the metallic object attached. This procedure was successful in six patients of 8 patients. This procedure is a minimally-invasive and may avoid the use of anesthesics, endoscopy or surgery.

  • PDF

A Leak Inspection Automation System for Sealed SUS CAN Rotor (밀폐형 SUS CAN Rotor를 위한 Leak 검사 자동화 시스템)

  • Choi, Chang-min;Seo, Su-min;Shin, Gi-su;Park, Jong-won;Jung, Yeon-seok;Yoo, Nam-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.406-408
    • /
    • 2019
  • The motor applied to electric water pump used in automobiles is the canned type motor structure. The rotor, which is the driving component of the motor, is located in the bulkhead structure of the plastic injection molding, and rotates while immersed in the antifreeze. Plastic Injection Stator is placed on the outside of the bulkhead structure so that the rotor can rotate. The configuration of the rotor consists of magnet, core and shaft. In the case of magnet and core, it is very important to keep the parts sealed because it is a material that is corroded by moisture. When mounted on a vehicle, it must be capable of driving at $120^{\circ}C$ ambient conditions and should not leak under pressure of 1 bar or more. In this paper, we designed and implemented a Leak inspection automation system using helium to check the defects of the electric water pump developed satisfying this condition.

  • PDF

Study of micro-plastics separation from sea water with electro-magnetic force

  • Nomura, Naoki;Mishima, Fumihito;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.10-13
    • /
    • 2021
  • The method of removing micro-plastics from sea water has been developed using electro-magnetic force. Plastics are difficult to decompose and put a great load on the marine environment. Especially a plastic with a size of 5 mm or less is defined as micro-plastic and are carried by ocean currents over long distances, causing global pollution. These are not easily decomposed in the natural environment. The Lorentz force was generated in simulated sea water and its reaction force was applied to the micro-plastic to control their motion. Lorentz force was generated downward and the reaction force to the plastics was upward. The plastic used in the experiment was polystyrene with a diameter of 6 mm, and the density was 1.07 g/cm3. The polystyrene sphere levitated at the current density of 0.83 A/cm2 and the external field of 0.87T. The particle trajectory calculation was also made to design separation system using superconducting magnet.