• Title/Summary/Keyword: plant requirements

Search Result 472, Processing Time 0.031 seconds

Energy Analysis in CO2 Membrane Separation Process via Heat Integration (열통합 기법을 통한 이산화탄소 막 분리공정 에너지 해석)

  • Kim, Seong Hun;Kim, Tae Yong;Kim, Beom Seok;Cho, Hyun-Jun;Yeo, Yeong Koo
    • Plant Journal
    • /
    • v.12 no.2
    • /
    • pp.24-30
    • /
    • 2016
  • The membrane separation processes have received attention due to advantages such as compactness, modularity, ease of installation, flexibility of operation, lower capital cost and lower energy consumption. In this study, we evaluated accuracy of cross-flow, co-current and counter-current models. With the most accurate model, we identified the operating conditions of the two-stage membrane separation and examined the effects of permeance and selectivity of the membrane by simulation. Futhermore, power requirements and operating cost savings due to the introduction of the heat exchanger were investigated by applying heat exchanger network synthesis technique in the two-stage membrane separation using vapor sweep.

  • PDF

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

Development of TDMA-Based Protocol for Safety Networks in Nuclear Power Plants (원전 안전통신망을 위한 TDMA 기반의 프로토콜 개발)

  • Kim, Dong-Hoon;Park, Sung-Woo;Kim, Jung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.303-312
    • /
    • 2006
  • This paper proposes the architecture and protocol of a data communication network for the safety system in nuclear power plants. First, we establish four design criteria with respect to determinability, reliability, separation and isolation, and verification/validation. Next we construct the architecture of the safety network for the following systems: PPS (Plant Protection System), ESF-CCS (Engineered Safety Features-Component Control System) and CPCS (Core Protection Calculator System). The safety network consists of 12 sub-networks and takes the form of a hierarchical star. Among 163 communication nodes are about 1600 origin-destination (OD) pairs created on their traffic demands. The OD pairs are allowed to exchange data only during the pre-assigned time slots. Finally, the communication protocol is designed in consideration of design factors for the safety network. The design factors include a network topology of star, fiber-optic transmission media, synchronous data transfer mode, point-to-point link configuration, and a periodic transmission schedule etc. The resulting protocol is the modification of IEEE 802.15.4 (LR-WPAN) MAC combined with IEEE 802.3 (Fast Ethernet) PHY. The MAC layer of IEEE 802.15.4 is simplified by eliminating some unnecessary (unctions. Most importantly, the optional TDMA-like scheme called the guaranteed time slot (GTS) is changed to be mandatory to guarantee the periodic data transfer. The proposed protocol is formally specified using the SDL. By performing simulations and validations using Telelogic Tau SDL Suite, we find that the proposed safety protocol fits well with the characteristics and the requirements of the safety system in nuclear power plants.

Effect of Growth Conditions on the Biomass and Lipid Production of Euglena gracilis Cells Raised in Mixotrophic Culture (Mixotrophic 배양조건에 따른 Euglena gracilis의 성장과 지질에 미치는 영향)

  • Jeong, U-Cheol;Choi, Jong-Kuk;Kang, Chang-Min;Choi, Byeong-Dae;Kang, Seok-Joong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.1
    • /
    • pp.30-37
    • /
    • 2016
  • Microalgae are functional foods because they contain special anti-aging inhibitors and other functional components, such as ecosapentaenoic acid (EPA), docosahexaenoic acid (DHA), and omega-3 polyunsaturated fatty acids. Many of these functional dietary components are absent in animals and terrestrial plants. Thus, microalgae are widely utilized in human functional foods and in the feed provided to farmed fish and terrestrial livestock. Many marine organisms consume microalgae, often because they are in an appropriate portion of the cell size spectrum, but also because of their nutritional content. The nutritional requirements of marine organisms differ from those of terrestrial animals. After hatching, marine animals need small live forage species that have high omega-3 polyunsaturated fatty acid contents, including EPA and DHA. Euglena cells have both plant and animal characteristics; they are motile, elliptical in shape, 15-500 μm in diameter, and have a valuable nutritional content. Mixotrophic cell cultivation provided the best growth rates and nutritional content. Diverse carbon (fructose, lactose, glucose, maltose and sucrose) and nitrogen (tryptone, peptone, yeast extract, urea and sodium glutamate) supported the growth of microalgae with high lipid contents. We found that the best carbon and nitrogen sources for the production of high quality Euglena cells were glucose (10 g L–1) and sodium glutamate (1.0 g L–1), respectively.

A Study on the Application of Thermal Insulation Composite Frame for Welding in Enclosed Space (밀폐 공간에서 용접작업을 위한 단열 복합재 프레임의 설계 적용 연구)

  • Lee, Jae-Youl;Jeong, Kwang-Woo;Hong, Sung-Ho;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.227-237
    • /
    • 2018
  • In this paper, the design application for the lightweight and insulation of the manipulator of the mobile welding robot for the closed/narrow space is presented. A variety of robotic platforms have been developed for weld-worker using a welding robot outside a workpiece for welding work in a complex and narrow space such as a ship or an offshore plant. Normally, The development process of robots consists of machine development, electronic device development, control algorithm development and integration verification considering application environment and requirements. In order to develop the robustness of the welding robot, the lightweight design of the robot manipulator considering the environmental conditions was performed in the basic design of the robot platform. Also, The results of the robot selection and validation, analysis and testing for the insulation performance and cooling performance and the results of the research are shown.

Optimum Lens Organization and System Set-up for 2-Dimensional Imaging of Biophoton (생물 광자의 이차원 영상을 위한 렌즈계 최적화와 장치 구성)

  • Yi Seung-Ho;Shim Seong-Bo;Kim Jai-Soon;Yang Joon-Mo;Lee Changhoon;Soh Kwang-Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.519-526
    • /
    • 2004
  • We developed a 2-D imaging system to detect ultra weak biophoton by using a high sensitive fast CCD camera. We installed an illumination apparatus to generate delayed luminescence from plant leaves. Shutters at the illumination system and detector were synchronized to each other. The lens system of the CCD camera was newly designed to accommodate the specific requirements to enhance the collection efficiency for biophoton. Based on the lens simulation, commercial lenses were chose for the lens system. All the equipment was installed in a multi-purpose dark box and the delayed luminescence of Euonymus japonica was successfully acquired.

Simulation of Effects of Swine Manure Application Rates on Nitrate Concentration in Runoff, Indiana, USA

  • Lim, Kyoung-Jae;Engel, Bernard A.;Jeon, Ji-Hong;Jones, Don;Sutton, Alan L.;Ok, Yang-Sik;Kim, Ki-Sung;Choi, Joong-Dae
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.1
    • /
    • pp.38-46
    • /
    • 2009
  • Livestock manure is an important source of nutrients for crop production. However, farmers typically do not know the exact nutrient values for livestock manure. In many instances, manure has been viewed as a waste, and as a result it is applied close to the source resulting in over application of nutrients. Thus, the goal of nutrient application has often been applied to reduce the application expense rather than to maximize crop income. This results in wasted money and potentially negative impacts on water quality. Several livestock manure management scenarios were created based on agronomic nutrient requirements using the Utilization of Animal Manure as a Plant Nutrient (AMANURE) software to investigate water quality impacts with the National Agricultural Pesticide Risk Analysis (NAPRA) WWW modeling system. Application of manure at agronomic rates can result in high nitrate-nitrogen losses for some soil types, especially when applied in late fall. The application of manure at an agronomic rate does not necessarily equate to adequate water quality protection, and farmers must take care applying manure at agronomic rates, because nitrate-nitrogen loss potential varies spatially and temporarily. Nutrient loss probability maps for Indiana at 5%, 10%, 25%, and 50% values were created to demonstrate potential water quality impacts when livestock manure is applied to cropland at agronomic rates. The NAPRA WWW system coupled with AMANURE can be used to identify site-specific livestock manure management plans that are environmentally sound and agronomically appropriate.

Development of A Machine-to-Machine (M2M)-based Public Restroom Management System (사물지능통신(M2M)을 이용한 공중화장실 관리시스템의 개발)

  • Kim, Jun Yeob;Ahn, Dae Gun;Bae, Byoung Wook;Choi, Yong Gu;Kang, Chang Soon
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.12
    • /
    • pp.1473-1483
    • /
    • 2014
  • A public restroom is different from a household toilet in terms of location and a large number of sharing users. In addition, public restroom is usually messy and filthy. Recently, public toilet tends to be clearly managed than before, but it still has hygienic and clear problems. In this paper, we propose a machine-to-machine (M2M)-based public restroom management system to solve these problems, in which the system with a wireless communication device sends the status information of the toilet, such as blockage or trouble detected by a sensor, to the manager of the restroom at a remote location. In particular, we have developed a prototype management system for public restroom taking into account several system requirements, and verified the basic operations and performance of the management system. With the application of the system to public facilities, it will furnish users with more pleasant environments by restroom administrators who can respond effectively to the troubled toilet.

Evaluation of Load Capacity and Toughness of Porous Concrete Blocks Reinforced with GFRP Bars (GFRP 보강 다공성 콘크리트 블록의 내력 및 인성 평가)

  • Jung, Seung-Bae;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.403-409
    • /
    • 2017
  • In this study, mix proportioning of porous concrete with compressive strength and porosity exceeding 3MPa and 30%, respectively, was examined and then load capacity and flexural toughness of the porous concrete block were evaluated according to the different arrangements of the GFRP bars. To achieve the designed requirements of porous concrete, it can be recommended that water-to-cement ratio and cement-to-coarse aggregate ratio are 25% and 20%, respectively, under the aggregate particle distribution of 15~20mm. The failure mode of porous concrete blocks reinforced with GFRP bars was governed by shear cracks. As a result, very few flexural resistance of the GFRP was expected. However, the enhanced shear strength of porous concrete due to the dowel action of the GFRP bars increased the load capacity and toughness of the blocks. The porous concrete blocks reinforced with one GFRP bar at each compressive and tensile regions had 2.1 times higher load capacity than the companion non-reinforced block and exhibited a high ductile behavior with the ultimate toughness index ($I_{30}$) of 43.4.

Study of Post-Fire Safe-Shutdown Analysis of a CANDU Main Control Room based on NEI 00-01 Methodology (NEI 방법론을 적용한 중수로 주제어실의 화재안전정지분석에 관한 연구)

  • Kim, In-Hwan;Lim, Heok-Soon;Bae, Yeon-Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.20-26
    • /
    • 2016
  • When the fire takes place in Nuclear Powr Plants(NPPs), the reactor should achieve and maintain safe shut-down conditions and minimize the radioactive material released to the environment. The U.S. Nuclear Regulatory Commission (NRC) has issued numerous generic communications related to fire protection over the past 20 years, after it issued its requirements in the Fire Protection Rule set forth in Title 10, Section 50.48 of the Code of Federal Regulations (10 CFR 50.48) and Appendix R to the 10 CFR 50. The and Nuclear Energy Institute (NEI) has developed a Methodology for Risk Informed Fire Safe-Shutdown Analysis, which is related to the Deterministic Method for Multiple Spurious Operations solutions. The aim of this study was to identify, achieve, and maintain Post-Fire Safe-Shutdown of the Main Control Room (MCR) of the CANDU reactor, even though one train of the multiple Safety Structures, Systems, and Components (SCCs) fail by the technical specification and analysis method.