Abstract
Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.
Keywords
Green Roof System; Root Proofing Materials; Environmental Performance Index; Resistance To Root Penetration;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Oh SK, Kwak KS, Seon YS, Kwon SW, A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs, Journal of the Korea Institute of Building Construction 2007;7(1):79-84.5   과학기술학회마을   DOI   ScienceOn
2 Oh SK, Choi SK, Choi SM, An Experimental Study on the Root Barrier Design of Joint pf Panel Type Waterproofing Method by Considering the Growth Diagnosis of Root, Journal of the Architectural Institute of Korea 2009;25(9):117-124.
3 CHO IK, A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System [MD dissertation], Seoul: Seoul Nation University of Science & Technology; 2007.
4 Seon YS, A Study on How structural Load Affects the Physical Property Change of the Non-exposed Water-proof Membrane Layer [MD dissertation], Seoul: Seoul Nation University of Science & Technology; 2007.
5 Kwon SW, Jo IG, Bae KS, Oh SK, The Necessity Analysis of Development Waterproofing Materials and Methods of Construction Technologies for Green Roofs, Journal of the Korea Institute of Building Construction 2004;4(1):111-118.   과학기술학회마을   DOI   ScienceOn
6 Oh SK, Kwon KJ, Kwon SW, A Technical Point to be Considered Friendly Environment Greenng System in Architectural Plan, Journal of the Architectural Institute of Korea 2008;(5):59-63.
7 Oh SK, Kim YG, Shin JJ, Kim HS, K SW, A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System, Journal of the Architectural Institute of Korea 2009;25(11):95-104.   과학기술학회마을