• Title/Summary/Keyword: plant construction

Search Result 2,250, Processing Time 0.025 seconds

The Comparative Study of Flora around the Geumgang Area (금강 수계의 식물상 비교 연구)

  • Kim, Young-Hyun;Park, Jeong-Mi;Jang, Chang-Gee
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.2
    • /
    • pp.216-229
    • /
    • 2009
  • The flora of vascular plants in the Geumgang area (Mt. Guryongsan, Mt. Jeonwolsan, Mt. Samasan, Mt. Yongmeorisan and Mt. Hamrasan) was investigated to suggest strategies for conservation. This study was performed from May 2007 to April 2008, with total 17 times. The Korean endemic species, legally protected species and species to threaten domestic ecosystem species to threaten were grasped on this study. The flora consists of 334 taxa, 86 families 246 genera 297 species 34 varieies and 3 forms in total results from 5 sites in this study. Korean endemic species were confirmed 8 taxa. No rare and endangered species were found in this study. The 2 taxa of the fourth grade of specially designated plants announced the Ministry of Environment were investigated and 8 taxa of the third grade were confirmed. In totally, 24 taxa that are specially designated plants announced the Ministry of Environment including the first and the second grade taxa. 25 taxa of alien naturalized plants were confirmed. The degree of destroy of forest vegetation and reduction of plant diversity in the midstream of Geumgang were in proceeding by construction of multifunctional administrative city and cultivation. It is needed to set up strategies for conservation forest vegetation in this study area.

A Study on the Method for Ecological Restoration on Abandoned Concrete-paved Road - Focused on the Experimental Construction Site in Young Dong Province of GyungBu Express Highway(227.24~229.04km) - (콘크리트 폐도의 생태복원 방안 모색에 관한 연구 - 경부선 영동군 황간지역 시험시공지를 중심으로(경부고속도로 227.24~229.04km 지점) -)

  • Kim, Nam Choon;Ann, Phil Gun;No, Su Dae;Kim, Do Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.4
    • /
    • pp.119-132
    • /
    • 2012
  • The unmanaged abandoned concrete roads are vulnerable toward the issues on soil and water pollution, which requires flexible managing method such as eco-corridor after the process of ecological restoration. Among various alternations of abandoned concrete-paved roads, ecological restoration technique may be the most suitable method in sites including high quality of natural environment. Therefore, as in Young dong province, GyungBu express highway (227.24~229.04km), which is near to Hwang-gan IC, the survey to measure its effect of soil under the paving and water pollution by abandoned concrete roads was discussed. Then, the restoration method of plantings of landscape trees and hydro-seeding methods of artificial soil media was appraised through consecutive monitoring. The soil adequacy analysis shows lower percentage of heavy metal substance in each depth level compared to standard limit stated by the Ministry of Environment, along with low concerns raised after the analysis on heavy metal content of the spilled water on the concrete roads. Meanwhile, Korean Weigela (Weigela subsessilis L.H. Baily) was found to be withered in small-scale landscape trees planting sites. Among the seeding plants. the family of leguminosae, Silene armeria, Dendranthema boreale, Caryopteris incana and Aster yomena show good establishment results. Overall studies on planting of small and large landscape trees, planting method of container plants, planting method of ground cover plants, and germination and development trend of seeding plants of the experimental restoration site on abandoned concrete roads are revealing specific trends in the way landscape woody plants establishment and growth. Finally, this study suggests further studies and survey on varied plant restoration methods on abandoned concrete-roads for developed design guidelines of their methods.

Construction of a Microsatellite DNA Profile Database for Pear Cultivars and Germplasm (배 품종 및 유전자원에 대한 Microsatellite DNA 프로파일 데이터베이스 구축)

  • Hong, Jee-Hwa;Shim, Eun-Jo;Kwon, Yong-Sham
    • Horticultural Science & Technology
    • /
    • v.35 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • A DNA profile database was constructed to investigate the genetic relatedness of 72 germplasm samples of Pyrus and related cultivars using microsatellite markers. Three P. pyrifolia, four P. commus, and one P. betulifolia cultivars with different morphological traits were screened using 387 pairs of microsatellite primers. A core set of 11 primer pairs was selected to obtain 133 polymorphic amplified fragments meeting three criteria: high polymorphism information contents (PIC), high repeatability, and distinct allele patterns. The number of alleles per locus ranged between 4 and 22. Average PIC was 0.743 (range: 0.557 - 0.879). Cluster analysis using the unweighted pair - group method with arithmetical average (UPGMA) separated the 72 pear cultivars and germplasm samples into four major groups: Chinese, European pears, and a cluster of 55 Asian pears that could be reclassify into two subcluster, I - $1^{st}$ and II - $2^{nd}$, according to pedigree information. Almost all of the cultivars were discriminated by 11 microsatellite marker genotypes. The microsatellite DNA profile database may be utilized as tool to verify distinctness, uniformity, and stability between candidate cultivar, and to verify in the distinctness of existing cultivars.

A development of integrated water-quality measurement system (통합 수질계측 시스템 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • The quality of tap water on the whole water-supply system, from a large filtration plant to a private faucet, has to be guaranteed the standards of drinking water. At this point in time, however, the supply process of the tap water has not been monitored and managed scientifically. The piped water, especially the most small-scale reservoirs(underground or overhead type) are always exposed to various contaminations and impurities. Recently monitoring systems of water-quality were spread on some large filtration plants or distributing reservoirs. In particular, the water quality monitoring method using the internet is adopted into some local government whose inhabitants can check up the water quality anytime and anywhere. The construction of this system that has to apply a large scale needs, and has a limitation on the small water-supply system, such as apartments, public facilities and small-scale underground or overhead reservoirs. In this work, we suggest the integration system of individual water-quality sensor modules that have a low price. By using the developed integration system and monitoring program operated on the internet, the system managers of reservoirs can monitor and manage water-quality characteristic values of drinking water in online. Since the proposed system was modularized, the system can be applied easily into various reservoirs with a low cost and regardless of its scale, small or large.

  • PDF

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

CLINICOSTATISTICAL ANALYSIS OF SURGICAL FINDINGS IN CHRONIC OTITIS MEDIA (만성 중이염의 수술시 소견에 대한 임상통계적 관찰)

  • 최덕주;전병훈;민원식;함태영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1987.05a
    • /
    • pp.6-6
    • /
    • 1987
  • 만성중이염은 현재 그 빈도가 줄어드는 추세에 있으나 아직도 이과 영역에서 큰 비중을 차지하는 질환이다. 또한 청력개선, 정상구조의 보존, 병변 제거의 목적을 위하여 대부분 수술적 요법이 필요하게 된다. 이에 저자들은 본 병원에서 시행한 만성 중이염 451예, 남자 238예, 여자 213예. 진주종성 중이염 170예, 비진주종성 중이염 273예에 대한 수술시 소견에 대한 임상 통계적 관찰을 한 바, 다음과 같은 결과를 얻었다. 1) 관찰대상을 술식별로 분류하면 진주종성 중이염과 비진주종성 중이염의 비가 $\circled1$ Myningoplasty ; 19.1% : 0%, $\circled2$ Tympanoplasty without mastoidectomy ; 34.5% : 14.4%, $\circled3$ Tympanoplasty with mastoidectomy ; 3.0% :12.1% 이었다. 2) 고막천공부위는, 진주종성 중이염과 비진주종성 중이염의 비가 변연부천공이 10.1% : 5.5%, 상고실천공이 38.8% : 1.4%, 중심부천증이 12.9% : 47.3%, 전천공이 32.5% : 39.6%, 고막유착이 5.6% : 6.2% 을 보였다. 3) 이소골의 상태는 진주종성중이염과 비진주종성 중이염의 비가, 모든 이소골의 손실은 26.6% : 4.3%, 모든 이소골이 정상에 가까운 예는 16.6% : 69.3%, 가장 병변이 심했던 침골 이상은 76.9% : 24.8% 를 보였다. 4) 중이강 점막소견은 진주종성 중이염과 비진주종성 중이염의 비가, 정상에 가까운 예가 16.7% : 47.0%, 병적 소견을 보인 예가 83.3% : 53.0% 이었다. 5) 진주종성 중이염과, 비진주종성 중이염에서의 안면신경관노출은 2.2% : 0.3%, 뇌막노출은 9.5% : 2.9%, 횡정맥동노출은 5.0% : 1.1%, 미로누공은 1.7% : 0% 이었다.lant, engineering service business can be said "The Software of Total Industry." Engineering service is what is called a higher business which offers specialized engineering know-how and experience. Engineering service compaines offer Its specialized knowledge and experience to government, industry and commerce. Whether the task is to modernize plant equipment, to design a building or to manage construction, an engineering company will develop and implement the most appropriate and cost effective solution. Clients use the engineering service of firm knowing that the engineer′s professional judgement is not influenced or biased by other commercial affiliations. While benefiting from the diverse experience that professional engineers can apply to a specific problem, government and industry also reduce the need for permanent in-house engineering staff. Engineering firms may be specialized or multi-disciplinary.도말표본에서와 같이 제 14 일 이전에는 호중구가, 그 이후에는 단핵구가 주종을 이루었다.>18.9dB

  • PDF

Experimental Studies on Bond and Splice Performance of Splice Sleeve for Connecting Rebar (철근연결용 스플라이스 슬리브의 이음 및 부착성능에 대한 실험적 연구)

  • Kang, Duk Man;Park, Yong Gul;Lee, Hyeon Gi;Moon, Do Young
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.257-264
    • /
    • 2017
  • The PC (Precast Concrete) construction method is a technique where concrete members that have been produced in a plant are constructed on site. Thus, continuity and secure integration of a structure that can be obtained by connecting rebars at splicing joint for PC members are the main areas of concern for this method. To evaluate the splicing and bonding performance according to application of a splice sleeve for connecting rebar in this research study, the diameter of rebar, development length, grouting strength etc. were set as variables. The performance and stiffness of splicing according to the development length of grout strength were measured and evaluated. In addition, by conducting comparative analysis on each of the variables, the factors that affected the splice sleeve for connecting rebar were discussed. The results confirmed that the strength and stiffness of the splice sleeve for connecting rebar were significantly affected by the development length while the increase in performance according to grout strength was not as significant.

Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source (지역난방용 중온수 열원 유기랭킨사이클 성능 특성)

  • Park, Woo-Jin;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2016
  • It is becoming increasingly important to make use of alternative energy source. because It is not able to rely on only fossil fuel for the recent increasing demand of energy consumption. With this situation, lots of studies for utilizing low grade energy such as industrial waste heat, solar energy, and geothermal energy have been conducted. The aim of this study is to predict the operation characteristics of working fluid by using performance analysis program (ThermoFlex) through the system analysis which is not mixing district return water but using ORC(Organic Rankine Cycle, hereinafter ORC) as a downstream cycle when accumulating district heating (hereinafter DH). In this study, We conducted the performance analysis for the case which has the district heating water temperature($120^{\circ}C$) and Flow rate of $163m^3/h$ (including District Heating return water flow), and examined several working fluid which is proper to this temperature. The case using R245fa (which is the best-case) showed 269.2kW power output, 6.37% efficiency. Additionally, Cut down on fuel was expected because of the boiler inlet temperature increase by being Formed $57.3{\sim}85^{\circ}C$ in a temperature of district heating return water, depending on a pressure change of a condenser in ORC system.

  • PDF

Prediction of the Thermal Efficiency at Increased Pressure Ratio in an F-Class Gas Turbine with Operating Data (F급 가스터빈의 압력비 증가 시 운전데이터를 이용한 열효율 변동 예측)

  • Park, Joon-Chul;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-sun;Lee, Jae Heon
    • Plant Journal
    • /
    • v.10 no.3
    • /
    • pp.39-44
    • /
    • 2014
  • The gas turbine thermal efficiency has been predicted when the compressor pressure ratio increases from the previously set 13.5. Thermal efficiency has been predicted from 14.2 up to 18.2 at which the turbine work reaches its maximum value on the assumption that isentropic efficiency of the compressor and the turbine are constant using the operating data at the pressure ratio of 13.5. 35.11% of thermal efficiency has been acquired by the performance test when the pressure ratio increased to 16.2 since replacing the compressor low pressure stages. It's been approved that predicting thermal efficiency using the operating data at the pressure ratio of 13.5 is useful within 7.86% of tolerance as the figure measured by the performance test.

  • PDF

Development of Composite Sensing Technology Using Internet of Things (IoT) for LID Facility Management (LID 시설 관리를 위한 사물인터넷(IoT) 활용 복합 센싱 적용기술 개발)

  • Lee, Seungjae;Jeon, Minsu;Lee, Jungmin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.312-320
    • /
    • 2020
  • Various LIDs with natural water circulation function are applied to reduce urban environmental problems and environmental impact of development projects. However, excessive Infiltration and evaporation of LID facilities dry the LID internal soil, thus reducing plant and microbial activity and reducing environmental re duction ability. The purpose of this study was to develop a real-time measurement system with complex sensors to derive the management plan of LID facilities. The test of measurable sensors and Internet of Things (IoT) application was conducted in artificial wetlands shaped in acrylic boxes. The applied sensors were intended to be built at a low cost considering the distributed LID and were based on Arduino and Raspberry Pi, which are relatively inexpensive and commercialized. In addition, the goal was to develop complex sensor measurements to analyze the current state o f LID facilities and the effects of maintenance and abnormal weather conditions. Sensors are required to measure wind direction, wind speed, rainfall, carbon dioxide, Micro-dust, temperature and humidity, acidity, and location information in real time. Data collection devices, storage server programs, and operation programs for PC and mobile devices were developed to collect, transmit and check the results of measured data from applied sensors. The measurements obtained through each sensor are passed through the Wifi module to the management server and stored on the database server in real time. Analysis of the four-month measurement result values conducted in this study confirmed the stability and applicability of ICT technology application to LID facilities. Real-time measured values are found to be able to utilize big data to evaluate the functions of LID facilities and derive maintenance measures.