• Title/Summary/Keyword: pitch treatment

Search Result 202, Processing Time 0.028 seconds

Preparation and properties of antibacterial activated carbon fiber (항균성 탄소섬유의 제조와 특성)

  • 오원춘;김범수;임창성;장원철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.4
    • /
    • pp.165-171
    • /
    • 2002
  • The study on the adsorption, the surface properties and the antibacterial effects of the metal-treated pitch based activated carbon fibers was carried out. From the adsorption studies on the series of metal-treated activated carbon fiber, the specific surface areas of the metal treated activated carbon fiber obtained from BET equation were in the range of 113.2~1574 $m^2$/g for the Ag-ACFs. And that of Cu treated ACF are distributed to 688.2-887.8 $\m^2$/g. And, the specific surface areas of the Ni-treated pitch based ACFs were in the range of 692.6~895.2 $\m^2$/g. From the ${\alpha}_s$- method, 0.06~1.1 cm^3/g of the micropore volumes were obtained from Ag-ACFs. And, 0.1~0.2 cm^3/ and 0.2~0.6 cm^3/g of the micropore volumes were obtained from Cu and Ni-ACFs, respectively. And, from the SEM morphology results, it was observed that the surface of activated carbon fiber are partially blocked and coated by metal after the treatment. Finally, from the antibacterial effects of metal-treated activated carbon fiber against E. coli, the areas of antibacterial effect become larger with the increase in mole ratio of metal treated. And, from the antibacterial effects using Shake flask method against E. coli, the percentage of the effects was 92.5~100 % and the antibacterial effect was increased with the increase in mole concentration of metal treated.

Effect of E-beam Radiation with Acid Drenching on Surface Properties of Pitch-based Carbon Fibers (산 담지 전자선 조사가 피치계 탄소섬유의 표면특성에 미치는 영향)

  • Jung, Min-Jung;Park, Mi-Seon;Lee, Sangmin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.27 no.3
    • /
    • pp.319-324
    • /
    • 2016
  • In this study, pitch-based carbon fibers in the acid were radiated with an electron beam to modify their surface, and surface changes were investigated according to each treatment conditions. Nitric acid and hydrogen peroxide were used as a drenched acidic solution and an electron beam dose was set to 200 and 400 kGy. The use of nitric acid introduced more oxygen functional groups on carbon fiber surfaces than that of using hydrogen peroxide, and also introduced nitrogen functional groups into the carbon fiber surface. In addition, oxygen functional groups introduced on carbon fiber surface increased as the electron beam dose increased due to the fact that the oxidizing material can be easily formed by e-beam radiation in nitric acid than the hydrogen peroxide, and also the higher energy electron beam dose can help forming more oxidizing materials. Moreover, the generation of C=O functional groups was favorable when using nitric acid because oxidizing C-OH functional groups to the C=O functional groups mainly occurred by $NO_2$ radicals generated by the electron beam radiation in a nitric acid solution.

Effects of Butorphanol on Behavior after Intestinal Anastomosis in Dogs (Butorphanol의 투여가 장문합술 후 개의 행동에 미치는 영향)

  • Koo Ja-min;Lee Hee-chun;Chang Hong-hee;Seong Yong-jeung;Lee Hyo-jong;Yeon Seong-chan
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.6-15
    • /
    • 2005
  • This study was performed to investigate non-invasive behavioral pain assessment of dogs after surgery, and the analgesic effects of butorphanol after intestinal anastomosis in dogs. In this study, five dogs in the Control Group were anesthetized, but did not undergo surgery. Five dogs in the Analgesic Group were undergone intestinal anastomosis and treated with butorphanol. Five dogs in the Non-analgesic Group were also undergone intestinal anastomosis without analgesic treatment. The dogs in the Analgesic Group received butorphanol (0.4 mg/kg, IM) before and immediately after operation, while dogs in Control and Non-analgesic Groups received isovolumetric doses of sterile saline. The behavior of dogs were videotaped for 400 mins after anesthesia, during which time a researcher interacted with the dog once per each 80 mins. At each interaction, the researcher recorded behavioral pain score, using University of Melbourne Pain Scale. Interactive and non-interactive behaviors were observed and quantitated by a single observer using focal continuous sampling method. Vocalizations were obtained during 400 mins after anesthesia, and duration of call, intensity, pitch, 1-4 Formant were analyzed. Surgery affected an increasing of pain score. During interactions with researcher, greeting behaviors were decreased after surgery. Differences between Analgesic group given analgesic or that given a placebo drug were readily understood using quantitative behavioral measurements and vocalization. Significant difference between Analgesic group given butorphanol or that the given placebo drug was apparent(p< 0.05).

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

Evaluation on the Usefulness of 6DoF Couch in V-MAT on Patients with Long length of Target (표적의 길이가 긴 환자의 용적회전변조 방사선치료 시 6DoF Couch의 유용성 평가)

  • Choi, Young Se;Park, Hyo Kuk;Kim, Se Young;Kim, Joo Ho;Lee, Sang Kyoo;Yoon, Jong Won;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.53-64
    • /
    • 2017
  • Purpose: To evaluate the usefulness of the $HexaPOD^{TM}$ evo RT system(6DoF couch) and the tendency of dose difference according to size of rotational direction error for volumetric rotational modulated radiotherapy(V-MAT) in patients with long target lengths. Therefore, it is suggested to recommend the need for rotational error correction. Materials and Methods: Ten patients with Esophagus cancer or Breast cancer including SCL treated with HexaPOD 6DoF(Six-Degree of Freedom) couch were included in this study. 6DoF couch was used to measure the difference in dose according to the rotation error in the directions of Rx(pitch), Ry(roll), and Rz(yaw). Each rotation error was applied. Positioning variation on x, y and z axis was verified and random variations were made by 6DoF couch with positioning variation. Modified DQA is conducted and point dose and gamma value are analyzed and compared. In addition, after applying the rotation error every $1^{\circ}$ to treatment plans of each target with a diameter of 3 cm, 5, 10, 15, and 20 cm respectively, gamma passing rate is being monitored by its aspect of change according to types and sizes of the target length and rotation error. Results: Mean error of the point dose and Gamma passing rate when the position variation was applied were $2.50{\pm}1.11%$ and $84.1{\pm}7.39%$ in the Rx direction, $2.36{\pm}1.16%$, and $81.0{\pm}8.49%$ in the Ry, $2.35{\pm}1.10%$ and $84.4{\pm}6.99%$ in the Rz direction, respectively. As a result of analysis on gamma passing rate according to types and sizes of the target length and rotation error, the gamma passing rate tended to decrease with increasing rotation error in the Rx and Rz directions except Ry direction. In particular, the lowest gamma passing rate (74.2 %) was in the case of $2.5^{\circ}$ rotation error in Rz direction of the target of 10 cm. Conclusion: The correction of the rotational error is needed for volumetric modulated radiotherapy of the treatment area with a long target length, and the use of 6DoF couch will improve the reproducibility of the patient position and the quality of the treatment.

  • PDF

The Results of the Endoscopic Decompression for the Treatment of Haglund's Disease (Haglund씨 병에서 시행한 내시경적 감압술의 결과)

  • Ahn, Su-Han;Cho, Hyung-Lae;Hong, Seong-Hwak;Wang, Tae-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.197-202
    • /
    • 2008
  • Purpose: Haglund's disease represents a painful heel caused by mechanically induced inflammation of the retrocalcaneal bursa and insertional Achilles tendinosis may coexist. Traditional open surgery can cause complications such as skin breakdown, painful scar and altered sensation around the heel. Endoscopic treatment offers the advantages that are related to minimally invasive procedure and we evaluate the clinical results and operative techniques of endoscopic decompression of retrocalcaneal space for Haglund's disease. Materials and Methods: Our retrospective study included seven heels in six consecutive patients for which nonoperative treatment had failed and endoscopic decompression was performed. The mean age was forty-one years (range, 28 to 53 years). All of the patients had typical complaints of inflammation of the retrocalcaneal bursa and Fowler-Philip angle of more than $75^{\circ}$ and positive parallel pitch lines were present on the lateral calcaneal radiograph. The endoscopic procedure consists of the resection of inflamed retrocalcaneal bursa and enough bone to prevent impingement of the bursa between the calcaneus and Achilles tendon. All patients were evaluated with radiologic angle, visual analogue scale (VAS) for pain and Ogilvie-Harris functional score. The mean follow-up was 18 months (range, 15 to 21 months). Results: The mean operation time was 61 minutes (range, 50 to 85 minutes). VAS for pain and Fowler-Philip angle were decreased from preoperative 8.7 and $82^{\circ}$ to postoperative 2.3 and $57^{\circ}$, respectively. One patient with ankylosing spondylitis had a fair result, 2 patients had good results and the remaining 3 patients had excellent results according to Ogilvie-Harris functional score. There were no surgical complications such as infection, Achilles tendon avulsion or abnormal heel sensation. Conclusion: The endoscopic decompression for Haglund's disease was demonstrated to have several advantages including low morbidity, allowance of functional rehabilitation, short recovery time and quick sports resumption. However a comparative study is needed to determine the value of endoscopic decompression and particular caution should be exerted for the enthesiopathy.

  • PDF

Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

  • Kim, Dae Gun;Jung, James J;Cho, Kwang Hwan;Ryu, Mi Ryeong;Moon, Seong Kwon;Bae, Sun Hyun;Ahn, Jae Ouk;Jung, Jae Hong
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.250-257
    • /
    • 2016
  • The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy. Thirty six-patients previously treated with IMRT technique were selected, and divided into two groups based on applied immobilization devices (FF versus LF). We performed a retrospective clinical analysis including the mean, systematic, random variation, 3D-error, and calculated the planning target volume (PTV) margin. In addition, a rotational error (angles, $^{\circ}$) for each patient was analyzed using the automatic image registration. The 3D-errors for the FF and the LF groups were 3.70 mm and 4.26 mm, respectively; the LF group value was 15.1% higher than in the FF group. The treatment margin in the ML, SI, and AP directions were 5.23 mm (6.08 mm), 4.64 mm (6.29 mm), 5.83 mm (8.69 mm) in the FF group (and the LF group), respectively, that the FF group was lower than in the LF group. The percentage in treatment fractions for the FF group (ant the LF group) in greater than 5 mm at ML, SI, and AP direction was 1.7% (3.6%), 3.3% (10.7%), and 5.0% (16.1%), respectively. Two different immobilization devices were affected the patient setup errors due to different fixed location in low extremity. The radiotherapy for the pelvic region by Tomotherapy should be considering variation for the rotational angles including Yaw and Pitch direction that incorrect setup error during the treatment. In addition the choice of an appropriate immobilization device is important because an unalterable rotation angle affects the setup error.

Photocatalytic effect for the carbon-coated TiO2 prepared from different heat treatment temperature (열처리 온도에 따라 제조된 탄소 코팅된 TiO2에 대한 광촉매 효과)

  • Chen, Ming-Liang;Bae, Jang-Soon;Oh, Won-Chun
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.460-467
    • /
    • 2006
  • Carbon-coated $TiO_2$ was prepared by $CCl_4$ solvent mixing method with different heat treatment temperature (HTT). Since the carbon layers derived from pitch on the $TiO_2$ particles were porous, the carbon-coated $TiO_2$ sample series showed a good adsorptivity and photo decomposition activity. The BET surface area was decreased by the increasing of the heat treatment temperature. The SEM results present to the characterization of surface texture on the carbon-coated $TiO_2$ sample and carbon distributions on the surfaces for all the materials used. The main elements of C, O and Ti were shown from EDX spectra. And the quantity of these elements is very rich in the samples. From XRD data, the pristine anatase peaks were observed in the X-ray diffraction patterns for the carbon-coated $TiO_2$ at the different HTTs. However, the rutile peaks were observed for the carbon-coated $TiO_2$ at HTT of 1073 K and 1123 K. Finally, the excellent photocatalytic activity of carbon-coated $TiO_2$ with UV-vis spectra between absorbance and time could be attributed to the homogeneous coated carbon on the external surface and structural phase transform, and the photocatalytic activity was decreased by the increasing of the HTT.

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.