• Title/Summary/Keyword: pipe house

Search Result 84, Processing Time 0.021 seconds

Development of a Gable-roofed Prefabricated Pipe-house for Improvement of Snow Endurance (내설성 향상을 위한 지붕형 조립식 파이프하우스의 개발)

  • Yang, In-Kyoo;Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.3
    • /
    • pp.71-78
    • /
    • 2009
  • Pipe section of bending part at the arch type pipe-house showed an ellipse with oblateness of 0.076 on the average. Flexural rigidity of bending part decreased by average 6.3% than that of an original round shape section. The deflection of arch type pipe-house measured by model experiments showed much bigger than the result of structural analysis. In case of arch type pipe-house, we supposed that the decrease of flexural rigidity for the bending part of pipes had an effect on deflection of roof under the working load. This effect should be considered in the structural analysis. Bending resistance of gable type pipe-house used a prefabricated connector which developed in this study showed about $1.5{\sim}1.8$ times stronger than that of the existing arch type or gable type processed bending. Therefore, we supposed that the gable-roofed prefabricated pipe-house is safer than arch type or bent gable type in case of heavy snowfall. According to house scales and section properties of steel pipe in use, safe snow depths and rafter intervals were presented for design of gable-roofed prefabricated pipe-house. Their standards were established in the range of the durable models recommended by RDA, and the comparative examinations were conducted by means of structural analysis. It was evaluated that the developed greenhouse model had a high applicability in the field.

Characteristics of Uplift Capacity of House Pipe Foundation according to Foundation Types and Soil Conditions (기초형식 및 지반조건에 따른 하우스파이프기초의 인발저항력 특성)

  • Song, ChangSeob;Jang, UngHee;Choi, DookHo;Kim, JungChul
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.117-126
    • /
    • 2020
  • The area of facility horticulture in Korea is increasing rapidly, the single-span pipe house which uses galvanized steel pipe as the main rafters occupies 78.7% of the facility area. Lightweight structures such as the single-span pipe house are vulnerable to meteorological disasters such as strong winds, economic losses of the state, local governments and farmers are continuing as construction does not meet the design standards. In order to minimize economic losses in the horticultural specialty facilities sector, the Rural Development Administration has been operating the horticultural disaster resilient standard for horticultural specialty facilities since April 2007. The only standard for the pipe connector is the disaster resilient standard, there is no standard for the uplift capacity of the house pipe foundation and the research on it is also insufficient. The purpose of this study is to investigate the characteristics of uplift capacity according to the foundation type, compaction ratio and embedded depth through soil box test. The results of the maximum uplift capacity according to the type, compaction ratio and embedded depth can be used as the basic data for the basic design of the pipe house conforming to the disaster resilient standard. Due to the limitation of soil box test, it may be different from the behavior of pipe house installed on site. In the future, the field test and the actual pipe house should be made and supplemented by comparing this result with the field test values.

The Comparative Analysis of Agricultural Pipe House by 2 and 3-Dimensional Modeling (농업용 파이프 하우스의 2차원 및 3차원 구조해석 비교분석)

  • Choi, Won;Yoon, Seong-Soo;Lee, Jeong-Jae
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.207-211
    • /
    • 2001
  • The scope has been small and the specification has been not suggested yet when the pipe house was planed by farmer in Korea. The construction has been made by the suitable agreement of builder and farmer. Also, life cycle time of the pipe house material under serviceability load is not suggested yet. This study is to consider problems of past 2-dimension modeling, to introduce new 3-dimension modeling about pipe house analysis and to know that how the structure under various loads conditions behaves. Therefore, the object is to discuss the current design and to suggest new analysis modeling of the pipe house.

  • PDF

Characteristics of Cooling Temperature of Cold Water Pipes Buried in the Wall of a Small Mobile Modular House (소형 이동식 모듈주택의 벽면에 냉수배관 매설에 의한 냉방온도 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.110-117
    • /
    • 2022
  • A chiller cooler absorbs the thermal energy of water to generate cold water and supplies the generated cold water to a cold water pipe buried in the wall of a small mobile modular house to greatly increase the cooling area. An attempt was made to reduce the required cooling time significantly. A small chiller cooler suitable for the cooling load of a small mobile modular house with an area less than 3.3 m2 was employed. When cooling is done during summer using a chiller cooler installed outdoors, heat absorption energy loss occurs in the cold water pipe owing to the high temperature. To address this, a study was conducted to reduce the endothermic energy loss significantly. As the mass flow rate of the cold water flowing inside the cold water pipe increased, the temperature decrease gradient of the cold water increased. From the start of the cooling operation, the air temperature of the small mobile modular house decreased linearly in proportion to the operation time. Furthermore, the temperature of the air inside the small mobile modular house decreased in proportion to the increase in the flow of water inside the cold water pipe.

Analyses of Actual State and Structural Safety of Regionally Characterized Greenhouses in Korea (지역별 특성화 온실의 실태 및 구조적 안전성)

  • 김문기;남상운;손정익;윤남규
    • Journal of Bio-Environment Control
    • /
    • v.3 no.2
    • /
    • pp.128-135
    • /
    • 1994
  • Recently, regionally characterized greenhouses have been built every place around the country. These greenhouses insist of their higher performance by considering regional merits than the greenhouses without considering regional ones, but it is not clear. The purpose of this study was to make clear the characteristics of the regionally characterized greenhouses through the analyses of actual state and structural safety. The greenhouses were investigated and classified into wide span house, large pipe house, arched lattice house, wooden house, viniculture house, and domed pipe house. The frames of wide span house, arched truss house, viniculture house and domed pipe house were analyzed to be structurally stable under the design wind speeds and snow depths in recurrence intervals of 15 or 30 years, but large pipe house was a little unstable and required some reinforcements, and wooden house turned out to be unstable. In addition, foundations of all characterized greenhouses were stable against pull - out capacity under the design wind speeds in recurrence interval of 30 years.

  • PDF

Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House (컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

A Study on the Strength Characteristics of Vinyl House Pipe Filled with Mortar (모르타르 충진 비닐하우스 파이프의 강도특성에 관한 연구)

  • Paik, Shinwon;Kim, Hanjoong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.13-17
    • /
    • 2015
  • There are many vinyl houses in rural areas. These vinyl houses have occasionally been collapsed due to heavy snow load in winter. If these vinyl houses are collapsed, many farmers get a lot of economical damages. So it is very important to built safe vinyl house that is able to withstand the applied heavy snow load. In this study, compressive buckling and flexural tests were performed to investigate the strength increase of circular mortar filled pipes. The results showed that buckling load and flexural moment of mortar filled pipes were increased 42 % ~ 82 %, 40 % ~ 44 % respectively more than only pipe without mortar. It is recommended that mortar filled pipes as main members of vinyl house have to be used to prevent collapsing due to the severe snow load.

저온기 육용계사의 적정 환기체계 구명

  • 이덕수;나재천;최희철;송준익;이상진;김형호
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2002.11a
    • /
    • pp.108-109
    • /
    • 2002
  • The study was carried out to iind out the suitable ventilation system of the broiler house in winter season in Korea. Ammonia (NH$_3$-N) gas concentration (4.2ppm) of the system of pipe air inlet-forced chimney outlet was lower than that of the system of side wall inlet. The growth performance of broilers in the house equiped with pipe air inlet-chimney exhaust was higher than that of other ventilation systmes in which the average daily gain, feed efficiency and heat cost per head in the system of pipe air inlet-forced chimney excretion were 45.6g, 1.71 and 35.4 won per head, respectively. When the lengths of pipe air inlets were compared, the wind speed from the 4 meter-inlet was highest. The temperature of the broiler house equipped with the pipe air inlet system was higher (5.9 ∼ 7.7$^{\circ}C$) than that of the curtains in side wall Inlet system, in which the pipe air inlet system expects the lower heat cost.

  • PDF

Experimental Study on the Ground Support Conditions of Pipe Ends in Single Span Pipe Greenhouse (단동파이프하우스의 지점조건 분석을 위한 실험 연구)

  • Lee, Suk-Gun;Lee, Jong-Won;Kwak, Cheul-Soon;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.17 no.3
    • /
    • pp.188-196
    • /
    • 2008
  • Single span pipe greenhouses (pipe houses) are widely used in Korea because these simple structures are suitable for construction by farmers thus reducing labor cost. However, these pipe houses are very weak and frequently damaged by heavy snow and strong wind. Pipe house is constructed by pipe fabricator, which is anchored to the ground by inserting each pipe end into ground to $30\sim40cm$, so the ground support condition of pipe end is not clear for theoretical analysis on greenhouse structure. This study was carried out to find out the suitable ground support condition needed f3r structural analysis when pipe house was designed. The snow and wind loading tests on the actual size pipe house were conducted to measure the collapsing shape, displacement and strain. The experimental results were compared with the structural analysis results for 4 different ground support conditions of pipe ends(fixed at ground surface, hinged at ground surface, fixed under ground and hinged under ground). The pipe house under snow load was collapsed at the eaves as predicted, and the actual strain at the windward eave and ground support under wind load was larger than that under snow load. The displacement was the largest at the hinged support under ground, followed by the hinged at ground surface, the fixed under ground and then the fixed at ground surface independent of displacement direction and experimental loading condition. The experimental results agreed most closely with the results of theoretical analysis at the fixed condition under ground among 4 different ground support conditions. As the results, it was recommended that the pipe end support condition of single span pipe greenhouse was the fixed under ground for structural analysis.

Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer (복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션)

  • Choi, Y.D.;Yoon, J.H.;Hong, J.K.;Lee, N.H.;Kang, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF