• Title/Summary/Keyword: pipe cleaning

Search Result 59, Processing Time 0.03 seconds

The Characteristics of Charging Water Spray at Electrostatic Precipitator

  • Chung, J.H.;Kanazawa, S.;Ohkubo, T.;Nomoto, Y.;Adachi, T.
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.132-136
    • /
    • 1994
  • The new spray system is proposed by using a pipe with hygroscopic needle electrode In order to develop an air-cleaning ESP with high collection efficiency for submicron particles and high removal efficiency for NOx, SO$_2$, NH$_3$. Fundamental characteristics of charging water spray, which is not an usual wet type, are investigated experimentally. As a result, corona discharging mode and ozone generation rate are significantly affected by the operational conditions, such as the applied voltage and wet condition of the needle electrode.

  • PDF

A study on the simulation method for the flushing flowrate and velocity in the watermain using a hydrant and a drain valve (소화전과 이토변을 이용한 플러싱 적용 시 관 내 세척유량과 유속 모의 방안에 관한 연구)

  • Gim, ARin;Lee, Eunhwan;Lee, SongI;Kim, kwang hyun;Jun, Hwandon
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1251-1260
    • /
    • 2022
  • Recently, due to the deterioration of watermains and the detachment of scale which is accumulated on the watermain surface, water quality accidents in a water supply network occur frequently. As scale accumulated on watermains is stabilized, it may not cause water quality accidents under the normal operating condition. However, due to water hammer or transient flow caused by the abrupt velocity and/or direction of flow change, it can be detached from the watermain surface resulting in water quality accidents. To prevent these kinds of water quality accidents, it is required to remove scale by watermain cleaning regularly. Many researches about flushing which is the most popular water cleaning method are focused on the desirable velocity criteria and the cleaning condition to accomplish the effect of flushing whereas less amount of research effort is given to develop a method to consider whether the desirable velocity for flushing can be obtained before flushing is performed. During flushing, the major and minor headloss is occurred when flushing water flows through a hydrant or drain valve. These headloss may slow down the velocity of flushing water so that it can reduce the flushing effect. Thus, in this study, we suggest a method to simulate the flow velocity of flushing water using "MinorLoss Coefficient" and "Emitter Coefficient" in EPANET. The suggested method is applied to a sample network and the water supply network of "A" city in Korea to compare the flushing effect between "flushing through a hydrant" and "flushing through a drain valve". In case of "flushing through a hydrant", if the hydraulic condition ocurring from a watermain pipe connecting to the inlet pipe of a hydrant to the outlet of a hydrant is not considered, the actual flowrate and velocity of a flow is less than the simulated flowrate and velocity of a flow. In case of "flushing through a drain valve", the flushing velocity and flowrate can be easily simulated and the difference between the simulated and the actual velocity and flowrate is not significant. Also, "flushing through a drain valve" is very effective to flushing a long-length pipe section because of its efficiency to obtain the flushing velocity. However, the number and location of a drain valve is limited compared to a hydrant so that "flushing through a drain valve" has a limited application in the field. For this reason, the engineer should consider various field conditions to come up with a proper flushing plan.

The Anti-scale Effect according to Array of Magnetic Device (자화장치의 배열별 스케일 생성 억제 효과)

  • Nam, Joongwoo;Han, Yunsu;Lee, Jonghwi;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.2
    • /
    • pp.13-17
    • /
    • 2013
  • Clogging phenomenon in drainage system is one of the important problems and this phenomenon would be bad effect to structure of tunnel, so it needs a remedy urgently. Recently, scale in drainage pipe is removed by water jet cleaning and other treatment. But these treatments need much cost and regular management. In this study, magnetic device was used to solve this problem and an effect of prohibiting scale in accordance with array of magnetic device was investigated. Analysis method was visual analysis and measuring weight of each pipes. As a result, interior top and out-bottom (CASE II) was the most effective array to prohibit scale. and interior left and right (CASE III), interior top and bottom (CASE I) was effective for prohibiting scale in order.

Solid-liquid 2phase flow in a concentric annulus with rotation of the inner cylinder (안쪽축이 회전하는 동심환형관내 고-액 2상 유동연구)

  • Kim, Young-Ju;Han, Sang-Mok;Woo, Nam-Sub;Hwang, Young-Kyu
    • Journal of Energy Engineering
    • /
    • v.18 no.2
    • /
    • pp.87-92
    • /
    • 2009
  • An experimental investigation is conducted to study a 2-phase vertically upward hydraulic transport of solid particles by water and non-Newtonian fluids in a slim hole concentric annulus with rotation of the inner cylinder. Rheology of particulate suspensions in viscoelastic fluids is of importance in many applications such as particle removal from surfaces, transport of proppants in fractured reservoir and cleaning of drilling holes, etc. In this study, a clear acrylic pipe was used in order to observe the movement of solid particles. Annular velocities varied from 0.3 m/s to 2.0 m/s. The mud systems included fresh water and CMC solutions. Main parameters considered in the study were inner-pipe rotation speed, fluid flow regime and particle injection rate. A particle rising velocity and pressure drop in annulus have been measured for fully developed flows of water and of aqueous solutions. For both water and 0.2% CMC solutions, the higher the concentration of the solid particles is, the larger the pressure gradients become.

Study on Solid-liquid Mixture Flow in Inclined Annulus (경사 환형관내 고-액 혼합 유동특성에 관한 연구)

  • Kim, Young-Ju;Kim, Young-Hun;Woo, Nam-Sub
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.15-20
    • /
    • 2011
  • This study carried out a series of experiments involving impact tests (Drop Weight type & Charpy type with a standard specimen and newly designed I-type specimen), hardness tests, and fracture surface observations of French-made roll shell steel (F), abnormal roll shell steel (M), reheated roll shell steel (R), and S25C steel under heat treatment conditiAn experimental study was carried out to study the solid-liquid mixture upward hydraulic transport of solid particles in vertical and inclined annuli with a rotating inner cylinder. The lift forces acting on a fluidized particle play a central role in many important applications such as the removal of drill cuttings in horizontal drill holes, sand transport in fractured reservoirs, sediment transport, the cleaning of particles from surfaces, etc. In this study a clear acrylic pipe was used to observe the movement of solid particles. Annular velocities varied from 0.4 to 1.2 m/s. The effect of the annulus inclination and drill pipe rotation on the carrying capacity of a drilling fluid, particle rising velocity, and pressure drop in a slim hole annulus were measured for fully-developed flows of water and aqueous solutions of CMC (sodium carboxymethyl cellulose) and bentonite. The rotation of the inner cylinder was efficient at carrying particles to some degree. For a higher particle volume concentration, the hydraulic pressure loss of the mixture flow increased because of the friction between the wall and solids or between solids.

The assessment of self cleaning velocity and optimal flushing velocity in water distribution system (상수관망의 자가세척 유속과 적정 플러싱 유속 평가)

  • Bae, Cheol-Ho;Choi, Doo Yong;Kim, Ju-Hwan;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.

A Development of Offshore plant Piping Process Monitoring System Based on 3D CAD Model (3D CAD 모델 기반 해양플랜트 배관 공정 모니터링 시스템 개발)

  • Kim, Hyun-Cheol;Lee, Gyu-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.58-65
    • /
    • 2020
  • 3D Models of offshore plant piping materials designed by 3D CAD systems are provided to the production processes in the form of 2D piping drawings and 2D piping installation drawings. In addition to the standard engineering information, the purchasing, procurement, manufacturing, installation, and inspection of raw materials are managed systematically in an integrated process control system. The existing integrated process management system can help reduce the processing time by managing the flow and progress of resources systematically, but it does not include 3D design model information. Hence, it is difficult to understand complicated pipe structures before installing the pipe. In addition, when design changes or immediate design modifications are required, it is difficult to find related data or exchange information quickly with each other. To solve this problem, an offshore plant-piping process-monitoring system was developed based on a 3D model. The 3D model-based piping monitoring system is based on Visual Studio 2017 C# and UNITY3D so that the piping-process work information can be linked to the 3D CAD model in real time. In addition, the 3D model could check the progress of the pipe installation process, such as block, size, and material, and the progress of functional inspection items, such as cleaning, hydraulic inspection, and pneumatic inspection.

Semiconductor wafer exhaust moisture displacement unit (반도체 웨이퍼 공정 배기가스 수분제어장치)

  • Chan, Danny;Kim, Jonghae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5541-5549
    • /
    • 2015
  • This paper introduces a safer and more power efficient heater by using induction heating, to apply to the semiconductor wafer fabrication exhaust gas cleaning system. The exhaust gas cleaning system is currently made with filament heater that generates an endothermic reaction of N2 gas for the removal of moisture. Induction theory, through the bases of theoretical optimization and electronic implementation, is applied in the design of the induction heater specifically for the semiconductor wafer exhaust system. The new induction heating design provides a solution to the issues with the current energy inefficient, unreliable, and unsafe design. A robust and calibrated design of the induction heater is used to optimize the energy consumption. Optimization is based on the calibrated ZVS induction circuit design specified by the resonant frequency of the exhaust pipe. The fail-safe energy limiter embedded in the system uses a voltage regulator through the feedback of the MOSFET control, which allows the system performance to operate within the specification of the N2 Heater unit. A specification and performance comparison from current conventional filament heater is made with the calibrated induction heater design for numerical analysis and the proof of a better design.

Analysis of Research for the Actual State and Management of Automated Horticultural Facilities (경북지역 현대화 원예시설의 관리실태 조사분석)

  • 정현교;이기명;박규식
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.174-186
    • /
    • 1996
  • This study was carried out in order to understand the plan, design, constructing and actual condition of management of modernized horticultural facilities in Kyungpook Province which had been constructed from 1992 to 1995 funded by Government support. The aim of this study is to provide reference data for success of the forth project. It was performed by making up a question about driving of project and management condition of equipment after constructing. The results obtained from this study are as follows: 1. 73.5% of facilities horticulture farmhouse recognized that the prospect of greenhouse is bright, but 92.5% of the farmhouse also recognised that they need technical consultation on protected horticulture farming. Therefore, technical educations would must be enhanced about foundation of greenhouse and cultivation technique. 2. The holding times of explanatory meetings, cause of understanding to farmhouse, were one or two times in greenhouse construction, and 62.5% of the farmhouse expressed the insufficiency at the explanation and educational data. For this reason, it was judged that the construction contract had been delayed more than 5 months in 49.3% of the farmhouse after the decision of project budget. 3. In constructing after a contract, the rates of construction delay is 53.4% and defect occurrence is 41.1%. The biggest reasons of construction delay was insufficiency of worker and materials supply. Each percentage is 29.1%. And the reason of defect occurrence is badness of machinery equipment(62.9% ). 4. In management of greenhouse, a pipe-constructed plastic film greenhouse changes plastic film every one and three years because of sticking dust on plastic film. It was needed to about in cleaning technique of coverings. Because that used 3-5 years only half of the expected life span. 5. The order of broken rating in the subsidiary equipment is like this lollop ventilator (42.8%), a general control system(33.3%) especially, in the case of a general control system, the rate of all family can control is 52.7%. so, it is time to develop easy control equipment which every one could use as soon as possible. 6. When choose heat generator as decide capacity, the most priority is the mount of heat generator the percent is 45.5% heat generator and as decide model, the private purchase's percent is 77.3%. It is higher than a public bidding heat generator the percent is 22.7% heat generator when it compare with a public bidding. In the case of $CO_2$ generator, using rate is only 19.0%. The using rate is very low, so it needs education how to use depends on the way of the subsidiary equipment. 7. In the case of seedlings, it is asked to use factory-processed seedling effectively. because it's difficult to get security of labors(58.8%), hoped crops (55.9%) access same crops(29.4%) much more and changing of crops depends on market situation. that is the main reason the lack of knowhow.

  • PDF

Estimation of Solid Sediments Load by Sewer and Land Surface for Maintenance of Combined Sewer Systems (합류식 관거 유지관리를 위한 하수 및 지표면 고형물 부하량 산정)

  • Lee Jae-Soo;Park Moo-Jong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.533-544
    • /
    • 2006
  • The deposition of solids in combined sewer systems results in a loss of flow capacity that may restrict flow and cause a local flooding and enhanced solids deposition. In order to solve these problems and proper pipe management, estimation of solid loads from sewer and surface in a drainage basin is needed but this task is very difficult and extremely expensive. In this study, generalized procedures for estimating sewer solid loads during dry weather in combined sewer systems and for estimating solid loads on surface in a drainage basin developed by the U. S. Environmental Protection Agency were applied and analyzed in Gunja drainage basin in Korea. As result, the estimated solid loads from sewer and surface are 205.8,759kg/yr and 1,321,993kg/yr respectively, and total solid loads is 1,527,752kg/yr. The estimated solid removal from street cleaning, dredging from pipe system and pumping house is 1,486,636kg/yr. Therefore, the applied methods show resonable results. More reliable estimation can be achieved if long-term measurements and adjustment of estimation equations are carried out, and this estimation methods can be used usefully for the management of combined sewer system with reduction of cost and effort.