• 제목/요약/키워드: piezoelectric actuator ultrasonic

검색결과 61건 처리시간 0.026초

압전구동기를 이용한 정밀 가공용 초음파 진동장치 해석 및 실험 (Analysis and Experiment of Ultrasonic Vibration Mechanism using PZT Actuator for Precision Laser Machining)

  • 김우진;전용호;조성학
    • 한국정밀공학회지
    • /
    • 제28권12호
    • /
    • pp.1347-1352
    • /
    • 2011
  • Recently, as the aged population grows around the world, many medical instruments, devices, and their fabrication processes are developing. Among the devices, a drug delivery stent is a good example for precision machining. Conventional drug delivery stent has problem of the remaining polymer because the drug is coated on the surface with it. If the drug is impregnated into the micro hole array on the stent surface, the polymer can be perfectly eliminated. Micro sized holes are generally fabricated by laser machining however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver the stend to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for abrication of micro sized holes better. The results indicated that the burr size can be significantly decreased with vibration assisted in nanosecond pulse laser drilling test.

Design of a Valveless Type Piezoelectric Pump for Micro-Fluid Devices

  • Kim, Hyun-Hoo;Oh, Jin-Heon;Yoon, Jae-Hun;Jeong, Eui-Hwan;Lim, Kee-Joe
    • Transactions on Electrical and Electronic Materials
    • /
    • 제11권2호
    • /
    • pp.65-68
    • /
    • 2010
  • The operation principle of a traveling wave rotary type ultrasonic motor can be successfully applied to the fluidic transfer mechanism of the micro-pump. This paper proposes an innovative valveless micro-pump type that uses an extensional vibration mode of a traveling wave as a volume transportation means. The proposed pump consists of coaxial cylindrical shells that join the piezoelectric ceramic ring and metal body, respectively. In order to confirm the actuation mechanism of the proposed pump model, a numerical simulation analysis was implemented. In accordance with the variations in the exciting wave mode and pump body dimension, we analyzed the vibration displacement characteristics of the proposed model, determined the optimal design condition, fabricated the prototype pump from the analysis results and evaluated its performance. The maximum flow rate was approximately $595\;{\mu}L/min$ and the highest back pressure was 0.88 kPa at an input voltage of $130\;V_{rms}$. We confirmed that the peristaltic motion of the piezoelectric actuator was effectively applied to the fluid transfer mechanism of the valveless type micro pump throughout this research.

와이어 본딩용 트랜스듀서 혼의 진동 특성 (Vibration Characteristics of a Wire-Bonding Transducer Horn)

  • 임빛;한대웅;이승엽;안근식;강경완;김국환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.583-588
    • /
    • 2007
  • This paper investigates the vibration characteristics of a wire-bonding transducer horn for high speed welding devices. The sample wire-bonder uses the input frequency of 136 kHz. The ultrasonic excitation causes the various vibrations of transducer horn and capillary. The vibration modes and frequencies close to the exciting frequency are identified using ANSYS. The nodal lines and amplification ratio of the ultrasonic horn are also obtained in order to evaluate the bonding performance of the sample wire-bonder system. The FEM results and experimental results show that the sample wire-bonder system uses the bending mode of 136 kHz as principal motion for bonding. The major longitudinal mode exists at 119 kHz below the excitation frequency. It is recommeded that the sample system is to set the excitation frequency at 119 kHz to improve bonding performance.

  • PDF

나노표면개질 용 초음파 진동자 설계 및 제작 (Design and Manufacturing of an Ultrasonic Waveguide for Nano-surface Treatment)

  • 김현세;이양래;임의수
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1115-1119
    • /
    • 2014
  • In this article, a 20 kHz ultrasonic waveguide for nano-surface treatment was designed and manufactured. When designing the system, finite element analysis with ANSYS software was performed to find optimal dimensions of the waveguide, which can raise energy efficiency. Consequently an anti-resonance frequency of an Al waveguide with a piezoelectric actuator was 20 kHz, which predicted the experimentally obtained value of 18 kHz well. For the assessment of the performance, Steel Use Stainless (SUS) 304 and chromium molybdenum steel (SCM) 435 specimens were tested. Cross-sectional microscopies of SUS304 were taken and they showed that the treated thickness was $30{\mu}m$. Additionally, hardness tests of SCM435 were done and the hardness before the process was 14.0 Rockwell Hardness-C scale (HRC) and after the process was 20.5 HRC, respectively, which means 46% increase. Considering these results, the developed ultrasonic system is thought to be effective in the nano-surface treatment process.

초음파 모터용 람다형 다방향 변환자 (Multi-directionally Movable Lambda Shape Transducer for Ultrasonic Motor)

  • 도영수;남효덕;김영덕
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 2008
  • The transducer for multi-directionally movable ultrasonic motor having lambda shaped vibrators has been proposed and designed. The two branches cross at a right angle with each other at the tip. FEM analyses of lambda shaped transducer were carried out to find vibration modes for ultrasonic motor. The lambda shaped transducer has one symmetric mode and two anti-symmetric modes. The symmetric mode generates the normal direction motion of the tip. The lateral and vertical direction motion of the tip are excited by two anti-symmetric modes. The normal and lateral direction motions made an lateral elliptic trajectory. And the normal and vertical direction motions made an vertical elliptic trajectory normal to previous one. The transducer with 1 mm in thickness and 25 mm in length has been fabricated and evaluated. The resonance frequencies of the transducer was 32 kHz and 103 kHz. The tangential and vertical vibration displacement of the transducer having the lateral elliptic trajectory were $1.5{\mu}m\;and\;1.1{\mu}m$, respectively at the driving voltage of 100 Vpp and frequency of 32 kHz and 103 kHz. And the tangential and vertical vibration displacement of the transducer having the vertical elliptic trajectory were $0.4{\mu}m\;and\;0.2{\mu}m$, respectively at the same driving condition.

액츄에이터 응용을 위한 $Fe_2O_3$$MnO_2$ 첨가에 따른 $Pb(Ni_{1/3}Nb_{2/3})O_3-PbTiO_3-PbZrO_3$ 세라믹스에서의 유전 및 압전 특성 (Effects of $Fe_2O_3$ and $MnO_2$ Additives on Dielectric and Piezoelectric Properties of $Pb(Ni_{1/3}Nb_{2/3})O_3-PbTiO_3-PbZrO_3$ Ceramics for Actuator Applications)

  • 임은경;백종후;김창일;신범승;임종인;이영진;최병현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.329-330
    • /
    • 2006
  • 본연구에서는 초음파 모터 등의 고출력 액츄에이터에 응용 가능한 $0.4Pb(Ni_{1/3}Nb_{2/3})O_3$-$0.6Pb(Zr_{0.405}Ti_{0.595})O_3$ + 0.25wt% $Fe_2O_3$ 조성시스템에 $MnO_2$ (0~1 wt.%)첨가하여 압전, 유전특성 및 미세구조에 관해 고찰하였다. 본조성을 $1125{\sim}1175^{\circ}C$ 온도에서 2시간 소결하여 시편을 제조하였으며 이의 결정구조 및 미세조직을 분석하였다. $MnO_2$ 첨가량 증가에 따라 압전 상수와 전기기계결함계수는 감소하였으며, 기계적 품질계수는 0.5 wt% 첨가시까지 증가하였으나 첨가량이 그 이상 증가함에 따라 감소하였다. 압전특성은 $1125^{\circ}C$에서 소결한 $MnO_2$ 0.5wt%조성에서 ${\varepsilon}r$ = 2040, kp = 0.66, $d_{33}$ = 504, Qm=438의 우수한 특성을 나타내었다.

  • PDF

압전구동기를 이용한 정밀 가공용 초음파 진동장치 설계 (Design of Ultrasonic Vibration Device using PZT Actuator for Precision Laser Machining)

  • 김우진;;조성학;박종권;이문구
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.8-12
    • /
    • 2011
  • As the aged population grows around the world, many medical instruments and devices have been developed recently. Among the devices, a drug delivery stent is a medical device which requires precision machining. Conventional drug delivery stent has problems of residual polymer and decoating because the drug is coated on the surface of stent with the polymer. If the drug is impregnated in micro hole array on the surface of the stent, the problem can be solved. Micro sized holes are generally fabricated by laser machining; however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver it to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for the fabrication of micro sized holes. If the mechanism vibrates the eyepiece of the laser machining head, the laser spot on the workpiece will vibrate vertically because objective lens in the eyepiece shakes by the mechanism's vibration. According to the former researches, the vibrating frequency over 20kHz and amplitude over 500nm are preferable. The vibration mechanism has cylindrical guide, hollowed PZT and supports. In the cylinder, the eyepiece is mounted. The cylindrical guide has upper and low plates and side wall. The shape of plates and side wall are designed to have high resonating frequency and large amplitude of motion. The PZT also is selected to have high actuating force and high speed of motion. The support has symmetrical and rigid characteristics.

  • PDF

압전 액츄에이터를 이용한 단순지지 평판에서의 초음파 대역 진동 발생 (Excitation of ultrasonic vibration on a simply supported plate with a piezoelectric actuator)

  • 안순홍;노용래
    • 한국음향학회지
    • /
    • 제17권2호
    • /
    • pp.25-31
    • /
    • 1998
  • 본 연구에서는 자동차 유리판에 초음파 대역 진동을 효율적으로 발생시킬 수 있는 압전 액츄에이터를 개발하고자 하였다. 자동차 유리판을 단순지지 평판으로 가정하였으며, 액츄에이터로는 PZT 진동자를 사용하였다. 유한 요소법(Finite Element Method)을 통하여 유리판의 최적 공진 주파수와 유리판에 부착할 압전 진동자의 구조 조건인 최적 위치와 개 수를 결정하였다. 설계 결과에 따라 자동차 유리판에 압전 진동자를 부착하여 임펄스 응답 해석(impulse response analysis)과 임피던스 해석(impedance analysis)을 수행하여 구동 주 파수를 확인하였다. 그 결과, 이 주파수로 가진하여 유리판 전면에 걸쳐 고른 초음파 진동이 분포함을 확인하였으며, 나아가 전기적 임피던스 매칭(impedance matching)을 통해 더 큰 효율의 진동을 발생시킬 수 있었다.

  • PDF

냉각용 초음파 웨이브가이드의 진동 특성 (Vibration characteristics of an ultrasonic waveguide for cooling)

  • 김현세;임의수
    • 한국음향학회지
    • /
    • 제39권6호
    • /
    • pp.568-575
    • /
    • 2020
  • 초음파는 다양한 산업 분야에서 널리 사용이 되고 있다. 그 중에 도전적인 분야로 전자부품의 냉각이 있다. 초음파 냉각 기술은 작동 유체로, 기존의 지구온난화를 유발하는 프레온 가스 대신에 Ar(아르곤), N2(질소) 등의 기체로 대체가 가능하다. 또한 움직이는 부품이 없어 높은 내구성을 가질 수 있다. 그러므로 이러한 환경 문제와 내구성 관점에서 초음파 냉각 장치의 개발이 필요하다. 본 논문에서는 설계와 제작 공정에 대하여 설명하고 있다. 이 시스템을 설계할 때, 냉각기 시제품을 이용하여 유효성 테스트를 수행하였다. 이 결과를 바탕으로, ANSYS 프로그램을 사용한 유한요소해석을 수행하였다. 반공진 주파수는 34.8 kHz로 예측이 되었으며, 이는 실험치인 34.6 kHz과 0.6 %의 오차로 잘 일치하였다. 또한 초음파 웨이브가이드의 반공진 주파수는 39.4 kHz로 예측이 되었고, 역시 실험치인 39.8 kHz과 1.0 %의 오차로 잘 일치함을 알 수 있었다. 이러한 결과를 바탕으로 볼 때, 개발된 초음파 웨이브가이드는 마이크로칩의 냉각에 활용 될 수 있을 것으로 보인다.

압축하중 및 전계 인가에 따른 PIN-PMN-PT 단결정의 33-모드 유전 및 압전특성 (The 33-mode Dielectric and Piezoelectric Properties of PIN-PMN-PT Single Crystal under Stress and Electric Field)

  • 임재광;박재환;이정호;이상구
    • 마이크로전자및패키징학회지
    • /
    • 제27권4호
    • /
    • pp.91-96
    • /
    • 2020
  • Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3계 압전 단결정의 유전특성과 압전특성을 전계 및 압축응력 인가 조건 하에서 33-모드 방식으로 측정하였다. 110~140℃ 영역에서 저온 rhombohedral 구조에서 고온 tetragonal 구조로의 상전이가 관찰되었으며, cubic 구조로 변화하는 큐리온도는 165℃ 정도로 나타났다. 압축응력 및 전계 변화에 따른 분극의 크기변화를 측정하였다. 전계인가 분극 곡선의 기울기로부터 비유전율을 계산하였고, 인가되는 응력의 크기가 증가할수록 계산된 비유전율의 크기는 증가하고, 인가되는 전계의 크기가 증가할수록 비유전율의 크기는 감소하는 경향성을 나타내었다. 압축응력 및 전계 변화에 따른 변위 거동을 측정하였으며, 곡선의 기울기로부터 압전상수를 계산하였고 압력인가에 따른 상전이를 확인하였다. 수중 또는 의료용 초음파 발진자로 실제 응용할 경우 선형성을 유지하여 구동이 가능하기 위하여 소자 기구물을 형성하는 단계에서 인가하게 되는 압축응력의 크기와 구동 전계의 DC 바이어스의 크기를 적절하게 설계할 필요가 있다.