• Title/Summary/Keyword: physical camera parameters

Search Result 49, Processing Time 0.024 seconds

Development of Stretchable Joint Motion Sensor for Rehabilitation based on Silver Nanoparticle Direct Printing (은 나노입자 프린팅 기반의 재활치료용 신축성 관절센서 개발)

  • Chae, Woen-Sik;Jung, Jae-Hu
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.183-188
    • /
    • 2021
  • Objective: The purpose of this study was to develop a stretchable joint motion sensor that is based on silver nano-particle. Through this sensor, it can be utilized as an equipment for rehabilitation and analyze joint movement. Method: In this study, precursor solution was created, after that, nozel printer (Musashi, Image master 350PC) was used to print on a circuit board. Sourcemeter (Keithley, Keithley-2450) was used in order to evaluate changes of electric resistance as the sensor stretches. In addition, the sensor was attached on center of a knee joint to 2 male adults, and performed knee flexion-extension in order to evaluate accurate analysis; 3 infrared cameras (100 Hz, Motion Master 100, Visol Inc., Korea) were also used to analyze three dimensional movement. Descriptive statistics were suggested for comparing each accuracy of measurement variables of joint motions with the sensor and 3D motions. Results: The change of electric resistance of the sensor indicated multiple of 30 times from initial value in 50% of elongation and the value of electric resistance were distinctively classified by following 10%, 20%, 30%, 40% of elongation respectively. Through using the sensor and 3D camera to analyze movement variable, it showed a resistance of 99% in a knee joint extension, whereas, it indicated about 80% in flexion phase. Conclusion: In this research, the stretchable joint motion sensor was created based on silver nanoparticle that has high conductivity. If the sensor stretches, the distance between nanoparticles recede which lead gradual disconnection of an electric circuit and to have increment of electric resistance. Through evaluating angle of knee joints with observation of sensor's electric resistance, it showed similar a result and propensity from 3D motion analysis. However, unstable electric resistance of the stretchable sensor was observed when it stretches to maximum length, or went through numerous joint movements. Therefore, the sensor need complement that requires stability when it comes to measuring motions in any condition.

The Effect of Arm Swing on Gait in Healthy Adults (팔 흔들기가 정상인의 보행에 미치는 영향)

  • Jung, Hwa-Su;Choi, Su-Hee;Park, Sun-Ja;Oh, Hye-Jin;Cho, Hwa-Young
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.451-459
    • /
    • 2014
  • This study was to performed to get the reference data of the kinetic parameters for normal subjects according to the arm swing type. Forty-five normal subjects($22.62{\pm}2.69years$) pariticpated in this study and preformed 4 sequence according to the arm swing type as follows; first procedure-normal arm swing, second procedure-one arm swing, thrid procedure-no arm swing, fourth procedure-fitness arm swing. There were significant differences according to the arm swing type in the kinetic parameters such as walking speed, hip power, ground reaction force of vertical in terminal stance phase(p<.05). These finding can be utilized (a) as a reference for kinetic data of gait analysis in normal subjects, and (b) as an aide in evaluating and treating patients who have problems relating to gait.

Effects of Rehabilitation Duration on Lower Limb Joints Biomechanics dur ing Drop Landing in Athletes with Functional Ankle Instability (기능적 발목 불안정성 선수들의 드롭랜딩 시 재활 기간이 하지 관절의 운동역학적 특성에 미치는 영향)

  • Cho, Joon-Haeng;Kim, Kyoung-Hun;Lee, Hae-Dong;Lee, Sung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.395-406
    • /
    • 2010
  • The purpose of this study was to analyze the changes in kinematic and kinetic parameters of lower extremity joint according to rehabilitation period. Fourteen collegiate male athletes(age: $22.1{\pm}1.35$ years, height: $182.46{\pm}9.45cm$, weight: $88.63{\pm}9.25kg$) and fourteen collegiate athletes on functional ankle instability(age: $21.5{\pm}1.35$ years, height: $184.45{\pm}9.42cm$, weight: $92.85{\pm}10.85kg$) with the right leg as dominant were chosen. The subjects performed drop landing. The date were collected by using VICON with 8 camera to analyze kinematic variables and force platform to analyze kinetic variables. There are two approaches of this study, one is to compare between groups, the other is to find changes of lower extremity joint after rehabilitation. In comparison to the control group, FAI group showed more increased PF & Inversion at IC and decreased full ROM when drop landing. Regarding the peak force and loading rate, it resulted in higher PVGRF and loading. FAI group used more increased knee and hip ROM because of decreased ankle ROM to absorb the shock. And it used sagittal movement to stabilize. In terms of rehabilitation period, FAI group showed that landing patterns were changed and it increased total ankle excursion and used all lower extremity joint close to normal ankle. Regarding the peak force and loading rate, FAI group decreased PVGRF and loading rate. and also showed shock absorption using increased ankle movement. And COP variable showed that proprioception training increased stability during 8 weeks. The results of this study suggest that 8 weeks rehabilitation period is worthwhile to be considered as a way to improve neuromuscular control and to prevent sports injuries.

Augmented Reality Based Tangible Interface For Digital Lighting of CAID System (CAID 시스템의 디지털 라이팅을 위한 증강 현실 기반의 실체적 인터페이스에 관한 연구)

  • Hwang, Jung-Ah;Nam, Tek-Jin
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.119-128
    • /
    • 2007
  • With the development of digital technologies, CAID became an essential part in the industrial design process. Creating photo-realistic images from a virtual scene with 3D models is one of the specialized task for CAID users. This task requires a complex interface of setting the positions and the parameters of camera and lights for optimal rendering results. However, the user interface of existing CAID tools are not simple for designers because the task is mostly accomplished in a parameter setting dialogue window. This research address this interface issues, in particular the issues related to lighting, by developing and evaluating TLS(Tangible Lighting Studio) that uses Augmented Reality and Tangible User Interface. The interface of positioning objects and setting parameters become tangible and distributed in the workspace to support more intuitive rendering task. TLS consists of markers, and physical controller, and a see-through HMD(Head Mounted Display). The user can directly control the lighting parameters in the AR workspace. In the evaluation experiment, TLS provide higher effectiveness, efficiency and user satisfaction compared to existing GUI(Graphic User Interface) method. It is expected that the application of TLS can be expanded to photography education and architecture simulation.

  • PDF

PHOTOMETRIC OBSERVATIONS OF THE CONTACT BINARY SYSTEM CC COM (접촉쌍성 CC Com의 측광학적 관측과 분석)

  • Jeong, Jang-Hae;Kim, Chun-Hwey;Kim, Yong-Gi
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.2
    • /
    • pp.99-110
    • /
    • 2007
  • A total of 824 observations (206 in ${\Delta}B$, 206 in ${\Delta}V$, 206 in ${\Delta}R$, 206 in ${\Delta}I$ for CC Com were made on 3 nights from March 3 to April 3 in 2002 using the 61cm telescope with 2K CCD camera of the Sobaeksan Optical Astronomy Observatory of KASI. From our observations 9 times of minimum light were newly determined. Combined analysis of our new BVRI light curves with the double-lined radial velocity curves of Pribulla et al. (2007) were made with the 2004 Wilson-Devinney(WD) binary model code to yield new physical parameters of the CC Com system. Small asymmetries in light curves were explained with the adoption of two hot spots on the cool secondary.

PHOTOMETRIC OBSERVATIONS OF THE CONTACT BINARY SYSTEM V523 CASSIOPEIAE (접촉쌍성 V523 Cas의 측광학적 관측과 분석)

  • Jeong Jang-Hae;Kim Chun-Hwey;Lee Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.177-188
    • /
    • 2006
  • A total of 920 observations (230 in ${\Delta}B$, 230 in ${\Delta}V$, 230 in ${\Delta}R$, 230 in ${\Delta}I$) for V523 Cas were made on 5 nights from January 6 to 24 in 2003 using the 61cm telescope with 2K CCD camera of the Sobaeksan Optical Astronomy Observatory of KASI. From our observations 9 times of minimum light were newly determined. Combined analysis of our new BVRI light curves with the double-lined radial velocity curves of the Rucinski et al.'s (2003) were made with the 2004 Wilson-Devinney (WD) binary model to yield new physical parameters of the V523 system. Small asymmetries in light curves were explained with the adoption of a cool spot on the hot primary and a hot spot on the cool secondary.

Changes of the Flame Temperature and OH Radical in the Unsteady Extinction Process (비정상 소화 과정에서의 화염 온도 및 OH 라디칼의 변화)

  • Lee, Uen-Do;Lee, Ki-Ho;Oh, Kwang-Chul;Shin, Hyun-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.12
    • /
    • pp.1557-1566
    • /
    • 2004
  • A flame extinction phenomenon is a typical unsteady process in combustion. Flame extinction is characterized by various physical phenomena, such as convection, diffusion, and the production of heat and mass. Flame extinction can be achieved by either increasing the strain rate or curvature, by diluting an inert gas or inhibitor, or by increasing the thermal or radiant energy loss. Though the extinction is an inherently transient process, steady and quasi-steady approaches have been used as useful tools for understanding the flame extinction phenomenon. Recently, unsteady characteristics of flames have been studied by many researchers, and various attempts have been made to understand unsteady flame behavior, by using various extinction processes. Representative parameters for describing flame, such as flame temperature, important species related to reactions, and chemi-luminescence of the flame have been used as criterions of flame extinction. In these works, verification of each parameter and establishing the proper criterions of the extinction has been very important. In this study, a time-dependent flame temperature and an OH radical concentration were measured using optical methods, and the instantaneous change of the flame luminosity was also measured using a high-speed ICCD (HICCD) camera. We compare the unsteady extinction points obtained by three different methods, and we discuss transient characteristics of maximum flame temperature and OH radical distribution near the extinction limit.

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • Environmental Mutagens and Carcinogens
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.