• Title/Summary/Keyword: photovoltaic characteristics

Search Result 732, Processing Time 0.029 seconds

Simulator implementation for characteristics analysis of PV System (태양광발전시스템 특성해석을 위한 시뮬레이션 구현)

  • Park, J.M.;Jeong, B.H.;Piao, Z.G.;Choi, Y.O.;Cho, G.B.;Baek, H.L.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.383-385
    • /
    • 2006
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW large scale applications installed in Chosun University dormitory roof and simulation tool. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory. In this paper represent 50kW utility PV system examination result.

  • PDF

A Study on Photovoltaic/Wind/Diesel Hybrid Power System

  • Cho Jun-Seok;Gho Jae-Seok;Kim Kyung-Hyun;Choe Gyu-Ha;Kim Eung-Sang;Lee Chang-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.698-702
    • /
    • 2001
  • In this paper, to solve the defect of stand-alone type power system in a remote area, a hybrid power system with photovoltaic/wind/diesel generators is proposed. A hybrid power system has a power-balanced controller to equilibrate generation power with a given load demand and which is composed of common DC power system. To execute a power-balanced control, a hybrid power system is assumed that all of power generators have the characteristics of an equivalent current-source and load sharing control technique must be needed at the same time. So this paper describes the algorithm of interactive technique for design of a hybrid power system.

  • PDF

Batteries for Photovoltaic Applications (태양전지용 축전지)

  • Kim, D.S.;Ebong, A.U.;Lee, S.H.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.43-53
    • /
    • 1997
  • Characteristics and properties of batteries applicable to the photovoltaic system are described in this paper. The use of a number of different types of batteries and designs depends on the many and varied requirements for battery power and the different environmental and electrical conditions under which they must operate. Most of the batteries used in PV systems are lead/acid batteries, though nickel/cadmium batteries are used for small applications in locations with extreme climates or where high reliability is essential such as spacecraft. The vanadium redox battery has been acknowledged as a promising energy storage system for a wide range of applications.

  • PDF

Modeling of Grid-Connected Photovoltaic Generation using Matlab/Simulink (Matlab/Simulink를 이용한 계통연계형 태양광발전 모델링)

  • Seo, H.C.;Yoon, Y.M.;Kim, S.R.;Lee, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.92-94
    • /
    • 2008
  • This paper introduces the modeling of grid-connected photovoltaic(PV) generation using Matiab/Simulink. The model is based on the equivalent circuit of the PV solar cell including the effects of solar irradiation and temperature changes. The PV arrays are modeled to be built up with the series/parallel combination of PV solar cell and are connected to the distribution system via an inverter. The simulation results show that the typical characteristics and outputs of the PV arrays are accurate.

  • PDF

Analysis on the Characteristics of Photovoltaic/Wing Hybrid PCS System (태양광.풍력 복합발전용 PCS시스템 제어특성분석)

  • 정영석;유권종;강기환;송진수;김홍성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • 본 논문은 배터리 충방전 제어기를 가지는 독립형 태양광·풍력 복합발전시스템에 대해서 기술한다. 복합발전시스템의 주요 전력원은 일반적으로 태양전지 어레이, 풍력발전, 배터리로 구성된다. 태양광·풍력 복합발전시스템은 기상조건의 상호 보완성 때문에 풍력 또는 태양광을 단독으로 이용하는 것에 비해서 배터리 수요를 줄일 수 있으며, 자연에너지의 활용도를 높이는 장점이 있다. 제안된 복합발전시스템은 충방전 제어기가 포함되어 있어 태양전지 어레이의 최대출력에서 동작할 수 있도록 순시치 제어기로 설계하였다. 본 논문에서는 실험을 통하여 시스템의 동작특성을 검증하였다.

Optimization for High Efficiency of Point Contact Solar Cell (후면전극형 태양전지의 고효율화를 위한 최적화 연구)

  • Ahn, Byoung-Sub;Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.345-350
    • /
    • 2011
  • This paper was carried about optimization for high efficiency of point contact solar cell. We have studied on the characteristics of power converter according to each parameter for the optimization for high efficiency of point contact solar cell on this study. We have 25.1352% of convert efficiency after adapt optimal parameters as mentioned in point body and superior conclusion is drawn by comparison with general efficiency has within 20%. At this time, the value of parameter is 100 um cell pitch, 0.01 um AR coating, 0.9 um N+ FSF thickness., etc. This study will continue to go on for optimization for efficiency in future, as it looks now, the results of this study would contribute to the business of high efficiency of point contact solar cell.

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

Influence of (Ga,Al) : ZnO Window Layer Thickness on the Performance of CIGS Thin Film Solar Cells ((Ga,Al):ZnO 투명전극층의 두께에 따른 CIGS 박막 태양전지의 성능 변화 연구)

  • Cha, Jung-Hwa;Jeon, Chan-Wook
    • Current Photovoltaic Research
    • /
    • v.5 no.1
    • /
    • pp.28-32
    • /
    • 2017
  • In this paper, (Ga,Al):ZnO layers were deposited by sputtering to evaluate the device performance according to the thickness of the layer. As the thickness increased, low transmittance was observed, but the electrical resistance was improved. On the other hand, the highest efficiency was recorded at 400 nm device than a 500 nm of it. Therefore, since the critical thickness exists, it is necessary to set an adequate TCO layer thickness in consideration of the characteristics of the underlying film and the device.

Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant (대규모 태양광 발전설비를 위한 전력변환기 개발)

  • Kang, Ho-Hyun;Jung, Hong-Ju;Kim, Wang-Mun;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

A Photovoltaic Device Model for Grid-connected PV System Simulation (계통연계형 태양광발전시스템의 태양광전지모델 시뮬레이션)

  • Campbell, Ryan;Kim, Hak-Man;Lee, Jong-Su;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.18-19
    • /
    • 2006
  • The recent interest in distributed generation (DG) due to the opening of the electricity market and the need for alternatives to conventional fossil fuel-based electricity generation has created renewed interest in grid-connected photovoltaic(PV) systems. Many studies are being performed at the power system level to examine the impacts of grid-connected PV systems and several models for PV arrays have been proposed in the literature. However, the complexity of these models and difficulties of implementing them in various software programs can be deterrents to their use. This paper proposes a robust and flexible PV device model suitable for dynamic and transient studies where the PV array's non-linear DC characteristics are important. The model's implementation in software is straightforward and it can even be constructed using standard software library components, as demonstrated using PSCAD/EMTDC.

  • PDF