• Title/Summary/Keyword: photovoltaic characteristics

Search Result 732, Processing Time 0.024 seconds

Domestic Technical Standards and Performance Test of Photovoltaic PCS for Renewable Energy (신재생에너지용 태양광 PCS 국내 기술기준 및 성능시험)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.479-484
    • /
    • 2018
  • This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)-Characteristics of the utility interface. This standard tests utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1)voltage, current and frequency, 2)normal voltage operating range, 3)DC injection, 4)normal frequency operating range, 5)harmonics and 6)waveform distortion, 7)power factor of PV inverter. Therefore in this paper each test item of domestic technical standard is studied and analyzed and finally full tested by PV inverter performance function.

Recent trends in photovoltaic industries (태양광 발전의 최근 업계 동향)

  • ;;;;;A. U. Ebong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.1
    • /
    • pp.93-107
    • /
    • 1997
  • A solar cell is a device which converts solar energy into electricity without any polluting by-product. Solar cells are useful when they are connected together to form modules. Total production of PV modules worldwide jumped 20 % in 1995 to reach a new record 84.8 MW. In this paper, the recent market trends in photovoltaic industries, principles and characteristics of solar cells and photovoltaic systems are reviewed.

  • PDF

DC Ground Fault Detection System for Photovoltaic Generation (태양광 발전용 직류 지락 검출장치)

  • Jang, Su-Jin;Lee, Jeong-Min;Kim, Wang-Moon;Goo, Tae-Hong;Suh, In-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.408-411
    • /
    • 2008
  • In this paper, a new DC ground fault detection system is proposed, which is suitable for photovoltaic power generation systems. The proposed ground fault systems is superposition of divide resistance and detection circuit. The proposed system has the characteristics of a simplified structure, reduced cost and volume compared with those of the conventional ground fault system for DC source. The operation principle of the proposed systems is described and verified by simulation result.

  • PDF

A Novel MPPT using Single Sensor for Photovoltaic Module Integrated Converter (단일 센서를 사용한 태양광 Module Integrated Converter의 최대전력점 추종 기법)

  • Ji, Young-Hyok;Kim, Young-Ho;Jung, Doo-Yong;Lee, Su-Won;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.263-266
    • /
    • 2009
  • In the photovoltaic applications, MPPT(maximum power point tracking) method is essential due to the non-lineality of photovoltaic output characteristics. To ensure stable tracking response, two sensors are required in conventional popular MPPTs. In modularized PV system as an AC module system, the cost of a sensor can have an effect on entire system cost because a power conditioning device is connected in a PV module. Because only a current sensor is required for proposed MPPT, it is helpful in the cost reduction point of view. In this paper, a novel MPPT using current sensor is proposed In the proposed MPPT, the voltage is derived from sensed current value. The proposed method is verified by simulation results.

  • PDF

Performance Evaluation of the Wall-Type BIPV System Based on the Energy Consumption Unit - A Study for University Lecture Building - (에너지 소비 원단위를 기초로 한 벽면부착형 BIPV 시스템의 성능평가에 관한 연구 - 대학교 강의동 건축물을 대상으로 -)

  • Lee, Kang-Guk;Seo, Won-Duck;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.25-32
    • /
    • 2011
  • The building integrated photovoltaic(BIPV) system has a double advantage that it reduces costs for exterior materials and PV panels. It allows the construction of a low-energy building without the need for the additional installation space. At the construction planning stage, however, it requires sufficient evaluation on the efficiency and performance. This study was performed to promote the distribution of photovoltaic power generation system by estimating the potential photovoltaic power generation capacity of the BIPV system installed on the university lecture building and by evaluating the characteristics and performances of window, spandrel and combined attachment types via the simulation of generation capacity per unit area.

  • PDF

Islanding Detection by Harmonic Current Injection Method for Utility Interactive Photovoltaic System (고조파 주입에 의한 계통연계형 태양광발전시스템의 고립운전 검출)

  • 고재석;채영민;강병희;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.199-210
    • /
    • 2003
  • In this paper, the new Islanding detection method is studied for utility interactive photovoltaic system(UIPVS). It describes the brief of UIPV system and the features of islanding phenomenon. The new islanding detection method for improving the detection characteristics, HCIM(Harmonic Current Injection Method), is proposed and analyzed. The impedance curve of AC load is derived from the complex power equation for testing Islanding detection features. The proposed detection method and the derivation of islanding condition we verified by the simulation with ACSL and the laboratorial experiments.

Efficiency characteristics analysis of residential PV System (주택용 태양광발전시스템의 성능비교 분석)

  • LEE K. Y.;CHOI Y. O.;BAEK H. L.;CHO G. B.;Lee S. G.;KIM D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.144-146
    • /
    • 2004
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Electrochemical Synthesis of Compound Semiconductor Photovoltaic Materials

  • Yu, Bong-Yeong;Jeon, Byeong-Jun;Lee, Dong-Gyu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.11.1-11.1
    • /
    • 2010
  • As one of the non-vacuum, low temperature fabrication route, electrochemical synthesis has been focused for pursuing the cost-effective pathway to produce high efficiency photovoltaic devices. Especially the availability to form the thin film structure on flexible substrate would be the great advantage of electrochemical process. The successful synthesis of the most favorable absorber materials such as CdTe and CIGS has been reported by many researchers, however, the efficiency of electrochemically synthesized could not exceed that from vacuum process, because of microstructural controllability and compositional variation on devices. In this study, we represent the effect of process parameters on the microstructure and composition of compound semiconductor during the synthesis, and propose the photovoltaic characteristics of electrochemically synthesized solar cells.

  • PDF

Effects of Carrier Mobility on Photocurrent Generation in $TiO_2/Poly$(alkylthiophene) Photovoltaic Devices

  • Song, Mi-Yeon;Kim, Kang-Jin;Kim, Dong-Young
    • Macromolecular Research
    • /
    • v.14 no.6
    • /
    • pp.630-633
    • /
    • 2006
  • In heterojunction photovoltaic devices of $ITO/TiO_2/poly$(3-alkylthiophene)/Au, the photo current was characterized at different temperatures for different alkyl chain lengths and regioregularities: regiorandom, regioregular poly(3-hexylthiophene), and regioregular poly(3-dodecylthiophene). The regioregularity and alkyl chain length affected the photovoltaic characteristics due to differences in hole-carrier transportation. The drift charge mobilities of these devices were analyzed by the space-charge-limited current theory using the relation between the dark current and the bias voltage. The photocurrent in the devices based on poly(3-alkylthiophene)s decreased rapidly below the temperature at which the drift charge mobility was $10^{-5}\;cm^2/V{\cdot}s$.

Operating Characteristics of Photovoltaics System for Chosen University Dormitory (조선대학교 기숙사 전원용 PV 시스템의 운전특성)

  • Park J.M.;Choi Y.O.;Lee K.Y.;Oh G.G.;Cho G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.564-566
    • /
    • 2006
  • This paper presents experimental operation with utility interactive 50kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF