• Title/Summary/Keyword: photometer

Search Result 120, Processing Time 0.027 seconds

On-Line Real Time Soil Sensor

  • Shibusawa S.
    • Agricultural and Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.45-49
    • /
    • 2003
  • Achievements in the real-time soil spectro-photometer are: an improved soil penetrator to ensure a uniform soil surface under high speed conditions, real-time collecting of underground soil reflectance, getting underground soil color images, use of a RTK-GPS, and all units are arranged for compactness. With the soil spectrophotometer, field experiments were conducted in a 0.5 ha paddy field. With the original reflectance, averaging and multiple scatter correction, Kubelka-Munk (KM) transformation as soil absorption, its 1st and 2nd derivatives were calculated. When the spectra was highly correlated with the soil parameters, stepwise regression analysis was conducted. Results include the best prediction models for moisture, soil organic matter (SOM), nitrate nitrogen ($NO_3-N$), pH and electric conductivity (EC), and soil maps obtained by block kriging analysis.

  • PDF

Green Synthesis of Silver and Gold Nanoparticles Using Lonicera Japonica Flower Extract

  • Nagajyothi, P.C.;Lee, Seong-Eon;An, Minh;Lee, Kap-Duk
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.8
    • /
    • pp.2609-2612
    • /
    • 2012
  • A simple green method was developed for rapid synthesis of silver and gold nanoparticles (AgNPs and AuNPs) has been reported using Lonicera japonica flower extract as a reducing and a capping agent. AgNPs and AuNPs were carried out at $70^{\circ}C$. The successful formation of AgNPs and AuNPs have been confirmed by UV-Vis spectro photometer, fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), energy dispersive X-ray Analysis (EDAX), scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM). To our knowledge, this is the first report where Lonicera japonica flower was found to be a suitable plant source for the green synthesis of AgNPs and AuNPs.

Study on Construction of a Distribution Photometer (배광측정기 제작에 관한 연구)

  • 김용완;김홍기;이인원;이완순;이상원
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.26-33
    • /
    • 1996
  • 광원에 대하여 서로 다른 여러개의 각도방향에서 광원을 바라볼 때 관측되는 광도분포 및 재귀반사성능을 측정하기 위해 광도분포 측정장치(배광측정기)를 제작하였다. 이 장치는 광원을 좌우로 360도, 상하로 $\pm$30도 회전시킬 수 있는 광원회전장치, 광검출기로 광전자중배관(PM Tube)을 쓰는 수광부 및 재귀반사성능 측정용 투광기와 제어 및 표시부로 구성되어 있다. 광도 측정범위는 0.01-199900 cd , 관측각범위은 0.2-1.5도 이고 광도의 측정오차는 $\pm$3% 이다. 제작된 장치의 구조와 성능평가결과가 제시되었다.

  • PDF

Development of a multi-channel clinical chemistry analyzer (반사광을 이용한 다채널 임상화학분석기개발)

  • 유동주;송은영
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.139-148
    • /
    • 1995
  • In this paper we report the device of a multi-channel clinical instrument developed for determi¬nation of the levels of the urinary urobilinogen, glucose, ketone, bilirubin, protein, ascorbic acid, nitrite, pH, occult-blood, specific gravity, and leukocytes semiquantitatively. The test parameters are expressed on the dry test strips as a range of color intensities by chemical reactions. The instrument measures the value of each substance by reading the reflectance light emanated from the test strips. We also designed the reagent strip cassette and loader in order to intercept the outside interference. The loader can be operated semi-automatically. The light source is consisted on light emitting diodes at three specific wavelengths (560 nm, 610 nm, 650 nm). Precision of the system was evaluated by testing a series of commercial control urine samples. Furthermore, the performance of the instrument was compared with two other test methods on the urine samples from 100 persons. Our results showed a good repeatability between tests and a satisfactory agreement between the readings by our instrument and visual evaluation.

  • PDF

천체 망원경의 자동화 : I. 컴퓨터 제어와 자동 관측을 위한 기본 설계 및 하드웨어의 제작

  • Gang, Yong-U;Lee, Hyeong-Mok;Yun, Gap-Su
    • Publications of The Korean Astronomical Society
    • /
    • v.6 no.1
    • /
    • pp.62-75
    • /
    • 1991
  • The small sized telescope can be best used if the control and observation can be made remotely and fully automatically by the aid of computers. We discuss the possible ways of automating the existing telescopes of various designs using personal computers. 'We have specifically designed the parts necessary to automate 16 inch Cassegrain Telescope at Pusan University Observatory. The degree of automation we have set for the present work is the interactive. remote observation including opening and shutting down of dome slit. The observational modes we have in mind are photoelectric photometry and CCD imaging. The basic components of the hardware are interface card for 16 or 32 bit IBM PC family of computers, relay switches for the control of telescope movements, stepping motor controller card for the control of observational equipments, and AID converter unit that accepts signal from sensors for the environment conditions such as temperature, wind speeds, precipitation, etc. We also have designed and built a photoelectric photometer that can be fully controlled by the command of a computer. Such observational equipment is also essential in order that the remote observation can be realized.

  • PDF

Development of Clinical Chemistry Analyzer with the Dry Reagent Strip(I) (건습시약 스트립을 사용한 임상화학분석장치 개발[I])

  • Yoo, Dong-Joo;Jung, Tae-Hwa;Min, Hong-Kee;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.299-306
    • /
    • 1992
  • For quantitative measurement of reflected light from a clinical diagnostic scrip, a prototype of reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate re(leclance parameters. The strop was illuminated at $45^{\circ}C$ through optical fiber and the intensity of reflected light was determined at rectangulat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/dl about glucose, a saturation state of absorbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

A Study on Clinical Chemistry Analyzer Development by Using the Reflected Visible Light (가시 반사광을 이용한 임상화학 분석장치 개발의 기초연구)

  • Yoo, Dong-Joo;Jung, Tea-Hwa;Min, Hong-Kee;Huh, Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.144-147
    • /
    • 1992
  • In this paper, we study about reflectance photometer for measuring teflectance changes on reagent strip material after applying of a liguid sample. To obtain more accurate reflectance parameter, the strip loader and cassette is designed. The system is designed to work with IBM personal computer. As the experimental results, reflectance level measured of korean standard color paper and shows a exponentially proportion to brightness of paper. A diagnostic strip for total protein is applied to our system and shows a good correlation in a physically protein concentration range.(up to 500 mg/dl).

  • PDF

Novel Measurement method for Image Sticking based on Human Vision System

  • Park, Gi-Chang;Lee, Jong-Seo;Souk, Jun-Hyung;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1478-1481
    • /
    • 2007
  • This paper introduced a measurement method for image sticking based on human vision perception. Existing image sticking quantification method is mostly different from visible level by human perception. It takes a long time to measure image sticking which is degraded by time due to using a spot photometer, therefore many test samples could not be evaluated in a given short period of time in mass production line. However, the new measurement method in this paper is possible to evaluate a large quantity of samples in fast and high correlation with human perceptual level of image sticking.

  • PDF

Influence of Parasitic Capacitance on the Measurement of CCFL & EEFLs

  • Kim, Ga-Eul;Kang, Mi-Jo;Lee, Min-Kyu;Jin, Dong-Jun;Jeong, Hee-Suk;Kim, Jin-Shon;Kim, Jung-Hyun;Koo, Je-Huan;Hong, Byoung-Hee;Kang, Juneg-Ill;Choi, Eun-Ha;Cho, Guang-Sup
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1607-1610
    • /
    • 2007
  • The measurement technology of the electrical and optical properties of CCFL and EEFL for LCD-BLU is investigated. The lamp current and voltage are affected by the leakage of parasitic capacitance. The methods using the photometer and the integrating sphere are compared to determine the lamp efficiency.

  • PDF