• Title/Summary/Keyword: phasor

Search Result 184, Processing Time 0.024 seconds

Two Terminals Numerical Algorithm for Distance Protection, Fault Location and Acing Faults Recognition Based on Synchronized Phasors

  • Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin;Radojevic Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • This paper presents a new numerical algorithm for fault location estimation and for faults recognition based on the synchronized phasors. The proposed algorithm is based on the synchronized phasor measured from the synchronized PMUs installed at two-terminals of the transmission lines. In order to discriminate the fault type, the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. The results of the proposed algorithm testing through computer simulation are given.

Meter Optimal Placement in Measurement System with Phasor Measurement Unit (페이저 측정 시스템의 측정기 최적배치)

  • Kim, Jae-Hoon;Cho, Ki-Seon;Kim, Hoi-Cheol;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1195-1198
    • /
    • 1999
  • This paper presents optimal placement of minimal set of phasor measurement units(PMU's) and observability of measurement system with PMU. By using the incidence matrix symbolic method which directly assigns measurement and pseudo-measurement to incidence matrix, it is much simpler and easier to analyze observability. The optimal PMU set is found through the simulated-annealing(SA) and the direct combinational method. The cooling schedule parameter which is suitable to the property of problem to solve is specified and optimal placement is proven by presented direct combinational method. Search spaces are limited within reasonable feasible solution region to reduce a unnecessary one in the SA implementation based on global search. The proposed method presents to save CPU time and estimate state vectors based on optimal PMU set.

  • PDF

Time Dependent Fourier Transform, Time Dependent Spectrum Density 및 그의 응용

  • 안수길
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.4
    • /
    • pp.1-5
    • /
    • 1976
  • Spectrum의 시간기복을 나타내는 시간 및 주파수의 함수 F(w,t,T) 및 W(w,t,T)를 정의하였고, 실례에 적용시켰다. Fourier변환을 f(t)와 Phasor ejwt와의 Correlation으로 정의하였고 그 변환시분이 시간마다의 성분의 합계이어서 t 시각에서의 Spectrum을 그 근거에서의 f(t)값에만 의함을 증명하였다. Two new time functions defining Time Dependent Fourier Transform F(w,t,T) and Time Dependent Spectrum Density W(w,t,T) are deduced. courier transform is defined as the correlation between the time function f(t) and phasor ejwt. Several theorems corncerning the new functions are proved in order to verify the instantaneous cause a effet of the function f(t) and the nuctuating spectrum.

  • PDF

A study on the Estimation Technique of Frequency in the Power System using Digital Signal Processing (디지털 신호처리기법을 이용한 전력계통 주파수 추정 기법에 관한 연구)

  • Nam, S.B.;Park, C.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.175-177
    • /
    • 2001
  • Frequency and phasor are the most important quantities in power system operation. Frequency reflects the dynamic energy balance between load and generating power. To estimate of power system frequency, an accurate digital tracking algorithm by using phasor angle difference is presented. For an evaluation of the proposed technique, simulations by EMTP have been performed. Test results were showed the algorithm's accuracy under the effect of noise and changes in frequency and amplitude on the input signal.

  • PDF

Design and characteristics analysis of Double resonant type High frequency Inverter using Phasor shift (복 공진형 고주파 인버터의 특성해석과 설계)

  • Kim, Jong-Hae;Won, Jae-Sun;Kim, Dong-Hee;Cho, Kyu-Phan;Sim, Kwang-Yul;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2100-2102
    • /
    • 1998
  • A full bridge double resonant type inverter using Phasor shift suitable for heating magnetic and nonmagnetic at high frequency is described. A series-parallel arrangement of capacitor is adopted and optimum mode of operation is proposed. Also, Based on the characteristics value, a method of circuit design is proposed.

  • PDF

Phasor Analysis of Sensorless Vector Control System Model for Induction Motor (유도전동기 센서리스 벡터제어 시스템 모델의 페이저 해석)

  • Lee, H.J.;Hwang, J.H.;Seong, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2015-2017
    • /
    • 1998
  • This paper deals with the design of a field oriented control system model for the high performance induction motor using Matlab with Simulink. The proposed control system model, which is not used the speed and flux sensor, contains IM model, Tranformation, Decoupling, FFOC(Field Flux Orientation Controller), Torque calculator and PI Controller to control speed, torque. Results present the stator and rotor flux phasor trajectory, the startup and transient response of speed, torque and stator current with field oriented control and the response to changes in reference speed with no load. This paper shows that the propose control system is more robust than other vector control system, and suggest the enchanced model, using Matlab with Simulink for the high performance in induction motor control.

  • PDF

A Numerical Algorithm for Fault Location Estimation Considering Long-Transmission Line (장거리 송전선로를 고려한 사고거리추정 수치해석 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2139-2146
    • /
    • 2008
  • This paper presents a numerical algorithm for fault location estimation which used to data from both end of the transmission line. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs(Phasor Measurement Units) in the time-domain. This paper has separated from two part of with/without shunt capacitance(short/long distance). Most fault was arc one-ground fault which is 75% over [1]. so most study focused with it. In this paper, the numerical algorithm has calculated to distance for ground fault and line-line fault. In this paper, the algorithm is given with/without shunt capacitance using II parameter line model, simple impedance model and estimated using DFT(Discrete Fourier Transform) and the LES(Least Error Squares Method). To verify the validity of the proposed algorithm, the EMTP(Electro- Magnetic Transient Program) and MATLAB did used.

Modeling of a Transfer Function for Frequency Controlled Resonant Inverters

  • Han, Mu-Ho;Lee, Chi-Hwan;Kwon, Woo-Hyun
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.567-574
    • /
    • 2009
  • A linear transfer function for the output current control of frequency-controlled resonant inverters is proposed in this paper. The circuit of resonant inverters can be transformed into two coupled circuits through the complex phasor transform. The circuits consist of cross-coupled power sources and passive elements. The circuits are used to induce the state space equation, which is transformed into the $4^{th}$ order cross-coupled transfer function. The $4^{th}$ order cross-coupled transfer function is modeled into a $2^{nd}$ order linear transfer function based on a behavior analysis of the pole and zero locations that facilitate a simple and intuitive linear transfer function. The feasibility and validity of the proposed linear transfer function were verified by simulation and experiment.

Algorithm for Detecting, Indentifying, Locating and Experience to Develop the Automate Faults Location in Radial Distribution System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.36-44
    • /
    • 2010
  • This paper presents the design of an algorithm to detect, identify, and locate faults in radial distribution feeders of Provincial Electricity Authority (PEA). The algorithm consists of three major steps. First, the adaptive algorithm is applied to track/estimate the system electrical parameter, i.e. current phasor, voltage phasor, and impedance. Next process, the impedance rule base is used to detect and identify the type of fault. Finally, the current compensation technique and a geographic information system (GIS) are applied to evaluate a possible fault location. The paper also shows the results from field tests of the automate fault location and illustrates the effectiveness of the proposed fault location scheme.

Advanced Distance Relaying of on a Double Circuit Transmission Line (병행 2회선 송전선로의 개선된 거리계전기법)

  • Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.