Two Terminals Numerical Algorithm for Distance Protection, Fault Location and Acing Faults Recognition Based on Synchronized Phasors  

Lee Chan-Joo (Dept. of Electrical Engineering, Konkuk University)
Park Jong-Bae (Dept. of Electrical Engineering, Konkuk University)
Shin Joong-Rin (Dept. of Electrical Engineering, Konkuk University)
Radojevic Zoran (Dept. of Electrical Engineering, Konkuk University)
Publication Information
Journal of Electrical Engineering and Technology / v.1, no.1, 2006 , pp. 35-41 More about this Journal
Abstract
This paper presents a new numerical algorithm for fault location estimation and for faults recognition based on the synchronized phasors. The proposed algorithm is based on the synchronized phasor measured from the synchronized PMUs installed at two-terminals of the transmission lines. In order to discriminate the fault type, the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. The results of the proposed algorithm testing through computer simulation are given.
Keywords
Arc resistance; Fault location; Protection; PMUs (Phasor Measurement Units); Spectral analysis; Transmission lines;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chan-Joo Lee, Zoran Radojevic, Joong-Rin Shin, Jong-Bae Park 'Numerical Algorithm for Fault Location Calculation and Blocking Unsuccessful Reclosing onto Permanent Faults', IEEE Proceeding, June 2005
2 T. Funabashi, H. Otoguro, Y. Mizuma, L. Dube, M. Kizilcay and A. Ametani, 'Influence of Fault Arc Characteristics on the Accuracy of Digital Fault Locators', IEEE Trans. on Power Delivery, Vol. 16, pp. 195-199, April 2001   DOI   ScienceOn
3 A. T. Johns, R. K. Aggarwal and Y. H. Song, 'Improved Technique for Modeling Fault Arc on Faulted EHV Transmission Systems', IEE Proc.-Gener. Transm. Distrib., Vol. 141, pp. 148-154, March 1994
4 A. S .Maikapar, 'Extinction of an Open Electric Arc', Elektrichestvo, Vol. 4, pp. 64-69, 1960
5 T. Takagi, et al., 'Development of a New Fault Locator Using the One-Terminal Voltage and Current Data', IEEE Trans. on PAS, Vol. PAS-101, No. 8, pp. 2892-2898, August 1982   DOI   ScienceOn
6 Ying-Hong Lin, Chih-Wen Liu, Ching-Shan Chen, 'A New PMU-Based Fault Detection/Location Technique for Transmission Line with Consideration of Arcing Fault Discrimination-Part II: Performance Evaluation', IEEE Trans. on Power Delivery, Vol. 19, No. 4, pp. 1594-1601, Oct. 2004   DOI   ScienceOn
7 L. Eriksson, M. Saha, and G.D. Rockfeller, 'An Accurate Fault Locator with Compensation for Apparent Reactance in the Fault Resistance Resulting from Remote-End Infeed', IEE Trans. on PAS, Vol. PAS-104, No. 2, pp. 424-436, Feb. 1985
8 M. Sant and Y. Paithankar, 'On Line Digital Fault Locator for Overhead Transmission Line', IEE Proceedings, Vol. 126, No. 11, pp. 1181-1185, Nov. 1979
9 Ying-Hong Lin, Chih-Wen Liu, Ching-Shan Chen, 'A New PMU-Based Fault Detection/Location Technique for Transmission Line with Consideration of Arcing Fault Discrimination-Part I: Theory and Algorithms', IEEE Trans. on Power Delivery, Vol. 19, No. 4, pp. 1587-1593, Oct. 2004   DOI   ScienceOn
10 Chi-Shan Yu, Chih-Wen Liu, Sun-Li Yu, and Joe-Air Jiang, 'A New PMU-Based Fault Location Algorithm for Series Compensated Lines', IEEE Trans. on Power Delivery, Vol. 17, No. 1, pp. 33-46, Jan. 2002   DOI   ScienceOn