• 제목/요약/키워드: phase-to-ground fault

검색결과 144건 처리시간 0.024초

병행 2회선의 T분기 선로 고장점 표정 알고리즘 (Fault Location Algorithm for Parallel Transmission Line with a Teed Circuit)

  • 권영진;강상희;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.49-51
    • /
    • 2000
  • This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line. This algorithm uses only local end voltage and current information. Remote end and fault currents are calculated by using distribution factors. To reduce load current effect, negative sequence current is used. EMTP simulation result have shown effectiveness of the algorithm under various conditions.

  • PDF

소프트웨어 Fault Tolerance를 이용한 고장점 표정 (Fault Location Identification Using Software Fault Tolerance Technique)

  • 김원하;장용원;한승수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권2호
    • /
    • pp.73-78
    • /
    • 2005
  • The management of technological systems will become increasingly complex. Safe and reliable software operation is a significant requirement for many types of system. So, with software fault tolerance, we want to prevent failures by tolerating faults whose occurrences are known when errors are detected. This paper presents a fault location algorithm for single-phase-to-ground faults on the teed circuit of a parallel transmission line using software fault tolerance technique. To find the fault location of transmission line, we have to solve the 3rd order transmission line equation. A significant improvement in the identification of the fault location was accomplished using the N-Version Programming (NVP) design paradigm. The delivered new algorithm has been tested with the simulation data obtained from the versatile EMTP simulator.

YBCO 박막을 이용한 3상 6.6kV 항형 초전도 한류기의 동시Quench 분석 (Simultaneous Quench Analysis of a Three-Phase 6.6 kV Resistive SFCL Based on YBCO Thin Films)

  • 심정욱;김혜림;현옥배
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.46-51
    • /
    • 2004
  • We fabricated a resistive type superconducting fault current limiter (SFCL) of 3-phase $6.6 kV_{rms}$ / rating, based on YBCO thin films grown on sapphire substrates with a diameter off inch. Each element of the SFCL was designed to have the rated voltage of $600 V_{rms}$ $/35A_{rms}$. The elements produced a single phase with 8${\times}$6 components connected in series and parallel. In addition, a NiCr shunt resistor of 23 $\Omega$ was connected in parallel to each of them for simultaneous quenches between the elements. Prior to investigating the performance of the 3 phase SFCL, we examined the quench characteristics for 8 elements connected in series. For all elements, simultaneous quenches and equal voltage distribution within 10% deviation from the average were obtained. Based on these results, performance of the SFCL for single line-to-ground faults was investigated. The SFCL successfully limited the fault current of $10 kA_{ rms}$ below 816 $A_{peak}$ within 0.12 msec right after the fault occurred. During the quench process, average temperature of all components did not exceed 250 K, and the SFCL was totally safe during the whole operation.

  • PDF

A Study on the Gustafson-Kessel Clustering Algorithm in Power System Fault Identification

  • Abdullah, Amalina;Banmongkol, Channarong;Hoonchareon, Naebboon;Hidaka, Kunihiko
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1798-1804
    • /
    • 2017
  • This paper presents an approach of the Gustafson-Kessel (GK) clustering algorithm's performance in fault identification on power transmission lines. The clustering algorithm is incorporated in a scheme that uses hybrid intelligent technique to combine artificial neural network and a fuzzy inference system, known as adaptive neuro-fuzzy inference system (ANFIS). The scheme is used to identify the type of fault that occurs on a power transmission line, either single line to ground, double line, double line to ground or three phase. The scheme is also capable an analyzing the fault location without information on line parameters. The range of error estimation is within 0.10 to 0.85 relative to five values of fault resistances. This paper also presents the performance of the GK clustering algorithm compared to fuzzy clustering means (FCM), which is particularly implemented in structuring a data. Results show that the GK algorithm may be implemented in fault identification on power system transmission and performs better than FCM.

154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향 (An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation)

  • 조성수;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

고온 초전도 한류기가 설치된 전력 시스템의 안정도 해석 (Stability Analysis of Power System Instal1ed Superconducting Fault Currnt Limiter)

  • 이승제;이찬주;이창열;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.346-348
    • /
    • 1998
  • The stability of Power system installed Hi-Tc Superconducting Fault Current Limiter(SFCL) is analyzed as a process of developing SFCL. In interpretation, simple mimic system(only one motor) is assumed and then the circuit with SFCL in system is solved. In case the SFCL is installed in Power system, it protected synchronization more effectively both in symmetrical 3-phase fault and single phase line to ground fault.

  • PDF

초고압 GIS 접지시스템에서 낙뢰 및 고장에 의한 과도특성 해석 (Transient Characteristics of GIS Grounding Systems by Lightning and Fault)

  • 이형수;심건보;김정훈;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.77-79
    • /
    • 1995
  • In performing lightning and fault studies in GISs, it is of great importance to accurately model the conductor network consisting of the grounding systems and overhead conductor structures. In particular, the overhead grounded pipe enclosures of the GIS should be appropriately modelled. In this paper, the overhead pipe enclosures of a 500 kV $SF_6$ breaker and substation grounding system are presented in detail. During a phase-to-ground fault, scalar potentials and electromagnetic fields are computed at different frequencies for various conductor network configurations is defined by varying the number of conductors used to represent the pipes at different frequencies are obtained. Such knowledge will be very useful in reducing computation time for a transient ground potential rise study which will be performed in the future.

  • PDF

동기 발전기의 평형 및 불평형 고장해석 (Balanced and Unbalanced Fault Analysis of Synchronous Generator)

  • 박철원;안준영;이종수;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.402-404
    • /
    • 2006
  • In this paper, we simulated transient-state under fault in stator windings of synchronous generator. The fault types are line to ground fault, line to line short fault, and three phase short fault. For fault analysis of generator system, the voltage equation of a synchronous machine using the two-axis theory was used. It can be used to analyze important features of faults and to develop enhanced protection methods.

  • PDF

아크지락사고에 대한 사고 판별 및 적응 재폐로 기법 (Identification of Arcing Fault and Development of An Adaptive Reclosing Technique about Arcing Ground Fault)

  • 김현홍;추성호;채명석;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.354-356
    • /
    • 2006
  • This paper presents a new one-terminal numerical algorithm for fault location estimation and for faults recognition. The proposed algorithm are derived for the case of most frequent single-phase line to ground fault in the time domain. The arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent of transient. In this paper the algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm the Electro-Magnetic Transient Program(EMTP/ATP) is used.

  • PDF

신경회로망과 고장전류의 변화를 이용한 고장판별 알고리즘에 관한 연구 (A Study on the Algorithm for Fault Discrimination in Transmission Lines using Neural Network and the Variation of Fault Currents)

  • 여상민;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.405-411
    • /
    • 2000
  • When faults occur in transmission lines, the classification of faults is very important. If the fault is HIF(High Impedance Fault), it cannot be detected or removed by conventional overcurrent relays (OCRs), and results in fire hazards and causes damages in electrical equipment or personal threat. The fast discrimination of fault needs to effective protection and treatment and is important problem for power system protection. This paper propolsed the fault detection and discrimination algorithm for LIFs(Low Impedance Faults) and HIFs(High Impedance Faults). This algorithm uses artificial neural networks and variation of 3-phase maximum currents per period while faults. A double lines-to-ground and line-to-line faults can be detected using Neural Network. Also, the other faults can be detected using the value of variation of maximum current. Test results show that the proposed algorithms discriminate LIFs and HIFs accurately within a half cycle.

  • PDF