• Title/Summary/Keyword: phase only filter

Search Result 169, Processing Time 0.028 seconds

Comparing Feature Selection Methods in Spam Mail Filtering

  • Kim, Jong-Wan;Kang, Sin-Jae
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.17-20
    • /
    • 2005
  • In this work, we compared several feature selection methods in the field of spam mail filtering. The proposed fuzzy inference method outperforms information gain and chi squared test methods as a feature selection method in terms of error rate. In the case of junk mails, since the mail body has little text information, it provides insufficient hints to distinguish spam mails from legitimate ones. To address this problem, we follow hyperlinks contained in the email body, fetch contents of a remote web page, and extract hints from both original email body and fetched web pages. A two-phase approach is applied to filter spam mails in which definite hint is used first, and then less definite textual information is used. In our experiment, the proposed two-phase method achieved an improvement of recall by 32.4% on the average over the $1^{st}$ phase or the $2^{nd}$ phase only works.

  • PDF

An Efficient Design Method of Linear-Phase Prototype Lowpass Filter for Near-Perfect Reconstruction Pseudo-QMF Banks (근접 완전재생 Pseudo-QMF 뱅크를 위한 선형위상 프로토타입 저역통과 필터의 효율적인 설계 방법)

  • Jeon, Joon-Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3C
    • /
    • pp.271-280
    • /
    • 2008
  • M channel near-perfect-reconstruction(NPR) pseudo-QMF banks are a hybrid of conventional pseudo-QMF design and spectral factorization approach where the analysis and synthesis filters are cosine-modulated versions of the prototype-lowpass filter(p-LPF). However, p-LPF H(z) does not have linear-phase symmetry as well as magnitude-distortion optimization since it is obtained by spectral factorization of $2M^{-th}$ band filter $G(z)=z^{-(N-1)}H(z^{-1})H(z)$. A fair amount of attention, therefore, has been focused on the design of filter banks for reducing only alias-cancellation distortion without reconstructed-amplitude distortion. In this paper, we propose a new method for designing linear-phase p-LPF in NPR pseudo-QMF banks, which is based on Maxflat(maximally flat) FIR filters with closed-form transfer function. In addition, p-LPF H(z) is optimized in this approach so that the 2M-channel overall distortion response represented with $G(z)=H^2(z)$ approximately becomes an unit magnitude response. Through several examples of NPR pseudo-QMF banks, it is shown that the peek ripple of the overall magnitude distortion is less than $3.5{\times}10^{-4}\;({\simeq}-70dB)$ and analysis/synthesis filters have the sharp monotone-stopband attenuation exceeding 100 dB.

An Effective Crossover Filter Choice of Multi-Way Loudspeaker System (멀티웨이 스피커 시스템의 효과적인 크로스오버 필터 선택)

  • Kang, Seong-Hoon;Jung, Han-Kyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.184-190
    • /
    • 2014
  • Although it is ideal that the sound with the range of 20 ~ 20,000 Hz is produced by the loudspeaker system composing of only one loudspeaker unit, it is almost impossible now. Therefore, the audible frequency range is now produced by the loudspeaker system, which is consisted of more than two loudspeaker units. The multi-way loudspeaker system certainly requires a crossover filter, which is divided the audible frequency into low and high frequency ranges. The crossover frequency of filter usually is in the range of 1 ~ 4 kHz, the frequency range can largely affect to the sound articulation and quality. It is an example that the phase and amplitude at the crossover frequency can be different from each other, due to the variously reasons. Conversely, they can not produce the smooth frequency response due to the different distance between the two loudspeaker units and electrical properties. As a result, the sound articulation and quality can be degraded. Therefore, the phase and amplitude response at the crossover frequency has to be deeply considered, in order to exactly match the woofer and tweeter. In this study, it is proposed the methods which are the flat frequency and phase response to be obtained by adjusting of the delay time between loudspeaker units, and the choice of filter to be considered the roll-off properties of each unit. It is achieved the frequency response with ${\pm}1$ dB, and the sound articulation is also improved.

Performance Analysis of VDL Mode-2 Transceiver and Generation of the Narrow Band Digital Modulated Signals (VDL Mode-2 송·수신기 성능분석 및 협대역 디지털 변조신호 생성)

  • Gim, Jong-Man;Kim, Tae-Sik;Kim, In-Kyu;Kim, Hyoun-Kyoung
    • Journal of Advanced Navigation Technology
    • /
    • v.11 no.1
    • /
    • pp.9-16
    • /
    • 2007
  • In this paper, the Bit Error Ratio (BER) performances of the D8PSK modulation schemes for VDL Mode-2 are analyzed according to the matched and unmatched cases of the channel filters. The carrier frequency and phase offset effects are analyzed with unmatched case. Generally in digital transmission techniques, the Root Raised Cosine filters which are used as channel filters are applied to both sides at transmitter and receiver in order to achieve no ISI, but in VDL Mode-2, the Raised Cosine Filter is used only in transmission section and the receiver section uses general low pass filter, therefore we could not achieve ISI reduction effects but can have better spectrum quality. From the simulation results, the error probability is increased slightly (1~2dB) with use of un-matched channel filter, we got the conclusions that carrier phase offset do not effect to bit error ratio, but the frequency offset effect is so serious. Finally, narrow band D8PSK modulation signals are generated by the use of Digital Up-Converter and then its features are compared with analog modulator.

  • PDF

Simplified HPLC Method for the Determination of Pseudoephedrine Hydrochloride from Allegra D Tablet

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.15 no.2
    • /
    • pp.123-126
    • /
    • 2007
  • A sensitive, simple and highly selective liquid chromatography method of determination for extraction of pseudoephedrine hydrochloride from Allegra D tablet was developed. The chief benefit of the present method is the minimal sample preparation, as the procedure is only filtering through pore syringe filter. Two drugs (pseudoephedrine hydrochloride, fexofenadine) were separated on a C$_{18}$ column and analyzed by high performance liquid chromatography (HPLC). The method had a chromatographic run time of 8.0 min. 1 ml of pseudoephedrine hydrochloride solution (1 mg/ml) was filtered through 0.22 um pore syringe filter. 50 ul of filtering solution was injected to HPLC pump and we knew the retention time (1.85 min) of separating of pseudoephedrine hydrochloride using UV detector at 280 nm. We used C$_{18}$ column (4.6 mm${\times}$250 mm), mobile phase solution (<0.05 mol/L NaH$_2$PO$_4$, 2 ml/L H$_3$PO$_4$>/CH$_3$CN / sodium dodesyl sulfate = 60 ml / 40 ml / 1 g). We separated psedoephedrine hydrochloride at run time of 1.85 min from Allegra D tablet solution (1 mg/ml) filtered through 0.22 um pore syringe filter using UV detector at 280 nm. Flow rate was set at 1.0 ml/min and the column temperature was set at 40$^{\circ}C$. Psedoephedrine hydrochloride solution (1 mg/ml) separated from Allegra D tablet was filtered through 0.22 um pore syringe filter and injected 50 ul. We confirmed the peak of psedoephedrine hydrochloride at same retention time and the separating solution was freeze-dried. In conclusion, A simple isocratic reverse-phase HPLC method has been developed that provides excellent separation of pseudoephedrine from Allegra D tablet.

A New Control Method for Single-Phase Active Power Line Contioners (단상 능동 전력 조절 장치를 위한 새로운 제어기법)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.155-158
    • /
    • 2000
  • A new control method for single-phase shunt active power line conditioners(APLC's) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtraction the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of he load current and the source only supplies the fundamental component,. Experimental results on a prototype verify the feasibility of the presented scheme,

  • PDF

Fault Diagnosis for Open-Phase Faults of PMSM Drives Using EKF (영구자석 동기전동기 확장형 칼만필터를 이용한 개방성 고장진단 기법)

  • Ahn, Sung-Guk;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.452-453
    • /
    • 2010
  • This paper proposes a novel diagnosis scheme using Extend Kalman Filter (EKF), especially, in subject to the open-phase faults of the inverter switches. The stator resistances of PMSM are estimated by the EKF in real time. The proposed diagnosis scheme is implemented without any extra devices. Moreover, since it uses a simple algorithm by analyzing only estimated stator resistances of each phase, the detection speed becomes fast. The feasibility of the proposed fault diagnosis scheme is proved by several simulation and experimental results.

  • PDF

A Single-Phase Unified Power Quality Conditioner with a Frequency-Adaptive Repetitive Controller

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.790-799
    • /
    • 2018
  • This paper proposes a single-phase unified power quality conditioner (S-UPQC) for maintaining power quality issues in a microgrid. The S-UPQC can compensate the voltage and current harmonics, voltage sag, and swell as a dynamic voltage restorer (DVR), regardless of variations in the grid frequency. Odd harmonics are treated as even-order harmonics in a rotating frame to implement the harmonic compensators with only one repetitive controller (RC) without any harmonic extractor. The dynamic performance is improved and the delay time is reduced in the RC. The S-UPQC control scheme is designed to maintain accurate and stable operation under deviations of the grid frequency by using the Lagrange interpolation-based finite-impulse-response (LIFIR) filter approximation method. The proposed control schemes were validated through a simulation and experiment.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Reduction of DC-Link Capacitance in Single-Phase Non-Isolated Onboard Battery Chargers

  • Nguyen, Hoang Vu;Lee, Sangmin;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.394-402
    • /
    • 2019
  • This paper proposes a single-phase non-isolated onboard battery charger (OBC) for electric vehicles (EVs) that only uses small film capacitors at the DC-link of the AC-DC converter. In the proposed charger, an isolated DC-DC converter for low-voltage batteries is used as an active power decoupling (APD) circuit to absorb the ripple power when a high-voltage (HV) battery is charged. As a result, the DC-link capacitance in the AC-DC converter of the HV charging circuit can be significantly reduced without requiring any additional devices. In addition, some of the components of the proposed circuit are shared in common for the different operating modes among the AC-DC converter, LV charging circuit and active power filter. Therefore, the cost and volume of the onboard battery charger can be reduced. The effectiveness of the proposed topology has been verified by the simulation and experimental results.