• Title/Summary/Keyword: phase difference

Search Result 3,110, Processing Time 0.03 seconds

Comparison of VUF using Resistor & Inductive Load (저항성 및 유도성 부하의 운전시 전압불평형율의 비교)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Jong-Han;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1062-1064
    • /
    • 2005
  • 3 phase 4-wire system has been widely used in the customer's application due to merit of 1 bank construction of loads such as 1-phase lighting, heat and 3-phase motor. But if the load distribution is not uniformed by the operation conditions, voltage unbalance is highly appeared by the difference of each phase current value. Especially, if the linear load such as resistance or inductive load has different power factor value, voltage unbalance factor is not the same due to the phase angle and magnitude of each phase voltage. In this paper, we composed the measurement device and analyzed by varying of load pattern.

  • PDF

Comparison of the kinematic analysis of grand battement Jeté á la seconde in center between skilled and unskilled ballet majors (발레 숙련도에 따른 센터에서 Grand Battement Jeté á la seconde 동작의 운동학적 비교 분석)

  • Youm, Chang-Hong;Park, Young-Hoon;Seo, Kook-Woong;Yang, Chung-Mo
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.153-166
    • /
    • 2004
  • The purpose of this study was to investigate time of the phase, angle of the right ankle, knee, and hip joint, lateral angle of the trunk, mediolateral displacement of COM, and vertical displacement of COM between two groups while executing grand battement $jet{\acute{e}}$ $\acute{a}$ la seconde in a center exercise setting through 3D video analysis. The subjects participated in this study were skilled and unskilled 6 female ballet majors in Busan, respectively. The conclusions are as follows: 1. The time of the phase 2 was faster than P3. It shows a significant difference(p<.05) for P1 and P4 between skilled and unskilled groups 2. The angle of He right ankle joint has a significant difference(p<.05) at E4 between skilled and unskilled groups. The angle of the right knee joint has no significant difference at all events between skilled and unskilled groups. The angle of the right hip joint has a significant difference(p<.001) at E3 between skilled and unskilled groups. 3. The lateral angle of the trunk has a significant difference(p<.05) at E1 and at E5 between skilled and unskilled groups. The skilled group of the lateral angle of the trunk was lower than the unskilled group. However the skilled group's lateral angle of the trunk was bigger than the unskilled group at E3. It has significant difference(p<.001) at E3 between skilled and unskilled groups. 4. The mediolateral displacement of COM has no significant difference at all events between skilled and unskilled groups. The vertical displacement of COM has a significant difference(p<.01) at E3 between skilled and unskilled groups.

Evaluation of difference in respiratory phase between amplitude- and phase-based four-dimensional computed tomography (위상 기반 사차원전산화단층촬영과 진폭 기반 사차원전산화단층촬영 영상에서의 위상차 평가)

  • Lee, So Hyang;Park, Soo Yeon;Kim, Jong Sik;Choi, Byung Ki;Park, Hee Chul;Jung, Sang Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.73-78
    • /
    • 2015
  • Purpose : Under the assumption of change to the amplitude based sorting, the study will use four dimensional computed tomography imaging (4DCT) arrayed using the phase based sorting to analyze the respiratory phase difference. Materials and Methods : The study analyzed the 4DCT (4-dimensional computed tomography) images of 10 liver cancer patients that were treated with respiratory gated radiotherapy from 2015 February to March. Using RPM respiratory gating (RPM 1.7.5, Varian, USA) equipment, imaging according to respiratory cycle of phase based sorting was acquired and using a treatment planning system (Pinnacle 9.2, Philips, USA) the acquired imaging according to respiratory cycle was used to measure the abdominal movement value by respiratory cycle. The measuring point was the point where the center point of the Marker Block and the body surface met in the 50% phase image and here the coordinate values Lateral, Vertical, Longitudinal (X, Y, Z) were set as reference points, and on the X, Z plane identical to the reference point, using the identical method the Y axis coordinate value of each 0%, 30%, 40%, 50%, 60%, 80% phase images were acquired to quantitatively measure the variation of distance to the Y axis. The abdominal movement value according to respiration was applied to the theoretical model that the value decreases linearly from maximum inhalation to maximum exhalation to divide the variation of my value to predict as amplitude value by respiratory cycle and conversely the variation in amplitude was recalculated with the phase variation deviation value to analyze. Results : The deviation value between expected value and actual location was the largest in the 30% phase with 0.24 cm, and standard deviation was also the largest in 30% phase with 0.13 cm. The effective value of the deviation value derived from the average of the deviation squared value of each patient appeared as minimum 0.7 cm, maximum 0.18 cm, average 0.12 cm, and standard deviation 0.4 cm. Also by dividing the actual movement distance value with the peak expiration value then converting it into %Phase, the deviation value with actual phase 16.5% in 30% phase, 10.0% and 40% phase, 10.0% and 60% phase, 15.4% and 80% phase, and overall average about 13%, and arraying based on amplitude, phase shift occurred and further it was from peak expiration the chance of deviation occurrence was increasingly measured. Conclusion : Based on the results of the study there were differences between value acquired based on theoretical model and actual value. Therefore in respiratory gated radiotherapy using external surrogates, there needs to be establishment of respiration gated radiation system that avoids the combination of two Sorting methods considering that there will be occurrence of treatment and corresponding clinical differences due to the phase difference that occur due to the Amplitude based Phase Sorting.

  • PDF

Aerodynamic Study on Phase Difference of Fore-and Hind-wing of a Dragonfly-type Model (잠자리 유형 모델의 앞,뒤 날개 위상차에 대한 공력연구)

  • 김송학;장조원;송병흠
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.11
    • /
    • pp.18-25
    • /
    • 2006
  • Unsteady aerodynamic force measurements were carried out in order to investigate the effects of phase difference of a dragonfly-type model with two pairs of wing. A load-cell was employed to measure the aerodynamic force generated by a plunging motion of the dragonfly-type model. The dragonfly-type model has a dynamic similarity with real one, and incidence angles of fore- and hind-wing are 0° and 10°, respectively. Other experimental conditions are as follows: The freestream velocity was 1.6 m/sec and corresponding chord Reynolds number was 2.88×103, and phase differences of fore- and hind-wing were 0°, 90°, 180° and 270°. The variation of aerodynamic coefficients during one cycle of the wing motion is presented. Results show that the lift is generated during the downstroke motion and the drag generated during the hind-wing‘s downstroke motion with the lift generation.

Preconditioned Jacobian-free Newton-Krylov fully implicit high order WENO schemes and flux limiter methods for two-phase flow models

  • Zhou, Xiafeng;Zhong, Changming;Li, Zhongchun;Li, Fu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.49-60
    • /
    • 2022
  • Motivated by the high-resolution properties of high-order Weighted Essentially Non-Oscillatory (WENO) and flux limiter (FL) for steep-gradient problems and the robust convergence of Jacobian-free Newton-Krylov (JFNK) methods for nonlinear systems, the preconditioned JFNK fully implicit high-order WENO and FL schemes are proposed to solve the transient two-phase two-fluid models. Specially, the second-order fully-implicit BDF2 is used for the temporal operator and then the third-order WENO schemes and various flux limiters can be adopted to discrete the spatial operator. For the sake of the generalization of the finite-difference-based preconditioning acceleration methods and the excellent convergence to solve the complicated and various operational conditions, the random vector instead of the initial condition is skillfully chosen as the solving variables to obtain better sparsity pattern or more positions of non-zero elements in this paper. Finally, the WENO_JFNK and FL_JFNK codes are developed and then the two-phase steep-gradient problem, phase appearance/disappearance problem, U-tube problem and linear advection problem are tested to analyze the convergence, computational cost and efficiency in detailed. Numerical results show that WENO_JFNK and FL_JFNK can significantly reduce numerical diffusion and obtain better solutions than traditional methods. WENO_JFNK gives more stable and accurate solutions than FL_JFNK for the test problems and the proposed finite-difference-based preconditioning acceleration methods based on the random vector can significantly improve the convergence speed and efficiency.

Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography (입사 표면 선량 계산에 따른 진단용 X-선 촬영시 피폭선량 비교 연구)

  • Han, Jae-Bok;Choi, Nam-Gil;Sung, Ho-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.357-363
    • /
    • 2011
  • The aim of this study is to compare radiation dose in diagnostic X-ray radiography and calculated by different mathematical equation. The result of ESDs direct measurement and that calculated by Mori NDD-M shows the biggest difference. On the other hand, equation by Edmonds shows the lowest difference of ESDs. Also, Rectification due to the difference between direct dose measurement and calculation method commutated three-phase, single phase and inverter type, show less difference in the drive way. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic x-ray radiography.

GAS-LIQUID TWO-PHASE HOMOGENEOUS MODEL FOR CAVITATING FLOW -Part II. HIGH SPEED FLOW PHENOMENA IN GAS-LIQUID TWO-PHASE MEDIA (캐비테이션 유동해석을 위한 기- 2상 국소균질 모델 -제2보: 기-액 2상 매체중의 고속유동현상)

  • Shin, B.R.;Park, S.;Rhee, S.H.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.91-97
    • /
    • 2014
  • A high resolution numerical method aimed at solving cavitating flow was proposed and applied to gas-liquid two-phase shock tube problem with arbitrary void fraction. The present method with compressibility effects employs a finite-difference 4th-order Runge-Kutta method and Roe's flux difference splitting approximation with the MUSCL TVD scheme. The Jacobian matrix from the inviscid flux of constitute equation is diagonalized analytically and the speed of sound for the two-phase media is derived by eigenvalues. So that the present method is appropriate for the extension of high order upwind schemes based on the characteristic theory. By this method, a Riemann problem for Euler equations of one dimensional shock tube was computed. Numerical results of high speed flow phenomena such as detailed observations of shock and expansion wave propagations through the gas-liquid two-phase media and some data related to computational efficiency are made. Comparisons of predicted results and solutions at isothermal condition are provided and discussed.

A Symbol Synchronization Detection by Difference Method for OFDM Systems (차분방법에 의한 OFDM 심볼 동기검출 방식)

  • Joo Chang-Bok;Park Nam-Chun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.56-65
    • /
    • 2006
  • In this paper, we introduce modified difference type symbol timing detection method of simple structure and show the relations between S/N ratio and timing detection performance which less influenced by multipath channel delay profile and added noise level and it show very exact GI detection performance characteristics. In the computer simulations, 4 symbol time duration of short and long training of IEEE802.11a standard OFDM frame are used for symbol synchronization timing detection. The computer simulation results show the very exact symbol timing detection performance characteristic within 1 sample error of OFDM signal regardless channel delay profile from minimn phase channels of phase rotation ${\pi}/2$ to non-minimum phase channels of phase rotation ${\pi}/2$ of received OFDM signal and added noise level in channel.

The Comparison of the Perceived Needs between Patients with Cancer, their Caregivers, and Nurses According to the Cancer Patient,s Phases of Illness (질병단계에 따라 암환자, 돌보는 가족원, 간호사의 간호요구 지각 비교)

  • 양영희
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.787-795
    • /
    • 1997
  • This descriptive study was conducted to ascertain whether the needs of patients with cancer, their caregivers and their nurses changed according to the illness phases and if the perceived needs of the three groups were different for three categories of nursing needs. At two hospitals in Seoul and Choongnam, three groups of subjects, -patients with cancer(79), caregivers(92), and nurses(72) - responded to a questionnaire consisting of items on educational need(11 items), physical need(8 items), emotional need(9 items) using a 4-point Likert scale. The patients and caregivers were selected according to the phase of the cancer (initial, intermediate or recurred, terminal phases). Finding revealed that the level of perception and degree of satisfaction of the needs were low, just around two points in patients and caregivers. Of the three categories of needs, physical needs were received the highest score and the degree of satisfaction of physical needs was also the highest. There was no significant difference between the level of perception and satisfaction of needs in patients and caregivers according to the phases of the illness and the degree of per reception and the satisfaction of the patients were not significantly different and caregivers showed the same result. There was a significant difference in the level of importance of the needs of nurses according to the phases of the cancer. They perceived emotional needs were the most important in first phase and second phase, physical needs in third phase and the educational needs were more important in the first phase than in any other phase. The degree of importance of needs was significantly lower than the degree to which needs were addressed, according to the nurses response. In a comparison of patient and caregiver's perceived degrees of need, and need satisfaction, and nurse's perceived degree of need provision, patient and caregiver scores were lower than the nurses.

  • PDF

Inhibitory Effect of adding Phase Change Material (PCM) to Fire Fighter Protective Clothing on Burn Injuries (Phase Change Material (PCM) 소재 적용 소방보호복의 화상발생 억제효과에 관한 연구)

  • Lee, Jun Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.16-22
    • /
    • 2016
  • Fire fighters rely on fire fighter protective clothing (FFPC) to provide adequate protection in the various hazardous environments. To enhance its protection performance, the FFPC material must be thick and thus it is difficult to achieve weight reduction. One of the methods of overcoming this problem, the addition of phase change material (PCM) to FFPC, is a new technology. In previous studies, the researches was mostly related to the temperature characteristics of the fibers incorporating PCM, but little information is available about its effect on burn injuries. Thus, in this study, the inhibitory effects of adding PCM to FFPC on second degree burns were investigated through numerical calculations. Thermal analyses of biological tissues and FFPC with embedded PCM exposed to several fire conditions causing severe tissue damage were studied by using a finite difference method based on the Pennes bio-heat equation. FFPC with embedded PCM was found to provide significantly greater protection than conventional fire fighting clothing, because the heat of absorption due to the phase change within the material is used to limit the heat conduction of the material.