• Title/Summary/Keyword: phase controller

Search Result 1,377, Processing Time 0.027 seconds

The speed control of the Single-Phase induction motor using P-I controller (비례 - 적분 제어기를 이용한 단상 유도 전동기의 속도 제어)

  • Sang, Doo-Whan;Cheong, Dal-Ho;Kim, Jung-Chul;Oh, Min-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.603-605
    • /
    • 1994
  • The Single-Phase induction motor is widely used in home appliances, especially refrigerator, air conditioner and washing machine. Recently many home appliances that use the motor require the speed control to get the various and convenient functions for the customers. Generally it is so hard to control the speed of the Single-Phase induction motor and to get the wide range of the speed variation. In this raper, the speed controller using P-I is designed for the Single-Phase induct ion Motor. The experimental results of the phase controller using P-I show the wide speed control of the Single-Phase induction motor and rebuff control to load change.

  • PDF

Controller Design of Utility-connected Single-phase Inverter using d-q Theory (d-q이론을 이용한 개통 연계형 단상 인버터 제어기 설계기법)

  • Park, Chang-Joo;Kim, Chang-Hyun;Kim, Myung-Chul;Choi, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1247-1249
    • /
    • 2003
  • Despite many advantages, d-q theory was available only for three phase system. But recently, some papers proposed the application methods of d-a theory or similar theories for single phase systems. This paper presents the control method of the utility-connected single-phase inverter using d-q theory. The suggested method gives single-phase system instantaneous controllability and also makes the realization of APF(Active Power Filter) without DFT operation and PFC(Power Factor Controller) possible. This paper deals with utility-connected single phase inverter with PFC function. The controller was verified by simulation tool.

  • PDF

Autonomous Underwater Vehicles with Modeling and Analysis of 7-Phase BLDC Motor Drives

  • Song, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.932-941
    • /
    • 2014
  • In this paper, a simulation model for 7-phase BLDC motor drives for an Autonomous Underwater Vehicles (AUV) is proposed. A 7-phase BLDC motor is designed and the electrical characteristics are analyzed using FEA program and the power electronics drives for the 7-phase BLDC motor are theoretically analyzed and the actual implementation has been accomplished using Matlab Simulink. PI controller and fuzzy controller are compared for verifying the validity of the proposed model and the informative results are described in detail. Especially A fuzzy controller is used to characterize 7-phase BLDC motor, drive systems under normal and fault operating conditions.

Analysis of Proportional Control for Grid Connected Inverter With LCL Filter

  • Windarko, Novie Ayub;Lee, Jin-Mok;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.247-249
    • /
    • 2008
  • There are many types of grid-connected inverter controllers; Synchronous Reference Frame (SRF)-based controller is the most popular methods. SRF-based controller is capable for reducing both of zero-steady state error and phase delay. However, SRF-based controller has a complex algorithm to apply in real application such as digital processor. Resonant controller is also reduced zero-steady state error, but its transfer function has a high order. In this paper, a simple proportional control is applied for grid connected inverter with LCL filter. LCL filter is a third order system. Applying a simple proportional controller is not increased the order of closed loop transfer function. By this technique, the single phase model is easily obtained. To reduce steady state error, proportional gain is set as high as possible, but it may produce instability. To compromise between a minimum steady state error and stability, the single phase model is evaluate through Root Locus and Bode diagram. PSIM simulation is used to verify the analysis.

  • PDF

Research on grid connected 3-phase inverter appling repetitive controller in d-q axis (d-q축에서 반복제어기를 적용한 3상 계통연계형 인버터연구)

  • Lim, J.W.;Cho, Y.H.;Cheo, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.151-152
    • /
    • 2015
  • This paper is research on design controller of grid connected 3-phase inverter. It confirms effects of high harmonics on controller and imposes repetitive controller to minimize effects on the high harmonics. The result of test in this paper is drawn by simulation tool.

  • PDF

The Development of Velocity Ripple Controller Using Active Phase Compensation (능동형 위상보정을 이용한 정밀 속도리플 제어기의 개발)

  • Kang, Seok Il;Jeong, Jae Hyeon;Kim, Jung Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.265-272
    • /
    • 2017
  • Velocity ripple in manufacturing processes reduces productivity and limits the precision of the product. In practice, the frequency and phase of velocity ripples always change minutely, which makes it impossible to compensate for the ripple by simply inserting an opposite feed-forward signal in the system. In this study, an active-phase compensation algorithm was developed to enable the velocity-ripple controller to track the phase change of the ripples in real time. The proposed controller can compensate for the velocity ripple whatever its cause, including disturbance by the torque ripple. The algorithm consists of three functional modules: the velocity-ripple extractor, the synchronized integrator, and the phase shifter. Experimental results showed that the proposed controller clearly reduces velocity ripples with phase variation.

Study on Capacity Design of Active Phase Controller for Distribution Line Reconfiguration (배전선로 재구성을 위한 능동위상제어기의 용량 선정 연구)

  • Jeong, Da-Woom;Kim, Soo-Yeon;Park, Sung-Jun;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.369-375
    • /
    • 2020
  • Distribution energy resources have been increasing in recent years. However, output power is limited for distribution network stability. This study proposes an active distribution network that can reconfigure distribution lines by using an active phase controller. A conventional distribution network has a fixed structure, whereas an active distribution network has a variable structure. Therefore, the latter can increase the output power of distribution energy resources and decrease the overload of distribution line facilities. An active phase controller has two operation modes for minimizing circulating current during dynamic reconfiguration. In this study, voltage and current control algorithms are proposed for active phase controllers. The simulation of the proposed methods for active phase controllers is performed using PSIM software.

Anti-Windup Scheme to Control DC Voltage of Three-Phase Four-Wire Active Power Filter (누적방지 기법을 적용한 3상 4선식 능동전력필터 시스템의 직류전압 제어)

  • 정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.128-136
    • /
    • 2003
  • This paper investigates the application of the anti-windup scheme to control U voltage of the three-phase four-wire active power filter, installed in a three-phase four-wire power system. In order to reduce efficiently the harmonic currents caused by the switching loads and to improve the whole performance of the flower system, the DC voltage of the three-phase four-wire active power filter should be properly controlled. PI controller can be applied to the U voltage controller of the three-phase four-wire active power filter. However, a large error input to PI controller leads to a windup phenomenon which deteriorate the dynamic characteristics of the U voltage controller Therefore, the application of the anti-windup scheme for the DC voltage controller is proposed and the improved performances of the anti-windup U voltage controller are proved through the computer simulation study.

PWM-VSI controller of Three-phase UPS Using Stationary Reference Frame (정지좌표계를 이용한 3상 UPS용 PWM-VSI 제어)

  • Kim M.K.;Kim J.S.;Bang S.S.;Choi J.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.965-968
    • /
    • 2003
  • This paper describes the PWM-VSI controller of three-phase UPS system using stationary reference frame. This controller meets the specification the UPS inverter output voltage even under the unbalanced or nonlinear load. This controller is also constructed with duble control loop of the outer voltage control loop and the inner current control loop. For the fast response of the output voltage control, yhr inner current control loop of the capacitor current os used. To get the good property against overshoot, the If controller us used. The outer voltage controller is designed with P controller and the high gain transfer function is used for the zero steady state error. All control gains of both controller is designed base on the CDM method.

  • PDF

A Study on Effects of Offset Error during Phase Angle Detection in Grid-tied Single-phase Inverters based on SRF-PLL (SRF-PLL을 이용한 계통연계형 단상 인버터의 전원 위상각 검출시 옵셋 오차 영향에 관한 연구)

  • Kwon, Young;Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.73-82
    • /
    • 2015
  • This paper proposes an ripple reduction algorithm and analyzes the effects of offset and scale errors generated by voltage sensor while measuring grid voltage in grid-tied single-phase inverters. Generally, the grid-connected inverter needs to detect the phase angle information by measuring grid voltage for synchronization, so that the single-phase inverter can be accurately driven based on estimated phase angle information. However, offset and scale errors are inevitably generated owing to the non-linear characteristics of voltage sensor and these errors affect that the phase angle includes 1st harmonic component under using SRF-PLL(Synchronous Reference Frame - Phase Locked Loop) system for detecting grid phase angle. Also, the performance of the overall system is degraded from the distorted phase angle including the specific harmonic component. As a result, in this paper, offset and scale error due to the voltage sensor in single-phase grid connected inverter under SRF-PLL is analyzed in detail and proportional resonant controller is used to reduce the ripples caused by the offset error. Especially, the integrator output of PI(Proportional Integral) controller in SRF-PLL is selected as an input signal of the proportional resonant controller. Simulation and experiment are performed to verify the effectiveness of the proposed algorithm.