• 제목/요약/키워드: phase angle deviation

검색결과 53건 처리시간 0.025초

축류터빈에서 끝간격 유동에 의한 편향각과 압력손실의 모형 (Modeling of Deviation Angle and Pressure Loss Due to Rotor Tip Leakage Flow Effects in Axial Turbines)

  • 윤의수;박부룡;정명균
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1591-1602
    • /
    • 1998
  • Simple spanwise distribution models of deviation angle and pressure loss coefficient due to the tip leakage flow are formulated for use in association with the streamline curvature method as a flow analysis. Combining these new models with the previous deviation and loss models due to secondary flow, a robust streamline curvature method is established for flow analysis of single-stage, subsonic axial turbines with wide ranges of turning angle, aspect ratio and blading type. At the exit from rotor rows, the flow variables are mixed radially according to a spanwise transport equation. The proposed streamline curvature method is tested against a forced vortex type turbine as well as a free vortex type one. The results show that the spanwise variations of flow angle, axial velocity and loss coefficients at rotor exit are predicted with good accuracy, being comparable to a steady three-dimensional Navier-Stokes analysis. This simple and fast flow analysis is found to be very useful for the turbine design at the initial design phase.

FIR 필터를 이용한 전력계통의 주파수 추정기법 (Estimation Technique of Frequency using FIR Filter in the Power System)

  • 남시복;박철원;신명철
    • 전기학회논문지P
    • /
    • 제50권3호
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

측면시야각에서의 대칭적 명암대비비 향상을 위한 IPS-LCD 광학보상 (Optical Compensation of IPS-LCD for Symmetric-High-Contrast at Off-Axis Oblique View)

  • 김태현;김봉식;박우상
    • 한국전기전자재료학회논문지
    • /
    • 제29권3호
    • /
    • pp.175-180
    • /
    • 2016
  • In this study, we proposed an optical compensation method to improve the symmetricity of contrast ratio for wide viewing angle IPS (in-plane switching) LCD. First, the phase retardation depending on the thickness of compensation film is calculated, and then the phase change is presented at the $Poincar{\acute{e}}$ sphere. The phase retardation and the polarization state of the light passing through the optical elements are caculated by using the EJMM (extended Jones matrix method). In addition, the transmittance and the contrast countour are also calculated by using the Berremann's $4{\times}4$ matrix method. The simulation is carried out for a IPS LC cell with positive A/C/A compensation film. From the standard deviation of the contrast ratio, we confirmed the symmetricity at each viewing angle is inversely proportional to the standard deviation and calculated the optimum design condition of the uniaxial compensation film for the IPS LCD.

적응진화연산을 이용한 퍼지-전력계통안정화장치 설계 (A Design of Fuzzy Power System Stabilizer using Adaptive Evolutionary Computation)

  • 황기현;박준호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.704-711
    • /
    • 1999
  • This paper presents a design of fuzzy power system stabilizer (FPSS) using adaptive evolutionary computation (AEC). We have proposed an adaptive evolutionary algorithm which uses a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner in order to take merits of two different evolutionary computations. FPSS shows better control performances than conventional power system stabilizer (CPSS) in three-phase fault with heavy load which is used when tuning FPSS. To show the robustness of the proposed FPSS, it is appliedto damp the low frequency oscillations caused by disturbances such as three-phase fault with normal and light load, the angle deviation of generator with normal and light load and the angle deviation of generator with heavy load. Proposed FPSS shows better robustness than CPSS.

  • PDF

A Modified Selective Ground Relay for Ungrounded Distribution Systems

  • Nam Soon-Ryul;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.16-22
    • /
    • 2006
  • Selective ground relays (SGRs) are useful fur distinguishing a faulted feeder from the sound feeders in ungrounded systems. However, they sometimes mis-operate due to human or device errors. Particularly, the reversed polarity of zero-sequence current transducers (ZCTs) is the most frequent cause of mis-operation. This paper presents a modified SGR for reducing the probability of mis-operations caused by the reversed polarity of ZCTs. The modification is achieved by introducing an adaptive time delay, which depends on the magnitude of the zero-sequence current and the phase angle deviation from the reference. The modified SGR was successfully demonstrated on a sample ungrounded system without mis-operation.

축류터빈의 동익에서 끝간격 누설유동에 의한 편향각과 압력손실의 모형화 (Modeling of Deviation Angle and Pressure Loss due to Rotor Tip Leakage Flow in Axial Turbines)

  • 윤의수;오군섭;정명균
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1998년도 제10회 학술강연회논문집
    • /
    • pp.13-13
    • /
    • 1998
  • A simple model of the tip leakage flow models of the rotor downstream flow is developed, based on Lakshminarayana's theoretical concept on the tip clearance flow and the experimental data published in open literature. And new spanwise distribution models of deviation angle and pressure loss coefficient due to the tip leakage flow are formulated for use in association with the streamline curvature method as a through flow analysis. Combining these new models and previous deviation and loss models due to secondary flow, a robust streamline curvature method is established for flow analysis of single-stage, subsonic axial turbines with wide ranges of turning angle, aspect ratio and blading type. At the exit from rotor rows, the flow variables are mixed radially according to a spanwise transport equation. The proposed streamline curvature method is tested against a forced vortex type turbine as well as a free vortex type one. The results show that the spanwise variations of flow angle, axial velocity and loss coefficients at rotor exit are predicted with good accuracy, being comparable to a steady three-dimensional Navier-Stokes analysis. This simple and fast flow analysis is found to be very useful for the turbine design at the initial design phase.

  • PDF

위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정 (Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta)

  • 김문선;권대철
    • 한국자기학회지
    • /
    • 제26권4호
    • /
    • pp.142-148
    • /
    • 2016
  • 자기공명영상에서 위상대조(phase contrast; PC) 기법으로 혈류 속도와 혈류량을 정량적으로 측정하기 위해 VENC(150 cm/s)에서 숙임각의 변화에 따른 혈류 속도와 혈류량을 측정하였다. 1.5T MRI로 지원자 17명(여: 8, 남: 9, 평균연령 $57.9{\pm}15.4$)을 대상으로 non-breath holding 기법을 적용하여 상행대동맥에서 VENC(150 cm/s)로 숙임각을 $20^{\circ}$, $30^{\circ}$, $40^{\circ}$ 변화하여 측정하였다. 혈류는 average velocity, peak velocity, net forward volume, net forward volume/body surface area를 획득하였다. 상행대동맥에서 AV(average velocity)의 평균값은 숙임각 $20^{\circ}$(9.87 cm/s), $30^{\circ}$(9.6 cm/s), $40^{\circ}$(10.05 cm/s)로 측정되었다. 숙임각을 $20^{\circ}$, $30^{\circ}$, $40^{\circ}$에서 peak velocity, average velocity, net forward volume, net forward volume/body surface area는 통계적인 유의한 차이가 없었다(p > .05). 혈류속도와 혈류량 측정은 매개변수를 조정하여 적용하면 심장혈관 질환의 진단 및 치료에 중요한 정보가 되는 혈류량을 정확히 계산하고, 혈류량 측정에 관한 연구에 도움을 줄 수 있다.

FIR 필터를 이용한 전력계통 주파수 추정기법에 관한 연구 (A Study on the Estimation Technique of Frequency in the Power System using FIR Filter)

  • 남시복;이훈구;박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.80-85
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Frequency of a power system remains constant if sum of all the loads plus losses equals total generation in the system. However, the frequency starts to decrease if total generation is less than the sum of loads and tosses. On the other hand, the system frequency increases if total generation exceeds the sum of loads and losses. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this Constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the power system energy balance. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR(finite duration impulse response) filter, a phase angle of a voltage. The rate change of the phase angle is used for estimation and speed in its process. Also, to confirm the validity of the proposed algorithm, the simulation results obtained by using EMTP(electro magnetic transients program) are shown.

  • PDF

세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석. (Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.43-57
    • /
    • 1992
  • 위상감지법(phase detector technique)은 세포의 막 캐패시턴스(membrane capacitance)를 실시간적으로 측정할 수 있는 유일한 방법이나 측정이 행해지는 동안 세포의 상태가 끊임없이 변화하기 때문에 피할 수 없는 측정오차가 존재한다. 본 연구는 이 오차의 근원을 분석하여 위상감지법의 실용한계를 규정하고자 하였다. 이론적 분석에 기초하여 다음과 같은 사실을 밝힐 수 있었다. 1) access conductance와 membrane conductance의 변화에 기인하는 측정오차를 줄이기 위해서는 초기 위상치를 올바로 선택하여야 한다. 2) 이 때 세포를 여기시키기 위해 인가하는 전압의 주파수를 알맞게 선택하여야 한다. 3) 그러나 초기 위상치가 정해진 이후의 위상 변화는 막 캐패시턴스의 측정에 큰 영향을 미치지 않는다. 4) 초기 위상을 적절히 선택하였다 하더라도 세포외 분비시 막 캐패시턴스가 크게 증가하는 경우에는 비례상수에 오차가 발생한다. 이 때 발생하는 오차는 측정기간 동안 비례상수를 되풀이하여(iteration) 보정함으로써 방지할 수 있다. 이상의 결과는 향후 위상감지법을 사용할 때 유용한 설용한계를 제공하리라 생각된다.

  • PDF

765kV 비연가 송전선로에서 상간단락고장 시어 거리계전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Phase Short Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-phase short fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-phase short fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kv untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF