• Title/Summary/Keyword: phase angle

Search Result 2,003, Processing Time 0.03 seconds

A Kinematical Analysis of Side Kick Motion in Taekwondo (태권도 옆차기 동작의 운동학적 분석)

  • Park, Kwang-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.49-63
    • /
    • 2003
  • For this study, four male university Taekwondo players were randomly chosen, between the weight categories of 60Kg and 80Kg. Their side kicks (yeop chagi), which are part of foot techniques, were kinematically analyzed in terms of the time, angle, and angular velocity factors involved with the kicks through the three-dimensional imaging. The results of the analysis are as fellows. 1. Time factor The first phase(preparation) was 0.48sec on average, accounting for 60% of the entire time spent; the second phase(the minimum angle of the knee joint) was 0.21sec on average, taking up 26% of the whole time spent; and the third phase(hitting) was 0.11sec on average, representing 14% of the entire time spent. 2. Angle factor In the first phase(preparation), rotating their bodies along the long axis, the players bended their hip and knee joints a lot, by moving fast in the vertical and horizontal directions, in the second phase(the minimum angle of the knee joint), the players continued to extend their bodies along the vertical axis, while pronating their lower legs and bending their hip and knee joints a lot to reduce the radius of gyration, and in the third phase(hitting), they extended their knee joints greatly so that the angle movements of their lower bodies shifted to circle movements. 3. Angular velocity factor In the first phase(preparation), the angular velocity of the hip and knee joints increased. while moving horizontally and rotating the body along the long axis; in the second phase(the minimum angle of the knee joint), the angular velocity increased by bending the hip and knee joints fast to reduce the rotation radios; and in the third phase(hitting), the angular velocity was found to have increased, by rotating the body along the long axis to increase the angular velocity and shifting the angular momentum of the pronated knee joint to the circular momentum.

Study on Switching Angle Characteristic for Optimal Driving Condition of SRM (SRM의 최적운전을 위한 스위칭각 선정에 관한 연구)

  • Oh Seok-Gyu;Lee Sang-Hoon;Kim Chang-Sub;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.231-234
    • /
    • 2001
  • The torque of SRM depends on phase current and the derivative of inductance. But the inductance of SRM is nonlinearly changed according to rotor position angle and phase current because of saturation in magnetic circuit. Therefore this has a concern in torque ripple and speed variation, and it is difficult to control the desired torque The torque of SRM depends on phase current and the derivative of inductance. But the inductance of SRM is nonlinearly changed according to rotor position angle and phase current because of saturation in magnetic circuit, and it is difficult to control the desired torque. This paper proposes an optimization control scheme by adjusting both the turn-on and turn-off angle according to high efficiency points which are simulated by GA-Neural Network, which is used to simulate the reasonable switching angle which is nonlinearly varied with rotor speed and load.

  • PDF

Phase Angle Using Bioelectrical Impedance Analysis for Predicting Survival in Patients with Metastatic Cancer (전이암 환자의 예후 판단 인자로서 생체전기 임피던스 분석을 이용한 위상각의 역할)

  • Yoon, Sung-soo;Yoon, Seong-woo;Ryu, Han-sung;Kim, Eun-hye;Lee, Jee-young
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.463-470
    • /
    • 2018
  • Objectives: The aim of this study was to identify the validity of phase angle as a prognostic factor for survival in patients with metastatic cancer. Methods: Data of patients with metastatic cancer who visited the Korean medicine cancer center at Kyung Hee University Hospital in Gangdong from April 2016 to February 2018 were collected for this study. The values of phase angle (PhA) and blood hemoglobin (Hb), C-reactive protein (CRP), and serum albumin levels were also investigated by bioelectrical impedance analysis (BIA). Results: In total, 86 patients were analyzed. The cut-off value of the phase angle was determined as 5.0. Univariate and multivariate analysis revealed that phase angle (HR 3.15, 95% CI 1.79-5.54) and CRP (HR 2.15, 95% CI 1.24-3.73) predicted survival with statistical significance. The median overall survival of the low PhA group ($PhA{\leq}5.0$) was 1.8 months (95% CI 0.6-2.9 months) and 7.2 months (95% CI 5.2-9.2 months) in the high PhA group (PhA>5.0)(p<0.001). Conclusions: The phase angle could be an independent prognostic factor for patients with metastatic cancer. Further research is required to confirm these findings and their correlation with other indexes.

A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation (배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성)

  • Bang, Ji-Yoon;Kim, Hak-Man;Lee, Bock-Ku;Sim, Jae-Sun;Shin, Myong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

Enhanced Phase Angle Detect Method Using High-pass Filter (고주파 필터를 이용한 개선된 위상각 검출 방법)

  • Heo, Min-Ho;Song, Sung-Gun;Kim, Gwang-Heon;Nam, Hae-Gon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2370-2378
    • /
    • 2009
  • The enhanced phase angle estimation algorithm is essential to supply the power stably under synchronizing with grid source. In this paper, we are proposed the novel phase angle estimation algorithm and verified the validity of proposed method as simulation with PSIM and experiments. We sort the harmonics element using high-pass filter(HPF) that have the cut-off frequency below basic element and make reverse d-q transformation. So, it can be restored the harmonics element at stationary axis, and we can get the fundamental voltage element of AC grid. Proposed PLL method have a rapid responsibility and a large margin at controller design than conventional method because it have a small phase delay and a sufficient controller gain margin. And, it can reduce the error of voltage rms value and axis transformation according to robust PLL algorithm against the harmonic and phase unbalance.

Characteristics of Artificial Earthquake using Recorded Earthquake Data in Korea (국내 지진데이터를 이용한 인공지진가속도 특성)

  • Woo, Woon-Taek;Park, Tae-Won;Jung, Ran
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.479-486
    • /
    • 2003
  • The characteristics of harmonic phase angles and phase angle differences contained in earthquake ground motions such as El Centre 1940 NS, Taft1 1952 NS, Hachinohe 1968 NS and Mexico 1985 are figured, which have been mostly overlooked in contrast with the importance placed on harmonic amplitudes. Recently, performance based design method is used for seismic design and seismic retrofitting, which needs nonlinear response analysis, there must be earthquake ground accelerations which contain the phase angle, the phase angle difference and energy input spectrum characteristics of the zone considered to be constructed building structures. To make clear the importance of phase angle differences, responses of 4 recorded earthquake ground motions, 4-earthquake ground motions normalized by 110 gal and 4 artificial earthquake motions compatible to the seismic building code of Korea are compared.

  • PDF

Novel Third Harmonic Current Injection Technique for Harmonic Reduction of Controlled Converters

  • Eltamaly, Ali M.
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.925-934
    • /
    • 2012
  • Three-phase controlled converters have many applications in the utility interfacing of renewable energy sources and adjustable speed drives as a rectifier or inverter. The utility line currents of these converters have a high harmonic distortion, which is more than the harmonic standards. This paper introduces a new technique for circulating the third harmonic currents from the dc-link to the line currents to reduce their harmonic contents. The proposed system uses a single-phase PWM converter to control the angle and amplitude of the injection current for each of the firing angle of a three-phase converter. A detailed analysis is introduced to achieve a relationship between the firing angle of the three-phase controlled converter and the power angle of the PWM converter. In addition, a detailed design for the other injection path components is introduced. A simulation and experimental work is introduced to prove the mathematical derivations. Analysis, simulation and experimental results prove the superiority of the proposed technique.

The Starting Characteristics of Single Phase Induction Motor by Control of Phase and Voltage (위상각과 전압제어에 의한 단상유도전동기의 기동특성)

  • Sung, K.M.;Park, S.K.;Choi, Y.O.;Cho, G.B.;Oh, K.G.;Baek, H.L.;Park, H.A.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.350-352
    • /
    • 1995
  • The starting characteristics of single phase induction motor(SPIM) is described by control of phase and voltage. Auxiliary winding voltage is controlled by DC amplifier and phase is integrator. These processes enable comparison of torque with slip in each voltage and phase angle variations. Simulation and experimentation results of the motor's torque-slip characteristics using the controlled auxiliary winding voltage and phase angle arc shown and discussed. As a results, starting time is fast and main winding current is small when auxiliary winding voltage is low than rating voltage and starting characteristics is good in phase angle $90^{\circ}$.

  • PDF

Accuracy Improvement of the Estimated Angle Using Phase Averaging in Phase-Comparison Monopulse Algorithm (위상 비교 모노 펄스 알고리즘에서 위상평균법을 이용한 추정 각도 정확도 향상)

  • Cho, Byung-Lae;Lee, Jung-Soo;Lee, Jong-Min;Sun, Sun-Gu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1212-1215
    • /
    • 2012
  • This study describes the accuracy improvement of the estimated angle using phase averaging in phase-comparison monopulse algorithm. In addition, to compensate the time-delay due to the phase averaging, we propose the time-delay compensation algorithm which uses the derivative of the estimated angle. These derivative is calculated by the curve fitting method. Using the real radar interferometer, we have verified that the phase averaging and time-delay compensation algorithms are effective in real-time signal processing application.

A Study on DC-Link Current Ripple of Multi-Phase/Multi-Stage Boost Converter (다상/다단 부스트 컨버터의 DC-Link 리플 전류 분석)

  • Seung-Min Kim;Dong-Hee Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.59-67
    • /
    • 2023
  • This paper explores the variation of DC-Link current ripple analysis in terms of duty cycle and phase angle of Multi-phase/Multi-stage boost converter. A 2-Stage/1-Stage boost converter DC-Link current is used to determine the difference between the 1st stage diode current and the 2nd stage inductor current. Each stage boost converter diode and inductor current is subordinate to the phase angle and duty cycle. The magnitude of the ripple current is variable according to phase angle and duty cycle. The analysis results are verified by variation of DC-Link current ripple using a 1kW typical 2-stage/1-stage boost converter.