• Title/Summary/Keyword: pet

Search Result 4,190, Processing Time 0.036 seconds

Comparison of Mechanical and Interfacial Properties of Carbon Fiber Reinforced Recycled PET Composites with Thermoforming Temperature and Time (열 성형 온도 및 시간에 따른 탄소섬유 강화 재활용 PET 복합재료의 계면 및 기계적 물성 비교)

  • Baek, Yeong-Min;Shin, Pyeong-Su;Kim, Jong-Hyun;Park, Ha-Seung;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.175-180
    • /
    • 2017
  • Currently, since carbon fiber reinforced plastics (CFRPs) are lightweight and have excellent physical properties, their demand has increased dramatically. Many works have studied the CFRPs based on recycled thermoplastics. In this study, the applicability of recycled composite was evaluated using recycled polyethylene terephthalate (PET). PET was collected from waste materials used in beverage bottles and processed to produce PET films. Optimal thermoforming temperature and time were analyzed by comparing the mechanical properties with forming temperature and time difference for producing PET films. CF mat and PET film were used to determine the suitable parameters for the optimum thermoforming of CF/PET composites. The mechanical properties of each thermoforming condition were verified by bending test. The degree of impregnation of the PET film into the CF mat was evaluated by cross-sectional photographs, whereas the interfacial properties were evaluated by interlaminar shear strength (ILSS). Ultimately, it was confirmed that the thermoforming condition for forming the CF/recycled PET composites yielding the optimal mechanical and interfacial properties was at $270^{\circ}C$ for 5 minutes.

Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET (13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가)

  • Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.20-23
    • /
    • 2016
  • Purpose Because of heart movement, PET image of heart is very blur. So, PET scan gated with ECG is necessary to improve a spatial resolution of heart PET image. In this study, we will evaluate a image quality of both gated $^{13}N-ammonia$ PET scan and non-gated one. Materials and Methods Before start a heart PET, we attached a ECG electrode on patients (n = 5, $aged=54{\pm}17$). And we started a list mode PET scan that used by a mCT40 PET/CT (siemens, germany) during 10 minute, injected $^{13}N-ammonia$ ($378{\pm}50MBq$) to a patients at same time. By using this list mode data, we reconstructed both gated PET image and non-gated PET image. Then we analysed a profiles of those images, performed a blind test, and subtracted a gated image on non-gated image. Results FWHM of a gated image is improved about 23% and there is a differency count distribution at a subtracted image from non-gated image to a gated image. But in case of blind test, everybody select the gated image as a better quality among each images. Conclusion As a result, we can find that image quality will improve by using gated PET scan. In additional, we can calculate a EF valve, apply QGS, QPS of PET. Therefore, the gated PET scan help improving an accuracy, applying a more information for a diagnosis.

  • PDF

A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET (국소진행성 유방암에서 F-18 FLT-PET 적용 가능성에 대한 예비 연구: F-18 FDG-PET와 비교)

  • Hyuen, Lee-Jai;Kim, Euy-Nyong;Hong, Il-Ki;Ahn, Jin-Hee;Kim, Sung-Bae;Ahn, Sei-Hyun;Gong, Gyung-Yup;Kim, Jae-Seung;Oh, Seung-Jun;Moon, Dae-Hyuk;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: The aim of this study was to investigate the feasibility of 3 ' -[F-18]fluoro-3 ' -deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2' -deoxy-2 ' -[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. Material & Methods: The study subjects consisted of 22 female patients (mean age; $42{\pm}6$ years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was $7.2{\pm}3.4$ cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. Results: All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and $$SUV_{75} (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; $6.3{\pm}5.2\;vs\;8.3{\pm}4.9$, p=0.02 /$SUV_{75};\;5.3{\pm}4.3\;vs\;6.9{\pm}4.2$, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET($11.7{\pm}7.7\;vs\;6.3{\pm}3.8$, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were $4.2{\pm}1.2\;and\;8.3{\pm}4.9$. The FDG SUVs of liver and bone marrow were $1.8{\pm}0.4\;and\;1.6{\pm}0.4$. Conclusion: The uptakes of FLT were lower than those of FDG, but all patients of this study revealed good FLT uptakes of tumor and lymph node. Because FLT-PET revealed high TB ratio and concordant rate with lymph node uptakes of FDG-PET, FLT-PET could be a useful diagnostic tool in locally advanced breast cancer. But, physiological uptake and individual variation of FLT in bone marrow and liver will limit the diagnosis of bone and liver metastases.

Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT (PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

A Study on the Compound Colors by Cross-Dyeing of Cotton/PET Union Fabrics (면(綿)/PET 교직물(交織物)의 Cross Dyeing에 의한 복합색상(複合色相) 연구(硏究))

  • Lee, Mi-Kyung
    • Journal of Fashion Business
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2007
  • As a part of the study for the materials development of compound feelings, therefore, this study investigated into the effects of the colors of warp and weft on the overall colors of fabrics, along with the visual changes of colors by the measuring angle of both warp and weft, by means of cross-dyeing of cotton/PET union fabrics. First, the dyeing of cotton and PET fabrics individually with the same color, the dyeing of PET fabrics followed by that of cotton fabrics resulted in a small difference in color than the dyeing in the reversed order. Second, in the case of the dyeing of cotton/PET union fabrics with the color of one fiber fixed and that of the other in ten colors, the color of cotton fiber, which is warp, gave much influence. In addition, the color change was remarkable among complementary colors, while it was negligible among adjacent colors. Third, in the case of dyeing of cotton/PET union fabrics with the color of one fiber fixed and that of the other in ten colors, the results were different by the measuring angle. When PET was fixed in green and cotton was dyed in ten colors, color-deepening was observed by the inclination in the direction of warp and weft without the dominance over all colors like cotton. When cotton was dyed in red and PET in ten colors, the color of PET appeared dimly in the horizontal case by the direction of the light, and red appeared as inclined in the direction of warp and weft. This is because of the dominance of cotton color over the overall color, since the density of cotton fiber, the warp of union fabrics, is higher than that of PET, the weft. Thus, this is to be considered in the selection of the warp's color. In view of the above results, the color changes are outstanding when the color of warp dominates the overall color and when the colors of warp and weft are complementary, in comparison with the case when the colors are adjacent. The colors also change by the measuring angle.

A Study on the Characteristic of Sound Absorption of the Polyester Non-Woven Fabrics Used for the Automobile Sound Absorption Material (폴리에스터 부직포를 이용한 자동차용 흡음재의 흡음특성에 관한 연구)

  • 변홍식;이태관
    • Polymer(Korea)
    • /
    • v.25 no.3
    • /
    • pp.427-434
    • /
    • 2001
  • The sound absorption materials With polyester (PET) were prepared for automobile. They consist of 3 layers with different size of PET fiber (3 and 15 deniers) in order to optimize the characteristic of sound absorption, and with various densities (895~1790 g/$cm^2$) by controlling the weight of PET of each layer. They were also compared with the commercial sound absorption materials made of glass wool. It was shown that the new PET had better absorption capability in both high and low frequency regions than that of the commercial material. It was revealed also that the density and the thickness of PET played an important role to determine the capability of sound absorption. The NRC (noise reduction coefficient) was increased by 22-39% with optimized PET sound absorption material. It should be noted that the PET can substitute the glass wool, a commercial sound absorption material, in view of environment and as well as recycle capability of sound absorption.

  • PDF

A Study on Extraction Condition of Co-PET from PET/Co-PET Sea-Island Type Microfiber Fabric (PET/Co-PET해도사 직물의 Co-PET추출 조건에 관한 연구)

  • 박명수;윤종호;조대현
    • Textile Coloration and Finishing
    • /
    • v.13 no.2
    • /
    • pp.120-127
    • /
    • 2001
  • In order to make a microfiber fabric with PET/Co-PET Sea-Island Type microfiber, the optimum condition of extraction and elimination of Co-PET from the mocrofiber was examined. At the same time, the physical property change of the fabric with respect to the change of the relative amount of the Co-PET in the microfiber was also examined to provide a directly applicable data set to the industry. The sample fabric used was warp 75/36(DTY) and weft 0.05d(PET/Co-PET, Sea Island Type Microfiber) twill fabric of 36 separated yarns+40/24(high shrinking yarn) with 130/48 ITY. The data set was made at various NaOH concentrations and steam temperatures with time as a main variable. The physical properties examined were the tensile properties. The results obtained were the tensile. The results obtained were 1. For a proper extraction of Co-PET (13.5%)from the microfiber with wet curing, it takes more than 5 min. in 8 and 12% of NaOH solutions but it takes only 3 min. in 18% of NaOH solution at 12$0^{\circ}C$. 2. For a proper extraction of Co-PET (13.5%) from the microfiber with wet curing, ti takes 3~5min. in 12 and 14% of NaOH solution and it takes less than 3 min. in 18% of NaOH solution at $130^\circ{C}$. 3. The increasing ratio of WT increased with increasing NaOH concentrations and the equilibrium point reached was 3 min. at $120^\circ{C}$. 4. The WT increasing ratio was greater in 14 and 18% NaOH solutions than in 8 and 12% of NaOH solutions at $130^\circ{C}$5. The RT ratio changes at $120^\circ{C}$ in 8 and 12% of NaOH solutions were indifferent from that at $130^\circ{C}$ in 12% of NaOH solution. However, the RT was apparently decreased with increasing NaOH concentration.

  • PDF

Effect of Transesterification on the Physical Properties of Poly(butylene terephthalate)/Poly(ethylene terephthalate) Blends (상호에스테르 교환반응이 폴리(부틸렌 테레프탈레이트)/폴리(에틸렌 테레프탈레이트) 블렌드 물성에 미치는 영향)

  • Kim Hoy-Kap;Kim Jun-Kung;Lim Soon-Ho;Lee Kun-Wong;Park Min;Kang Ho-Jong
    • Polymer(Korea)
    • /
    • v.30 no.2
    • /
    • pp.118-123
    • /
    • 2006
  • The effect of transesterification on the rheological properties in the melt reactive blending of poly(butylene terephthalate)(PBT) with poly(ethylene terephthalate)(PET) has been studied. The melt viscosity depression in PBT was found in PBT/PET blends due to the intrinsic low melt viscosity of PET compared to PBT. In addition, the thermal degradation in the melt blending and transesterification between two polyesters were considered as other factors fer the lowering of the melt viscosity in the blends. In the PBT/PET blends, calcium stearate was less effective than in PBT as a lubricant, however it accelerated both the thermal degradation and transesterification during melt blending. As a result, further melt viscosity drop was obtained in the reactive melt blending of PBT/PET.

Usefulness of $^{11}C-Methyl-L-and$ D-Methionine PET in Gliomas : with Special Attention to Recurrence

  • Cho, Won-Sang;Kim, Chi-Heon;Kim, Jeong-Eun;Chung, June-Key;Paek, Sun-Ha;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.176-182
    • /
    • 2006
  • Objective : This study concernes the usefulness of $^{11}C-methyl-L-and$ D-methionine[Met]-positron emission tomography[PET] for glioma grading and detection of recurrence in gliomas, compared with fluorine-18, 2-fluoro-deoxyglucose[FDG]-PET. Methods : Eighty patients underwent Met-PET study for evaluation of glioma : 37 astrocytomas [WHO grade II, 3; III, 8; IV, 26]. 27 oligodendrogliomas [WHO grade II, 16; III, 11]. and 12 suspicious recurrent gliomas. All images were taken within 2 weeks before operation. For suspicious recurrent cases on magnetic resonance images, both FDG-PET and Met-PET were performed. Results : In astrocytoma, Mean maximum standard uptake value[SUV] of region of interest[ROI] was not different between WHO grades [p=0.108]. but ROI/normal contralateral tissue SUV [T/N] ratio was statistically different between WHO grades [p=0.002]. T/N ratio was more closely related to visual scale than maximum SUV of ROI [p<0.001 and p=0.107 respectively]. In oligodendroglioma, there was no statistical difference between WHO grades in view of maximum SUV and T/N ratio. For recurrent gliomas, sensitivity of FDG-PET and Met-PET was 25% and 100%, while specificity of FDG-PET and Met-PET were 100% and 80%, respectively. Conclusion : Met-PET might be an appropriate tool for tumor grading in astrocytoma and be more sensitive for detection of recurrence in gliomas than FDG-PET.

Structure Development of Uniaxially Drawn Poly(trimethylene terephthalate)/ Poly(ethylene terephthalnte) Blends (일축 연신에 의한 폴리(트리메틸렌 데레프탈레이트)/ 폴리(에틸렌 데레프탈레이트) 블렌드의 구조 변화)

  • 전병환;김환기;강호종
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.67-76
    • /
    • 2004
  • The effects of drawing temperature and draw down ratio on thermal properties, crystallinity and orientation of poly(trimethylene terephthalate)/poly(ethylene terephthalate) (PTT/PET) 100/0 ,90/10, and 80/20 blends have been investigated. The crystallinity and glass transition temperature increased while cold crystallization temperature and cold enthalpy decreased due to the development of orientation and stress induced crystallization by the cord drawing. Introducing PET to PTT decreased the crystallinity of PTT. However, it enhanced the orientation of PTT/PET blends drawn at below the glass transition temperature of PET. This lead to the increase of tensile modulus and tensile strength of PTT/PET blends. The shrinkage increased with increasing orientation, which might be minimized by the development of crystalline morphology of PTT in the course of cold drawing.