• Title/Summary/Keyword: personal monitoring

Search Result 492, Processing Time 0.022 seconds

Workers' Exposure Characteristics to Noise in Car Inspection Processes (자동차검사 공정 근로자의 소음노출 특성)

  • Jang, Jae-Kil;Kim, Jong-Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.11
    • /
    • pp.854-860
    • /
    • 2014
  • Workers engaged in car inspection works have been exposed to many occupational hazards including noise, particulate matter, and volatile organic substances. Noise-induced hearing loss(NIHL) is one of the leading health hazards among Korean workers. The aim of this study is to evaluate the noise levels in several car inspection shops by introducing the evaluation methods of KMOEL/OSHA and ACGIH. Six sites in central area of Korea were selected to monitor the noise levels of workers by personal and area sampling methods for two consecutive days in spring, summer, fall and winter seasons. Dosimeters have been used for this noise monitoring program. Obtained noise levels by the evaluation method according to KMOEL/OSHA are the range of 50.2~88.2 dB(A), these are lower than KOEL/OSHA standards level of 90 dB(A). But highest noise by ACGIH's evaluation methodology is recorded 92.3 dB(A) and is greater than NIHL standard level of 85 dB(A). So that many workers may be exposed to the dangerous noise environment. The higher the car inspection loads daily, the higher the noise levels in the sites. Seasonal fluctuation of noise levels at the process might give monitoring results with high variations. Area noise levels showed higher than those of personal sampling, which illustrate some high noise spots in the car inspection areas.

Improving Personal Data Protection in IoT Environments (사물인터넷(IoT) 환경에서 개인정보보호 강화를 위한 제도 개선 방안)

  • Lee, Ae Ri;Son, Soomin;Kim, Hyun Jin;Kim, Beomsoo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.4
    • /
    • pp.995-1012
    • /
    • 2016
  • In Internet of Things (IoT) environments, devices or sensors everywhere can automatically collect data without the individual awareness, further combine and share data using ubiquitous network, and thus the development of IoT raises new challenges in respect of personal data protection and privacy. This study aims to identify main issues related to data protection in the IoT and propose adequate measures. We analyzed the types of personal data controllers and processors in IoT and figured out the issues regarding the processing of personal data and the rights to privacy of data subject. Accordingly, we suggested the institutional ways (e.g., establishment of user-friendly notice and flexible consent system, re-identification risk monitoring system, data protection in cross-border transfer, and user education) to improve the situation of personal data protection in IoT and finally proposed the improvement tasks to carry out first based on the degree of urgency and importance.

A Design and Implementation of Personal Vessel Monitoring System Based on Context Aware (상황인식 기반 개인 선박 상태감시시스템 설계 및 구현)

  • Shin, Do-Sung;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.112-118
    • /
    • 2011
  • Ship can be faced with more dangerous situations than ground vehicles due to the opened surroundings, sea. Therefore, it is very important to prevent the ship emergency by finding risk factor. In this paper, We propose context-aware monitoring system which that frequently check the condition of ship using the data that get through the installed sensor in the ship as gyro-sensor, strain-gage sensor. We analyzed sensor data through backpropagation algorithm and the Condition and Safety Information of sailing ship is transmitted to the crew's personal mobile device in the ship. Thus, moving crew can check the ship's condition in real time. As a result, we obtained about 95% accuracy for fire risk context and about 89% accuracy for body of Ship risk context in the simulated experiments.

Study on a Model-based Design Technique for Monitoring and Control of a Vehicle Cluster (자동차 클러스터의 감시 및 제어를 위한 모델기반설계 기법 연구)

  • Kim, Dong Hun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.27 no.1
    • /
    • pp.35-41
    • /
    • 2017
  • This paper presents the development of a monitoring and control system for a vehicle cluster using a model-based design technique. For MBD(model-based design), MATLAB GUI(Graphic User Interface), M programs, simulink, state flow, and tool boxes are used to monitor a number of data such as warning, interrupts, and etc. connected to a real vehicle cluster. As a monitoring tool, a PC(Personal Computer) station interworks with the real vehicle cluster through the interface commands of tool boxes. Thus, unlike existing text-based designs, the MBD based vehicle cluster system provides very easy algorithm updates and addition, since it offers a number of blocks and state flow programs for each functional actions. Furthermore, the proposed MBD technique reduces the required time and cost for the development and modification of a vehicle cluster, because of verification and validation of the cluster algorithm on the monitor through a PC.

Intercomparison Exercise at Harshaw 6600, DVG-02TM, and D-Shuttle Dosimeters for the Individual Monitoring of Ionizing Radiation

  • Kim, Dmitriy Spartakovich;Murayama, Kentaro;Nurtazin, Yernat;Koguchi, Yasuhiro;Kenzhin, Yergazy;Kawamura, Hiroshi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.79-88
    • /
    • 2019
  • Background: The main goal of experiments is to compare various operational and technical characteristics of D-Shuttle semiconductor personal dosimeters of the Japanese company "Chiyoda Technol Corporation" and Harshaw thermoluminescent dosimeters (TLD) manufactured by "Thermo Fisher Scientific" and DTL-02 of the Russian Research and Production Enterprise (RPE) "Doza" by their occupational and calibration exposure at various dose equivalents from 0.5 to 20 mSv of gamma-radiation. Materials and Methods: Besides dosimeters DTL-02, D-Shuttle and Harshaw TLD, there were also used: (1) the primary reference radionuclide source Hopewell Designs IAEA: G10-1-12 with $^{137}Cs$ isotope (an error is not more than 6% and activity is 20 Ci), and (2) the verification device UPGD-2M of RPE "Doza" and installed in the National Center for Expertise and Certification of the Republic of Kazakhstan (Kapchagai, the National Center for Expertise and Certification). Results and Discussion: The main results of researches are the following: (1) TLDs for Harshaw 6600 and DVG-02TM have an approximately equal measurement accuracy of the individual dose equivalents in the range from 0.5 to 20 mSv of gamma-radiation. (2) Advantages of dosimeters for Harshaw 6600 are due to the high measurement productivity and opportunity to indicate the dose on the skin $H_p$(0.07). Advantages of DVG-02TM consist of operation simplicity and lower cost than of Harshaw 6600. (3) D-Shuttles are convenient for use in the current and the operational monitoring of ionizing radiation. Measurement accuracy and 10% linearity of measurements are ensured when D-Shuttle is irradiated with dose equivalents below 1 mSv at the equivalent dose rate not higher than $3mSv{\cdot}hr^{-1}$. This allows using D-Shuttle at a routine technological activity. Conclusion: The obtained results of experiments demonstrate advantages and disadvantages of D-Shuttle semiconductor dosimeters in comparison with two TLD systems of DVG-02TM and Harshaw 6600.

The Purchasing Behavior and Use of Cosmetics Associated with Self-Monitoring and Demographic Variables (자기모니터링, 인구통계학적 변인과 화장품 구매행동 및 사용에 관한 연구)

  • 이명희
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.771-784
    • /
    • 2000
  • The purpose of this study was to investigate the casual relationships of self-monitoring, face satisfaction, and demographic variables on the purchasing behavior and use of cosmetics of women. Samples wre 479 women in their 20's to 50's in Seoul, Korea. Three factors of the purchase criteria of cosmetics derived by factor analysis : F.1 'intrinsic trait', F.2 'sales promotion and fashion', F.3 'economy. Women high in self-monitor purchased and used cosmetics more than those low in self-monitor. There were significant relationships between the purchasing behavior and use of cosmetics and age, education, and social stratification. Women in their 20's and 30's perceived purchase criteria associated with intrinsic trait such as color and becomingness as more important, 20's sales promotion and fashion, women with less education perceived economy more than did the others. Upper class women showed more concern for intrinsic trait such as quality and color of cosmetics than did lower class. Social stratification, age, self-monitoring, and education had a direct effect on the degree of cosmetics purchase. Self-monitoring and education had a direct effect on the degree of cosmetics use. Age, education, social stratification, and face satisfaction had an indirect effect on the degree of cosmetics purchase and use. The causal relationship of self-monitoring on the use of coloring cosmetics was stronger than the connection between self-monitoring and total cosmetics. The present findings provide that personal trait associated with self-monitoring of women is important variable in understanding of the purchasing behavior and use of cosmetics.

  • PDF

A Correlation Study of Surveillance Data and ATP Bioluminescence Assay for Verification of Hygienic Status in Major Hotels in Seoul (서울 시내 주요 호텔의 위생실태 조사와 ATP 결과의 상관 분석 연구)

  • Kim, Bo-Yeon;Song, Ha-Young;Park, In-Sook;Kim, Yong-Su;Lee, Yu-Si;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.3
    • /
    • pp.277-284
    • /
    • 2009
  • Currently food-borne disease is being increased at outdoor food services including hotels and restaurants. Speedy and convenient practical monitoring techniques to determine hygienic conditions are needed. This study was designed to verify correlation of direct ATP (Adenosine Tri-Phosphate) examination method using ATP bioluminescence and surveillance with check-list by inspector. Hygienic status of personal hygiene (hands), kitchen utensils (knives, chopping boards, kitchen towels, cap openers, food storage containers, and blade of slice machines), facilities and equipments (refrigerator handles, worktables, and sinks) in five major hotels in Seoul were examined. The result of personal hygiene of hotels was relatively better than other inspection items (46.6 points in personal hygiene, 40.2 points in kitchen utensils, 40.3 points in facilities & equipments). In ATP inspection, kitchen utensils and facilities & equipments were relatively clean comparing with personal hands data ($40.8{\pm}6.77\;RLU/cm^2$). After correlation analysis of surveillance in hygienic status points and ATP value, all results showed negative and high correlation. The surveillance data and ATP results investigating personal hygiene, kitchen utensils and facilities & equipments were highly correlated. The ATP examination method which shows real-time identification could be considered as an appropriate method to alternate current check-list dependent safety management in food services including hotels.

Development of Portable u-Health Monitoring System (휴대형 u-Health 모니터링 시스템 개발)

  • Han, Jung-Soo;Kim, Gui-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.46-53
    • /
    • 2009
  • This study aims to develop a mobile-based portable u-Health Monitoring System which provides a personal medical service on demand by processing patients' data intellectually achieved through sensing technique of non-restriction/non-consciousness oriented and deciding. To do this, we composed a USN-based portable monitoring unit. It is the one, that contains a somatometry sensor which is attached to patient's body and detects bio information, a portable wireless terminal which receives information from the sensor and transmits it to monitor server, and a monitor server which interprets received data through wireless network and processes. Also, it tries to develop a non-restriction /non-consciousness oriented sensing technique which is related to glycosuria and cardiovascular diseases.

Zigbee based 1-ch ECG device with activity monitoring function (지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발)

  • Hong, Joo-Hyun;Kim, Nam-Jin;Cha, Eun-Jong;Lee, Tae-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

Power supply system of the telecommunication equipment with monitoring function (모니터 기능을 갖는 통신기기용 전원 시스템)

  • Lee, Jung-Kee;Kim, Young-Tae;Kim, Chang-Sun;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF