• Title/Summary/Keyword: personal computer

Search Result 2,604, Processing Time 0.03 seconds

RMCS Plan and the Embodiment for the Home Network Service which is Safeent (안전한 Home Network 서비스를 위한 RMCS 설계 및 구현)

  • Sun, Jae-Hoon;Lee, Dong-Hwi;J. Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.5 no.2
    • /
    • pp.19-27
    • /
    • 2005
  • As home network is increasing to use, home network industry is developing too. Also, it is to be a popular subject in the network's topics. In this reasons, home network become a important thing because home gateway function is working between access network and home network. In the home network, it relates on the personal computer, home pad, and digital television. But, home gateway is not prepared standard point about techniques. Therefore, many kind of technique want to try for developing of home gateway's functions. Usually, we use ID/PASSWORD method in network control system. But, we found a lot of problems about classical network system while we experienced Jan/25 big trouble. We are considering about that home network system are using same network net. Therefore, seriously we have to check about security and safety at the home network's environment. This report focus on the home network's environment to control for using and efficiency and then it wants to find ways to protect from the internal and external attacks. Existing ID/PASSWORD method it used a electronic signature and the security against the approach from of external watch, the MIB structure of role base and the security of the Home network which leads the authority control which is safe even from the Home network inside it strengthened it used compared to it proposed.

  • PDF

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Design and construction method of an employment support management system for college students - A case study (대학생들을 위한 취업지원관리시스템의 설계 및 구축안-사례 연구)

  • Kim, Jae-Saeng;Kim, Kyung-Hun;Kyung, Tae-Won
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.329-338
    • /
    • 2014
  • Today, one of the important factors that determine the university rating is the employment rate. The jobseekers are using online or offline recruiting services in order to get the desired job information. There are lots of employment supporting systems as like web-based employment agencies and University's job centers, but they are focusing more on providing job information rather than on managing the employment support. In addition, those are insufficient to support business process associated with MOU companies, industry field training, mentoring processors, etc., and to continue to manage and to update the information (resume, personal statement, etc.) about the students which the companies want, and the information about the companies which jobseekers want. Therefore, it is required that the employment supporting system which not only storages the initial data (student and corporate information), but also assist the career placement. In this paper, we considered the specific employment rights management features of the existing employment support system, it could receive real-time job information in the smart phone, we presented the design and construction of the system linked to the Bachelor Information System.

Analysis of the Yearbook from the Korea Meteorological Administration using a text-mining agorithm (텍스트 마이닝 알고리즘을 이용한 기상청 기상연감 자료 분석)

  • Sun, Hyunseok;Lim, Changwon;Lee, YungSeop
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.4
    • /
    • pp.603-613
    • /
    • 2017
  • Many people have recently posted about personal interests on social media. The development of the Internet and computer technology has enabled the storage of digital forms of documents that has resulted in an explosion of the amount of textual data generated; subsequently there is an increased demand for technology to create valuable information from a large number of documents. A text mining technique is often used since text-based data is mostly composed of unstructured forms that are not suitable for the application of statistical analysis or data mining techniques. This study analyzed the Meteorological Yearbook data of the Korea Meteorological Administration (KMA) with a text mining technique. First, a term dictionary was constructed through preprocessing and a term-document matrix was generated. This term dictionary was then used to calculate the annual frequency of term, and observe the change in relative frequency for frequently appearing words. We also used regression analysis to identify terms with increasing and decreasing trends. We analyzed the trends in the Meteorological Yearbook of the KMA and analyzed trends of weather related news, weather status, and status of work trends that the KMA focused on. This study is to provide useful information that can help analyze and improve the meteorological services and reflect meteorological policy.

A study of statistical techniques for clinical data about cerebrovascular diseases (중풍임상자료(中風臨床資料)에 대한 통계적(統計的) 분석방법연구(分析方法硏究))

  • Kang, Hyo-Shin;Kwon, Young-Kyu;Park, Chang-Gook;Shin, Yang-Kyu;Kim, Sang-Chul
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.302-328
    • /
    • 1996
  • I . Objective and significance of the study To design a data acquisition chart, which facilitates data collection and analysis. The chart is also useful for solving problems that arise from personal variations in clinical symptoms and filling the knowledge base of an expert system. II. Content and scope 1. Collect the diagnosis knowledge of cerebrovacular diseases from doctors and analyze it. 2. Design a data acquisition chart. 3. Compare ODS and doctors with respect to their diagnosis results 4. Select patients who are determined to suffer from cerebrovascular diseases using CT(computed tomographic) scan, collect clinical data from them. III. Results and Application The chart be used for data collection and analysis in different medical hospitals, The results of data analysis facilitates collecting clinical data about other diseases and implementing the knowledge base. Also, the collected data serves as a tool for medical education, and cooperative diagnosis of oriental and western medical doctors.

  • PDF

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

- The Review of the Collar Consideration of G go-ri to Improve Drafting Method - (제도법 개선을 위한 저고리 깃 구성의 재고찰)

  • 정옥임
    • Journal of the Korean Home Economics Association
    • /
    • v.34 no.4
    • /
    • pp.249-263
    • /
    • 1996
  • According to the design method for constructing the G gori(the traditional Korean jacket)collar, there are differences in form after its completion. In the construction design of the midsection of the gusset as in that of the basic G gori, not only was the positioning of the two sides of the collar not smooth, but also, when the collar strip was attached, there would be an imbalance on one side or the other so that it was difficult to achieve symetry. Therefore in this project, by applying the pattern design of the gusset midsection to that of the collar midsection, not only did attaching the collar and the collar strip create a visual effect by equalizing the lengths of the tow sides, but the construction was also easy. This method of construction introduces the three-dimensional aspect of the human form in its conic, spherical and cylindrical aspects, so that, through schematizing the scientific character of Korea's clothing, its appropriateness is verified. As a matter of fact, since th-ere in no standardization of pattern whether for educational use or for mass-produced clothing, so that even the patterns used in computer-assisted design are executed according to the designer's personal skill, the reality is that after completion of construction the quality has not been uniform. For this schematization, inverse calculation of measurements pertaining to the calculation formula and of teaching materials has been referenced. In particular, the partial requlation of the calculation formula pertaining to the basic pattern construction, the method of making the collar midsection, and the construction method of the extreme and mean ratio adjustment can be adjusted for all measurements, thereby providing the establishment of a design criterion and the possibility of the standardization of construction methods. The production method for the pattern design is as follows: 1) The conic angle for the G gori's girth, length and neck width is fixed at 70 degrees. 2) The radius of the cone is B/2. 3) The calculation formula is B/4 + 1.5cm 4) The armhole formula is B/4, the same as in the basic method. 5) The width formula is B/10. 6) The ratio of the collar junction(width of collar + width of collar strip)to the gusset length is 5:8. 7) The length of the side seam is a length intersecting the armhole line and the conic radius (B/2), that is an arc that exceeds the length of the G gori's midsection; the component ratio of this length to the collar junction is accordingly 13:5. 8) The curve frame length of the back midsection is an arc exceeding B/4(the armhole line). 9) The ratio of the sleeve opening calculation formula to the armhole length is 8:5, forming an arc with the midsection length.

  • PDF

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.