• Title/Summary/Keyword: permeation rate

Search Result 316, Processing Time 0.036 seconds

Transdermal Permeation Behavior of 5-FU using Microneedle (마이크로니들을 이용한 5-FU의 경피투과 거동)

  • Kim, Myoung-Jin;Park, Jung-Soo;Kim, Yun-Tae;Lee, Jun-Hee;Ahn, Sik-Il;Park, Jong-Hak;Mo, Jong-Hyun;Lee, Tae-Wan;Lee, Han-Koo;Khang, Gil-Son;Lee, Hai-Bang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • 5-Fluorouracil (5-FU) is an antimetabolic of the pyrimidine derivatives that is used in chemotherapy for the treatment of several types of cancer. 5-FU have poor oral absorption and short biological half-time and strong side effects. Microneedle introduced to find a solution of problems. Microneedle device with roll was manufactured for transdermal delivery of various drugs. 5-FU was mixed in non-ionic surfactant such as tween 20 and tween 80. Camscope was used to analysis the permeation magnitude of treated skin by microneedle and trypan blue staining. The 5-FU solution with surfactant measured by ZETA-potential analysis system for stability of solution. The skin permeation rate of 5-FU determined by HPLC. We confirmed that cross treated skin was dyed more deeply than parallel treated skin through trypan blue staining. The results indicate that skin permeation rate of 5-FU was increased with the treatment types and treatment times.

Improvement in the Negative Bias Stability on the Water Vapor Permeation Barriers on ZnO-based Thin Film Transistors

  • Han, Dong-Seok;Sin, Sae-Yeong;Kim, Ung-Seon;Park, Jae-Hyeong;Park, Jong-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.450-450
    • /
    • 2012
  • In recent days, advances in ZnO-based oxide semiconductor materials have accelerated the development of thin-film transistors (TFTs), which are the building blocks for active matrix flat-panel displays including liquid crystal displays (LCD) and organic light-emitting diodes (OLED). In particular, the development of high-mobility ZnO-based channel materials has been proven invaluable; thus, there have been many reports of high-performance TFTs with oxide semiconductor channels such as ZnO, InZnO (IZO), ZnSnO (ZTO), and InGaZnO (IGZO). The reliability of oxide TFTs can be improved by examining more stable oxide channel materials. In the present study, we investigated the effects of an ALD-deposited water vapor permeation barrier on the stability of ZnO and HfZnO (HZO) thin film transistors. The device without the water vapor barrier films showed a large turn-on voltage shift under negative bias temperature stress. On the other hand, the suitably protected device with the lowest water vapor transmission rate showed a dramatically improved device performance. As the value of the water vapor transmission rate of the barrier films was decreased, the turn-on voltage instability reduced. The results suggest that water vapor related traps are strongly related to the instability of ZnO and HfZnO TFTs and that a proper combination of water vapor permeation barriers plays an important role in suppressing the device instability.

  • PDF

Rejection Characteristics of Various Heavy Metals by Low-pressure Nanofiltration (저압나노여과에 의한 각종 중금속의 제거 특성)

  • Oh, Jeong-Ik;Kim, Han-Seung;Kim, Chung-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.493-499
    • /
    • 2004
  • Rejection characteristics of heavy metals by nanofiltration membranes were investigated. Nanofiltration membranes rejected heavy metals much better than chloride, sulfate and TOC, of which concentration in synthetic wastewater was higher than that of heavy metals. To consider rejection characteristics of various metals by nanofiltration membranes, separation coefficient, which is the ratio of the metal permeation rate to the chloride ion or TOC permeation rate, was introduced. In spite of different materials and different nominal salt rejection of nanofiltration membrane used, the separation coefficients of metals were nearly the same. In particular, the separation coefficient of arsenic against chloride ion and TOC was larger than any other separation coefficient of heavy metals. These phenomena were observed in the relationship between the molar conductivity and the separation coefficient for heavy metals.

Penetration Enhancement of β2-Selective Agonist, Tulobuterol, Across Hairless Mouse Skin

  • Kim, Byung-Do;Choi, Hoo-Kyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2003
  • The effects of various pressure sensitive adhesives (PSA) and enhancers on the percutaneous absorption of tulobuterol were investigated. The permeation rate of tulobuterol through hairless mouse skin from various adhesives was evaluated using a flow-through diffusion cell system at $37^{\circ}C$. The permeability of tulobuterol was variable depending on the physicochemical property of the PSA. The permeation rate of tulobuterol from polyethylene oxide grafted acrylic adhesive matrix was higher than that from other PSA matrices. The flux of tulobuterol was $4.37{\pm}0.34\;{\mu}g/hr/cm^2$ from polyethylene oxide grafted acrylic adhesive matrix. When the effects of various enhancers on the percutaneous absorption of tulobuterol from grafted acrylic adhesive were evaluated, Plurol $oleique^{\circledR}$ showed higher flux than all other enhancers tested.

Clogging theory-based real time grouting management system applicable in soil conditions

  • Kwon, Young-Sam;Kim, Jinchun;Lee, In-Mo
    • Geomechanics and Engineering
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2018
  • In this study, a real-time grouting management system based on the clogging theory was established to manage injection procedure in real time. This system is capable of estimating hydraulic permeability with the passage of time as the grout permeates through the ground, and therefore, capable of estimating real time injection distance and flow rate. By adopting the Controlled Injection Pressure (CoIP) model, it was feasible to predict the grout permeation status with the elapse of time by consecutively updating the hydraulic gradient and flow rate estimated from a clogging-induced alteration of pore volume. Moreover, a method to estimate the volume of the fractured gap according to the reduction in injection pressure was proposed. The validity of the proposed system was successfully established by comparing the estimated values with the measured field data.

A Development on Assessment Method of PVC Gloves Used in Pest Control Program (해충제어프로그램에서 사용되는 PVC장갑의 평가방법 개발)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.53-58
    • /
    • 2006
  • Following a Mediterranean fruit fly outbreak in South Australia, a bait spray program involving the pesticides like malathion(MAL) was carried out. During the application, dermal exposure was considered for the pest controllers wearing PVC gloves. However there is a lack of information about PVC glove performance like break through times and permeation rates with MAL, therefore, a new analytical method for HPLC-UV was developed. A standard permeation test cell was used in this study. From the results of this study, more than 96% solubility of MAL was provided at 30% isopropyl alcohol in distilled water as a collecting media. However, there was significant decomposition of MAL when the solutions were kept at over $50^{\circ}C$ for 2-3 hours. As a mobile phase, 50% acetonitrile water solution (pH 6.0) gave the greater sensitivity compared with other compositions of acetonitrile solution. The arm section of the gloves had shorter breakthrough times and higher permeation rates compared with the palm. There was no malathion solution breakthrough up to 24 hours using the 1% MAL working strength solution. When the temperature was changed from $22{\pm}1^{\circ}C\;to\;37{\pm}1^{\circ}C$, the breakthrough times were decreased by 14.5% on palm and 37.5% on arm, and permeation rates were increased significantly. The findings of this study indicate that further investigations on used gloves, periods of use and varying working conditions like tasks and seasons should be carried out to assess potential worst case scenarios.

A Permeation Behavior for the Pervaporation of Aqueous Ethanol Solution (에탄올 수용액의 Pervaporation에서의 투과거동)

  • Bae, Seong-Youl;Lee, Han-Sun;Hwang, Seong-Min;Kim, Hee-Taik;Kumazawa, Hidehiro
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.127-138
    • /
    • 1994
  • In the process of pervaporation separation for aqueous ethanol solution through cellulose tai-acetate(CTA) membrane, the modelling on the solution-diffusion permeation mechanism was built up on the basis of sorption and permeation experimental results. Also its function type and parameter were examined. The composition of sorption equilibrium in three component system(Ethanol/Water/CTA) were compared with the calculated value by Flory-Huggins' equation using the pure component sorption data. In order to apply the thermodynamic equilibrium relationship between the membrane free composition in the membrane and the equilibrium composition in the liquid phase, the apparent activity this system, however, the results were not satisfied. Diffusion equations were expressed with the concentration gradient considering permeate alone, and a concentration-dependent diffusion coefficient which includes a parameter was used. And this model was fitted with the measured permeation rates. If the permeation rate and the amount of sorption of one component were much larger than those of the other, the bulk flow term could not be negligible. The flux and selectivity were increased with increasing temperature, and with decreasing downstream pressure.

  • PDF

Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -II. Permeation Characteristics of Tubular Membrane (Si 입자를 함유한 반도체 세정폐수의 한외여과 특성 [II] -Polyolefin 관형막에 의한 투과분리-)

  • 남석태;여호택;전재홍;이석기;최호상
    • Membrane Journal
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • Permeation behavior of the semiconductor rinsing wastewater contammg Si particles was examined by ultrafiltration using the polyolefin tubular membrane. Flux decline with time was due to the growth of Si cake deposited on the membrane surface and the pore plugging by Si particles. Cake filtration from the cross flow application is compared to the combination of pore blocking and cake filtration from the dead-end application. The cake resistance is 3.16 x $10^{12}$ -4.34 X $\times$$10^{12}$ $m^{-1}$ for the cross flow and 6.6 x $\times$$10^{12}$ -12.19 X $\times$$10^{12}$ $\times$$m^{-1}$for the dead-end flow, respectively. At the initial stage of operation, permeation flux of cross flow type was 1.7 time higher than that of the dead end flow type. Permeation flux of cross flow was about 42 e 1m2 hr and the rejection rate of Si particles was about 96 %. The average particle size of Si particle in the permeate was 20 nm.

  • PDF

Filtration-induced pressure evolution in permeation grouting

  • Zhou, Zilong;Zang, Haizhi;Wang, Shanyong;Cai, Xin;Du, Xueming
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.571-583
    • /
    • 2020
  • Permeation grouting is of great significance for consolidating geo-materials without disturbing the original geo-structure. To dip into the filtration-induced pressure increment that dominates the grout penetration in permeation grouting, nonlinear filtration coefficients embedded in a convection-filtration model were proposed, in which the volume of cement particles in grout and the deposited particles of skeleton were considered. An experiment was designed to determine the filtration coefficients and verify the model. The filtration coefficients deduced from experimental data were used in simulation, and the modelling results matched well with the experimental ones. The pressure drop revealed in experiments and captured in modelling demonstrated that the surge of inflow pressure lagged behind the stoppage of flow channels. In addition, both the consideration of the particles loss in liquid grout and the number of filtrated particles on pore walls presented an ideal trend in filtration rate, in which the filtration rate first rose rapidly and then reached to a steady plateau. Finally, this observed pressure drop was extended to the grouting design which alters the water to cement (W/C) ratio so as to alleviate the filtration effect. This study offers a novel insight into the filtration behaviour and has a practical meaning to extend penetration distance.

Percutaneous Absorption Characteristics of Antidepressant Paroxetine (항우울제인 Paroxetine의 피부 투과 특성 연구)

  • Jung, Duck-Chae;Hwang, Sung-Kwy;Oh, Se-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.170-177
    • /
    • 2011
  • Transdermal drug delivery(TDS) offers many important advantages. For instance, it is easy and painless, it protects the active compound from gastric enzymes, and it avoids the hepatic first-pass effect. Also, it is simple to terminate the therapy if any adverse or undesired effect occurs. But skin is a natural barrier, and only a few drugs can penetrate the skin easily and in sufficient quantities to be effective. Therefore, in recent years, numerous studies have been conducted in the area of penetration enhancement. The most commonly used transdermal system is the skin patch using various types of technologies. Compared with other method of dosage, it is possible to use for a long term. It is also possible to stop the drug dosage are stopped if the drug dosage lead to side effect. Polysaccharide, such as xanthan gum and algin were selected as base materials of TDS. Also, these polymers were characterized in terms of enhancers and drug contents. Among these polysaccharide, the permeation rate of Paroxetine such as lipophilic drug was the fastest in xanthan gum matrix in vitro. We used glycerin, PEG400 and PEG800 as enhancers. Since dermis has more water content(hydration) than the stratum corneum, skin permeation rate at steady state was highly influenced when PEG400 was more effective for lipophilic drug. Proper selection of the polymeric materials which resemble and enhance properties of the delivering drug was found to be important in controlling the skin permeation rate.