• Title/Summary/Keyword: peripheral blood flow

Search Result 208, Processing Time 0.029 seconds

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

도플러 초음파 기기를 이용한 편측 부전마비성 뇌졸중 환자와 정상인의 말초 혈류 비교 연구 (Comparison of Peripheral Blood Flow in Post-Stroke Hemiparetic Patients and Normal Person with Doppler Ultrasonography)

  • 한덕진;방창호;세르게이 김;배영민;신새론;양충용;이인
    • 동의생리병리학회지
    • /
    • 제23권6호
    • /
    • pp.1491-1496
    • /
    • 2009
  • Stroke is usually associated with the cerebral blood flow of the central nervous system. However, studies concerning the effects of neurologic sysmptoms induced from stroke on the peripheral blood flow has not taken place sufficiently. To ascertain the feasibility of a blood flow meter adopting to use doppler ultrasonogrphy, under the prospect that hemiparesis induced from stroke may have effect on the peripheral blood flow, the peripheral blood flow velocity was observed. The control group made up of healthy people without any factors capable of effecting the peripheral blood flow velocity, and patient group which consist of hemiparetic people induced from stroke, were recruited. Volumes of recruitment are 21 persons in the patient group, and 29 persons in the control group, but the final numbers of people are 17 and 21 respectively because of the inconsistancy in the method of the test. The non-invasive method of Doppler effect of Ultrasound was used to measure the blood flow velocity. The blood flow velocity in the peripheral part of left and right fourth fingers:dorsal branches of proper palmar digital artery to dorsum of distal phalanges, was measured in the control group and patient group through Doppler Ultrasound. In comparison of the control group and the patient group, the systolic blood flow velocity from the peripheral part of the upper extremity was lower in the patient group than that of the control group. According to such results, it is concluded that hemiparesis induces the reduction of the peripheral blood flow velocity in the systolic phase.

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향 (Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series)

  • 윤승규;이상훈;정우상;배영민
    • 대한한의학회지
    • /
    • 제31권4호
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.

간섭전류자극이 말초 혈류속도에 미치는 영향 (Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects)

  • 박장성;이재형
    • The Journal of Korean Physical Therapy
    • /
    • 제11권2호
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

  • PDF

Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察) (Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler)

  • 임종필;배나영;한경수;안택원
    • 혜화의학회지
    • /
    • 제15권2호
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

당뇨병환자와 정상인의 말초혈관혈류의 비선형적 운동계 분석에 대한 연구 (A Study of the Analysis of Characteristics of Nonlinear Dynamic System on Blood-Flow of Peripheral Blood-Vessel between Diabetic Patients and Control Subjects)

  • 김덕훈;최준영;이상훈;고한우;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.363-367
    • /
    • 1996
  • In general, the physiological systems have shown nonlinear complex phenomena. This study analyzes nonlinear characteristics of the flow of peripheral blood vessel dynamics in physiological systems using chaos theory. We performed this study by means of several quantity methods and power spectrum. The quantity methods are a phase space reconstruction and a poincare's map. And the power spectrum method is a conventional linear analysis. Experimental data have been acquired from examining 10 diabetic patients, and 10 control subjects in initial stable state. In acquisition experminetal data, we anlysized the differences of nonlinear characteristics between diabetic group and control group. The results of quality analysis methods showed the flow of peripheral blood vessel had the nonlinear and chaotic characteristics, screening a strange attractor on reconstructed phase space. In conclusion, the flow dynamics of peripheral blood vessel had a chaotic behavior of nonlinear dynamic systems, dynamic system, and differences of characteristic of nonlinear dynamic system.

  • PDF

Diffusion-Enhanced Modified Hemodialyzer

  • Lee, Kyung-Soo;Lee, Sa-Ram;Mun, Cho-Hae;Min, Byoung-Goo
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.455-460
    • /
    • 2007
  • Flow mismatch between blood and dialysate is invariably encountered during conventional hemodialysis, and this deteriorates diffusive mass transfer. A modification of a conventional dialyzer was conceived to prevent this mismatch. The modified dialyzer includes two independent blood flow regions (central and peripheral regions), which were achieved by redesigning the dialyzer cap. Resultantly, the blood stream was divided into two concentric dialyzer regions. Solutes clearances obtained using the modified dialyzers were compared with those of conventional dialyzers. Solutes clearances by conventional dialyzers were uniform, but solutes clearances by modified dialyzers were found to be dependent on the simulated blood split into dialyzer central and peripheral regions. Maximal clearances using the modified dialyzer were improved by up to approximately 7.6% for urea and 7.3% for creatinine, as compared with those of conventional dialyzers. More optimizations are required for clinical applications, but the finding that blood flowrates through central and peripheral fiber bundles can be easily regulated is encouraging.

토끼에 있어서 말초혈류운동의 비선형특성분석방법의 적합성에 관한 연구 (The Study of Compatibility for Method of Analysis of Nonlinear Characteristics of Blood Flow of Peripheral in Rabbit)

  • 남상희;최준영;이상훈
    • 한국의학물리학회지:의학물리
    • /
    • 제8권1호
    • /
    • pp.75-82
    • /
    • 1997
  • 인체의 생리기관의 운동은 매우 복잡하고 불규칙적인 운동을 보이고 있다. 특히 말초 혈관의 운동은 매우 민감하고 복잡한 운동특성을 보이고 있다. 그중에서도 당 (glucose)에 의한 운동은 매우 민감한 변화의 운동을 반응한다. 이런 운동을 분석하기에는 기존의 선형적인 분석방법으로 복잡한 혈류운동을 분석하고 예측하기에는 많은 문제점을 가지고 있다. 그래서 비선형적 운동계의 분석방법인 카오스이론의 시계열분석방법으로 분석하는 것이 적합하다. 이런 맥락으로 본 연구는 당의 주입에 의한 토끼의 말초혈류량의 스칼라적 데이터를 획득하여 시계열분석방법으로 다차원의 벡터로 재정의하여 말초혈관의 혈류운동이 카오스적 운동임을 재확인하고 비선형적분석방법의 적합성을 확인하고자 하였다. 그 결과 당 주입에 따른 혈당치의 변화에 따라 기존의 주파수분석 및 평균치분석에서 차이가 나타나지 않았지만 비선형적분석방법으로 분석한 결과 그 차이를 확인할수 있었고, 말초 혈류의운동이 카오스적현상을 보임을 확인하였다.

  • PDF

랫드의 간암 발생과정에서 분리한 자연살해세포의 활성측정 및 특성연구 (Study on natural killer cell activity and its characteristics during hepatocarcinogenesis in rats)

  • 정자영;이국경;길광섭;이영순
    • 대한수의학회지
    • /
    • 제39권1호
    • /
    • pp.169-176
    • /
    • 1999
  • The purposes of this study were to set up the method of the natural killer(NK) cell activity assay using the flow cytometer and to examine the characteristics and distribution of the NK cell during rat hepatocarcinogenesis. Forty five male 6 week-old specific pathogen free(SPF) Sprague-Dawley rats were randomly divided into three groups. Group I was the non-treated control and given normal diet and water. Group II was treated with diethylnitrosamine(DEN, 200mg/kg, i.p.) and partial hepatectomy. Group III was treated with DEN, partial hepatectomy and 0.05% phenobarbital sodium in water from 3 to 16 weeks. All animals were examined the morphology of the large granular lymphocyte(LGL), the LGL percent of the total lymphocytes and the LGL conjugation rate with YAC-1 cell in peripheral blood, spleen and liver. Moreover, activity of the LGL isolated from peripheral blood lymphocytes was determined using the flow cytometer. As results, LGL were observed in the peripheral blood, spleen and liver. LGL were observed the relatively faintly staining basophilic cytoplasm with granules, and eccentric, often kidney-shaped nuclei in Giemsa stain. Its size was $11{\sim}13{\mu}m$. LGL percentage of the isolated lymphocytes in peripheral blood, spleen and liver were 1.8~2.3%, 1.3~1.4% and 0.87~0.99%, respectively. LGL conjugation rate with YAC-1 cell was shown to be peripheral blood(9.3~10.3 %) > spleen(7.7~8.7%) > liver(5.6~7.0%). The activity of the LGL isolated from peripheral blood lymphocytes in Group I, II and III was 33.7%, 30.5% and 35.4%, respectively. However, all values were not significantly between groups.

  • PDF