Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor  

Ko, J.I. (Dept of Biomed. Eng., Graduate School, Yonsei Univ.)
Jeong, I.C. (Dept of Biomed. Eng., Graduate School, Yonsei Univ.)
Lee, D.H. (Dept of Biomed. Eng., Graduate School, Yonsei Univ.)
Park, S.W. (Dept of Biomed. Eng., Graduate School, Yonsei Univ.)
Hwang, S.O. (Dept of Emergency Med., College of Wonju Medicine, Yonsei Univ.)
Park, S.M. (Dept of Nursing, College of Wonju Medicine, Yonsei Univ.)
Kim, G.Y. (Dept of Nursing, College of Wonju Medicine, Yonsei Univ.)
Joo, H.S. (Dept of Nursing, College of Wonju Medicine, Yonsei Univ.)
Yoon, H.R. (Dept of Biomed. Eng., Graduate School, Yonsei Univ.)
Publication Information
Journal of Biomedical Engineering Research / v.28, no.2, 2007 , pp. 178-186 More about this Journal
Abstract
This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.
Keywords
Sphygmomanometers; optical sensor; BP compensation; PPG;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. Gregory Downs, Michael P. Burns, Andrew R. Nara, Blood Pressure(BioPhysical Measurement Series), SpaceLabs Inc
2 Meir Nitzan, Chaim Rosenfeld, A. Teddy Weiss, Ehud Grossman, Amikam Patron, and Alan Murray, 'Effects of external pressure on arteries distal to the cuff during sphygmomanometry,' IEEE Transactions on Biomedical Engineering, vol.52, no. 6, pp.1120-1127, JUNE 2005   DOI   ScienceOn
3 H. W. Lee, Estimation of non invasive blood pressure using peripheral plethysmography, Dept of Biomed. Eng., Graduate School, Yonsei Univ. ,2003
4 Amoore JN, Scott DHT., 'Can simulators evaluate systematic differences between oscillometric non-invasive blood pressure monitors,' BloodPress Monit, vol. 5, pp. 81-89, 2000
5 O'Brien E, Atkins N, Mee F, O'Malley K., 'Comparative accuracy of six ambulatory devices according to blood pressure levels,' J. Hypertens, vol.11, pp.673-675, 1993   DOI
6 American National Standard, ANSUAAMI SP10:2002 & ANSI/AAMI SP10:2002/A1:2003 P20-21
7 W. R. Lee, Clinical cardiology, Korea Medical Publishing company, 2002, pp.471
8 Baker DP, Westenskow DR, Kuck K, 'Theoretical analysis of non-invasive oscillometric amplitude algorithm for estimating mean blood pressure,' Med. Biol. Eng. Comput., vol. 35, pp. 271-278, 1997   DOI   ScienceOn
9 Robin P Smith, Jerome Argod, Jean-Louis Pepin, Patrick A Levy, 'Pulse transit time: an appraisal of potential clinical applications,' Thorax, vol.54, pp.452-457, 1999   DOI   PUBMED   ScienceOn