• Title/Summary/Keyword: per-cooling

Search Result 248, Processing Time 0.03 seconds

A Study on the Classification of 500m×500m Mesh Level by the Combinations of Building Needs in Busan for the Feasibility Evaluation of Ocean Energy Plant Introduction (해양에너지 활용지역 선정을 위한 부산시 500m 메시 레벨에서의 건물용도구성에 의한 유형화 연구)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.1
    • /
    • pp.57-62
    • /
    • 2011
  • On the view point of renewable energies as energy sources of district heating and cooling plant, the purpose of this study is to develop, classify and map the 500m${\times}$500m mesh, of which is treated as normal size in DHC regulations for evaluation process. Followings are the results. Various building and geographical informations including 13 districts and 108 counties are re-defined to create 500m${\times}$500m meshes, and it is find out that 3,289 meshes among 8,463 meshes have meaningful floor areas. Only 59 meshes(1.8%) are evaluated as mesh which has more than 50% of building volume ratio per mesh. 5 clusters classified by principal analysis and cluster analysis with building needs' characteristics are defined. Gwang-an Dong is representative of cluster 1 characterized as commercial area, and the cluster 4, 5 which has mainly residential needs are distributed in Yong-ho dong. Because there are a lot of cluster 3 meshes, which has complex needs area based on residential, cluster 3 could be defined as representative of Busan metropolitan city.

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

Typhoon Researches Using the Ieodo Ocean Research Station: Part I. Importance and Present Status of Typhoon Observation (이어도 종합해양과학기지를 활용한 태풍연구: Part I. 태풍관측의 중요성 및 현황)

  • Moon, Il-Ju;Shim, Jae-Seol;Lee, Dong Young;Lee, Jae Hak;Min, In-Ki;Lim, Kwan Chang
    • Atmosphere
    • /
    • v.20 no.3
    • /
    • pp.247-260
    • /
    • 2010
  • A recent dramatic increase of natural hazards in the Korean peninsular (KP) due to typhoons have raised necessities for the accurate typhoon prediction. Ieodo ocean research station (IORS) has been constructed in June 2003 at the open ocean where typhoons pass frequently, aiming to observe typhoons before the landfall to the KP and hence to improve the prediction skill. This paper investigates the importance of measurements at the IORS in the typhoon research and forecast. Analysis of the best track data in the N. W. Pacific shows that about one typhoon passes over the IORS per year on the average and 54% of the KP-landfall typhoons during 59 years (1950-2008) passed by the IORS within the range of the 150-km radius. The data observed during the event of typhoons reveals that the IORS can provide useful information for the typhoon prediction prior to the landfall (mainland: before 8-10 hrs, Jeju Island: before 4-6 hrs), which may contribute to improving the typhoon prediction skill and conducting the disaster prevention during the landfall. Since 2003, nine typhoons have influenced the IORS by strong winds above 17m/s. Among them, the typhoon Maemi (0314) was the strongest and brought the largest damages in Korea. The various oceanic and atmospheric observation data at the IORS suggest that the Maemi (0314) has kept the strong intensity until the landfall as passing over warm ocean currents, while the Ewiniar (0603) has weakened rapidly as passing over the Yellow Sea Bottom Cold Water (YSBCW), mainly due to the storm's self-induced surface cooling. It is revealed that the IORS is located in the best place for monitering the patterns of the warm currents and the YSBCW which varies in time and space.

Forged Product Characteristic and Cold Rolling Simulation for High-Nitrogen Stainless Steel (HNS) (TP304계 고질소 스테인레스강의 단조특성과 냉간압연 모사)

  • Lee, M.R.;Lee, J.W.;Kim, B.K.;Kim, Y.D.;Shin, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.310-313
    • /
    • 2009
  • Several high nitrogen stainless steel ingots(100kg) were fabricated with changing Ni and $[N]_2$ contents by Pressurized Vacuum Induction Melting(P_VIM). After free forging process, chemical compositions, microstructure and mechanical properties were estimated. Hardness was increased with the increase of $[N]_2$ content. Furthermore, microstructure including a lot of tempering twins was observed with optical microscope. Mechanical properties were estimated as function of solution treatment temperature and cooling method(air/water) under duration time of 1 hr on sample that were fabricated with Ni content under the atmospheric $[N]_2$ pressure. At solution treatment range of $1050{\sim}1100^{\circ}C$, hardness was decreased with the increase of solution temperature and there were little discrepancy of microstructure and hardness with cooling method. Computer simulation was carried out in order to inspect pass schedule in cold rolling process. When the condition of simulation was roll speed of 2.5mpm, rolling rate $15{\sim}17%$ per pass, it was ascertained that the formation such as deformation by sticking and lamellar sliver etc. was restricted from a simulation.

  • PDF

Analysis of Energy Consumption Pattern and Greenhouse Gas Emission in the Academic Facility (대학에서의 에너지 소비패턴 및 온실가스 배출현황 분석)

  • Kim, Jin-Sik;Lee, Kyoung-Bin;Lee, Im-Hack;Kim, Shin-Do
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.604-612
    • /
    • 2012
  • Self-management plan for GHG (Greenhouse Gas) reduction should be prepared in academic facilities, which occupy a large amount of energy consumption. In this study, a university was chosen as one of the major academic facilities and its energy consuming pattern and GHG emission were analyzed. The results have shown that annual $CO_2$ emission from university buildings was 10,452 ton-$CO_2$ (0.65 ton-$CO_2/m^2$), and dependent upon 78.0% electricity, 20.5% LNG and 1.5% oil, respectively as energy sources. According to more detail analysis by usage of energy consumption, appliances occupies 36.7% followed by gas heating (18.9%), lighting (18.6%), heating with electricity (12.5%), cooling with electricity (10.2%), transportation (1.5%), gas cooling (1.2%) and cooking (0.4%). Furthermore, annual $CO_2$ emissions per unit area and a student by electricity usage were evaluated to 51.30 kg-$CO_2/m^2$ and 981.86 kg-$CO_2$/capita, respectively and those by LNG usage were 14.61 kg-$CO_2/m^2$ and 241.01 kg-$CO_2$/capita.

Greenhouse Gas Mitigation Effect Analysis by Establishing Additional Heat Storage System for Combined Heat and Power Plant (열병합발전소에서의 축열조 증설에 의한 온실가스 감축 효과 분석)

  • Kim, Shang Mork;Yoon, Joong Hwan;Lim, Kyoung Mi
    • Journal of Climate Change Research
    • /
    • v.2 no.3
    • /
    • pp.175-189
    • /
    • 2011
  • In this research, we describe the methodology and the quantification about GHG reduction effects, expected by optimization of operation mode according to establishing additional heat storage system of Bundang Combined Cycle Power Plant. As an intermediate form of General Combined Cycle Power Plant and Heat supply only district heating plant, Bundang Combined Cycle Power Plant(and Ilsan, Anyang, Bucheon) is possible to satisfy demand for the electrical load and thermal load capacity at the same time through changes to the operation mode itself. Therefore, through the operating transition of high-efficiency mode that the condenser cooling water is recovered and supplied to district heat and cooling, establishing additional heat storage system have flexible supply ability at the power and heat market. In this research, We calculated using the operating performance for the last three years(2008~2010) and efficiency of each mode-specific values. As a result, GHG reduction effects were calculated as $97.95kg_{-}CO_2/Gcal$ per heat energy 1 Gcal supplied at the heat storage system and we expected emmision reduction effect about $13,500Ton_{-}CO_2/yr$.

Numerical analysis of heat dissipation performance of heat sink for IGBT module depending on serpentine channel shape (수치 해석을 통한 절연 게이트 양극성 트랜지스터 모듈의 히트 싱크 유로 형상에 따른 방열 성능 분석)

  • Son, Jonghyun;Park, Sungkeun;Kim, Young-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.415-421
    • /
    • 2021
  • This study analyzed the effect on the cooling performance of the channel shape of a heat sink for an insulated gate bipolar transistor (IGBT). A serpentine channel was used for this analysis, and the parameter for the analysis was the number of curves. The analysis was conducted using computational fluid dynamics with the commercial software ANSYS fluent. One curve in the channel improved the heat dissipation performance of the heat sink by up to 8% compared to a straight-channel heat sink. However, two curves in the channel could not improve the heat discharge performance further. Instead, the two curves caused a higher pressure drop, which induces parasitic loss for the pumping of coolant. The pressure drop of the two-curve channel case was 2.48-2.55 times larger than that of a one-curve channel. This higher pressure drop decreased the heat discharge efficiency of the heat sink with two curves. The discharge heat per unit pressure drop was calculated, and the result of the straight heat sink was highest among the analyzed cases. This means that the heat discharge efficiency of the straight heat sink is the highest.

Evaluation of Cavity Characterization Using Infrared Thermal Images (적외선 이미지를 이용한 지하공동 평가)

  • Jang, Byeong-Su;Kim, Young-Seok;Kim, Se-Won ;Choi, Hyun-Jun;Yoon, Hyung-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.7
    • /
    • pp.69-76
    • /
    • 2023
  • Cavity causes settlement and its remediation after an accident results in significant time and economic losses. This study aims to experimentally evaluate the prospect of using infrared camera to detect and measure underground subsidence. Emissivity is necessary to detect the energy emitted from an object and accurately assess temperature using an infrared camera. The emissivity in laboratory tests is fixed to evaluate a reasonable distance between the infrared camera and the object, and temperature values are assessed at various distances. In field experiments, the cavity of the field experiment is simulated using a PVC pipe with a diameter of 5 cm, artificially buried at depths of 5 and 25 cm from the surface. The infrared camera measurements are taken from 4 PM to 3 PM of the next day (a total of 23 h). The analysis included the time-series temperature distribution and the cooling rate index assessment, which represents the temperature change rate per unit of time. The results showed that various temperature trends are observed depending on the location of the subsidence. This study demonstrates that the infrared camera can be used to assess the condition of the subsurface.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

Transient Simulations of Concrete Ablation due to a Release of Molten Core Material (방출된 노심용융 물질에 의한 콘크리트 침식 천이 모의)

  • Kim, H.Y.;Park, J.H.;Kim, H.D.;Kim, S.W.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3491-3496
    • /
    • 2007
  • If a molten core is released from a reactor vessel into a reactor cavity during a severe accident, an important safety issue of coolability of the molten core from top-flooding and concrete ablation due to a molten core concrete interaction (MCCI) is still unresolved. The released molten core debris would attack the concrete wall and basemat of the reactor cavity, which will lead to inevitable concrete decompositions and possible radiological releases. In a OECD/MCCI project scheduled for 4 years from 2002. 1 to 2005. 12, a series of tests were performed to secure the data for cooling the molten core spread out at the reactor cavity and for the 2-D long-term core concrete interaction (CCI). The tests included not only separate effect tests such as a melt eruption, water ingression, and crust failure tests with a prototypic material but also 2-D CCI tests with a prototypic material under dry and flooded cavity conditions. The paper deals with the transient simulations on the CCI-2 test by using a severe accident analysis code, CORQUENCH, which was developed at Argonne National Laboratory (ANL). Similar simulations had been already per for me d by using MELCOR 1.8.5 code. Unlike the MELCOR 1.8.5, the CORQUENCH includes a melt eruption mode I and a newly developed water ingression model based on the water ingression tests under the OECD/MCCI project. In order to adjust the geometrical differences between the CCI-2 test (rectangular geometry) and the simulations (cylindrical geometry), the same scaling methodology as used in the MELCOR simulation was applied. For the direct comparison of the simulation results, the same inputs for the MELCOR simulation were used. The simulation results were compared with the previous results by using MELCOR 1.8.5.

  • PDF