• Title/Summary/Keyword: pedicle

Search Result 498, Processing Time 0.029 seconds

Ipsilateral Dorsalis Pedis Vascularized Pedicle Flap in the Distal Leg and Foot

  • Yu, Chang Eun;Lee, Jun-Mo;Choi, Hee-Rack
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.2
    • /
    • pp.52-56
    • /
    • 2013
  • Purpose: We had proceeded seven iIpsilateral dorsalis pedis vascularized pedicle flaps in the distal leg and foot to cover the restricted size defects and followed-up average for 5 years and 9 months to evaluate the survival rate, neurosensory function and cosmesis in final results. Materials and Methods: From January 1999 through October 2012, we have performed iIpsilateral dorsalis pedis vascularized pedicle flaps in the distal leg and foot to cover the restricted size defect (average around $3.6{\times}2.4cm$) in 7 cases and average age was 41.6 years (21.5 to 59.0 years). Lesion site was posterior heel in 4 cases, distal anterior leg in 3 cases. Donor structure was the dorsalis pedis artery and the first dorsal metatarsal vessel and deep peroneal nerve in 3 cases and the dorsalis pedis artery and the first dorsal metatarsal vessel in 4 cases. Results: Seven cases (100%) were survived and defect area was healed with continuous dressing without skin graft. The sensory function in the neurovascular flap was restored to normal in 3 cases. Cosmesis was good and fair in 7 cases (85.7%). Conclusion: Ipsilateral dorsalis pedis vascularized pedicle flap in the distal leg and foot is one of the choice to cover the exposed bone and soft tissues without microsurgical procedure.

  • PDF

A New Method of Approach for Percutaneous Thoracic Vertebroplasty in Vertebral Compression Fracture -Case report- (흉추 압박골절환자를 위한 경피적 척추성형술의 새로운 접근법 -증례 보고-)

  • Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.13 no.2
    • /
    • pp.237-241
    • /
    • 2000
  • Vertebral compression fractures commonly afflict the elderly. Some patients suffer from severe mechanical pain in spite of treatments with strong analgesics and bracing. Vertebroplasty, which was originally used for vertebral hemangioma, is effective for patients who do not respond to these more conservative treatments. However, the procedure has some risk. Leaks of bone cement into perineural tissues can be a serious complication. In contrast to the lumbar vertebrae, the outer margin of the pedicle of the thoracic vertebrae is almost in line with the outer margin of the body. This, combined with the thinner pedicle of the thoracic vertebrae, makes proper needle placement difficult. The posterolateral approach is preferred to the transpedicular approach in order to avoid the danger of destroying the inner cortex of the pedicle. But there can be a problems with the standard posterolateral approach. The rib can be broken, the pleura can be punctured. A new and safer approach is possible. Before penetrating the bone, the needle is positioned at the upper margin of the transverse process, 5 mm away from the pedicle. To achieve this positioning, the needle must puncture the skin 1~1.5 cm laterally and 3~5 mm cranially to the target point on the bone. This approach was used for 10 patients and we achieved good results with no serious complication.

  • PDF

Prediction of Mechanical Behaviors of Bio-mechanical Materials (생체공학용 척추경 나사의 기계적 거동 예측)

  • Park, Joon-Sik;Choi, Jin Hwa;Cho, Myeong-Woo;Choi, Gil-Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.72-78
    • /
    • 2004
  • In this paper, mechanical behaviors of developed pedicle screw system, made of bio-mechanical materials(Ti-6Al-4V, Grade 5), ale predicted using FEM analysis. As a first step, morphologic construction of normal Korean spines and surgical operation convenience are considered to design optimum pedicle screw system. In this step, various design variables are considered as design parameters to develop optimized models. As a next step, tension and bending tests are performed to improve the structural performance of the developed system using finite element method. In this step, required Static compression and bending test specifications by ASTM F-04 25 04 01 are applied to understand the bio-mechanical behaviors of the designed spinal implant system under various load types. As the results of this research, it is possible to develop efficient pedicle screw system, having enough rigidity and fixation to stand any spinal damage under allowable stress conditions.

  • PDF

Recycling of flap pedicle in complex lower extremity reconstruction: A proof of free muscle flap neovascularization

  • Pafitanis, Georgios;Vris, Alexandros;Reissis, Dimitris;Sadri, Amir;Alamouti, Reza;Myers, Simon;Sadigh, Parviz
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.619-621
    • /
    • 2020
  • This article portrays the authors' clinical experience of a complex case of lower extremity reconstruction using a recycled pedicle from 10 years old free latissimus dorsi musculocutaneous flap to supply a new free anterolateral thigh flap for proximal tibia wound defect reconstruction. It provides clinical evidence that muscle neovascularization occurs and supports the dogma peripheral tissue neovascularization. This case stipulates that recycling of pedicle is feasible, when used with appropriate strategy and safety and also provides evidence for the long-term survival of greater saphenous vein grafts in lower extremity reconstruction.

Salvage of late flap compromise in deep inferior epigastric perforator flaps: To revise or not to revise

  • Hong, Seung Heon;Lee, Kyeong-Tae;Pyon, Jai-Kyong
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.97-101
    • /
    • 2020
  • Although the success rate of deep inferior epigastric perforator (DIEP) flaps has increased, late flap failures still occur and have a low salvage rate. The present article describes a case of salvage of a case of late flap failure using the pedicle vein as a vein graft source. A 50-yearold woman underwent a bilateral DIEP free flap procedure. On postoperative day 6, she experienced flap compromise and underwent emergency flap revision. In the flap revision, flap venous drainage and the superficial inferior epigastric vein were completely obstructed. A Fogarty catheter was used to remove a thrombus from the completely obstructed pedicle vein, and this pedicle vein was used as a graft source and was ligated in retrograde fashion to the flap vein stump. After injection of urokinase into the arterial branch, venous flow to the flap was restored. At a 6-month follow-up visit in the outpatient clinic, only partial fat necrosis at the flap was noted. By dissecting various perforators in the initial operation, decisions regarding immediate revision can be made with more confidence. Additionally, the combined procedures performed in this case may be helpful even for practitioners treating cases of late flap compromise.

The Use of Arteriovenous Bundle Interposition Grafts in Microsurgical Reconstruction: A Systematic Review of the Literature

  • Kareh, Aurora M.;Tadisina, Kashyap Komarraju;Chun, Magnus;Kaswan, Sumesh;Xu, Kyle Y.
    • Archives of Plastic Surgery
    • /
    • v.49 no.4
    • /
    • pp.543-548
    • /
    • 2022
  • Microvascular reconstruction frequently requires anastomosis outside of the zone of injury for successful reconstruction. Multiple options exist for pedicle lengthening including vein grafts, arteriovenous loops, and arteriovenous bundle interposition grafts. The authors performed a systematic review of arteriovenous bundle interposition grafts to elucidate indications and outcomes of arteriovenous grafts in microvascular reconstruction. A systematic review of the literature was performed using targeted keywords. Data extraction was performed by two independent authors, and descriptive statistics were used to analyze pooled data. Forty-four patients underwent pedicle lengthening with an arteriovenous graft from the descending branch of the lateral circumflex femoral artery. Most common indications for flap reconstruction were malignancy (n = 12), trauma (n = 7), and diabetic ulceration (n = 4). The most commonly used free flap was the anterolateral thigh flap (n = 18). There were five complications, with one resulting in flap loss. Arteriovenous bundle interposition grafts are a viable option for pedicle lengthening when free flap distant anastomosis is required. The descending branch of the lateral circumflex femoral artery may be used for a variety of defects and can be used in conjunction with fasciocutaneous, osteocutaneous, muscle, and chimeric free flaps.

Initial report of extraperitoneal pedicle dissection in deep inferior epigastric perforator flap breast reconstruction using the da Vinci SP

  • Jung, Ji Hyuk;Jeon, Yeo Reum;Lee, Dong Won;Park, Hyung Seok;Lew, Dae Hyun;Roh, Tae Suk;Song, Seung Yong
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.34-38
    • /
    • 2022
  • The deep inferior epigastric perforator (DIEP) flap has been widely used for autologous breast reconstruction after mastectomy. In the conventional surgical method, a long incision is needed at the anterior fascia of the rectus abdominis muscle to obtain sufficient pedicle length; this may increase the risk of incisional hernia. To shorten the incision, several trials have investigated the use of endoscopic/robotic devices for pedicle harvest; however, making multiple additional incisions for port insertion and operating in the intraperitoneal field were inevitable. Here, we describe the first case, in which a DIEP free flap was successfully made using the da Vinci SP model. Our findings can help surgeons perform operations in smaller fields with a single port in the extraperitoneal space. Moreover, this method is expected to lead to fewer donor-related complications and faster healing.

Extracorporeal Pedicles for Free Flap Reconstruction in Diabetic Lower Extremity Wounds

  • Alejandro R. Gimenez;Daniel Lazo;Salomao Chade;Alex Fioravanti;Olimpio Colicchio;Daniel Alvarez;Ernani Junior;Sarth Raj;Amjed Abu-Ghname;Marco Maricevich
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.782-784
    • /
    • 2022
  • Diabetic foot ulcers are a severe complication of diabetes, and their management requires a multidisciplinary approach for optimal management. When treating these ulcers, limb salvage remains the ultimate goal. In this article, we present the "hanging" free flap for the reconstruction of chronic lower extremity diabetic ulcers. This two-staged approach involves standard free flap harvest and inset; however, following inset the "hanging" pedicle is covered within a skin graft instead of making extraneous incisions within the undisturbed soft tissues or tunnels that can compress the vessels. After incorporation, a second-stage surgery is performed in 4 to 6 weeks which entails pedicle division, flap inset revision, and end-to-end reconstruction of the recipient vessel. Besides decreasing the number of incisions on diabetic patients, our novel technique utilizing the "hanging" pedicle simplifies flap monitoring and inset and allows reconstruction of recipient vessels to reestablish distal blood flow.

Comparison of Morphological Characteristics of the Subaxial Cervical Spine between Athetoid Cerebral Palsy and Normal Control

  • Kim, Jun Young;Kwon, Jae Yeol;Kim, Moon Seok;Lee, Jeong Jae;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.243-250
    • /
    • 2018
  • Objective : To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. Methods : We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. Results : LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. Conclusion : LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.