• Title/Summary/Keyword: peak value detector

Search Result 37, Processing Time 0.026 seconds

Comparison of Various Methods for Estrus Stage Determination in Bitch (개의 발정 진단 방법에 따른 효율 비교)

  • Ko, Young-Jin;Kang, Eun-Ju;Lee, Sung-Lim
    • Journal of Embryo Transfer
    • /
    • v.24 no.3
    • /
    • pp.131-137
    • /
    • 2009
  • In dogs, correct diagnosis of estrus is important and the exact time of ovulation can be determined by variouse methods. Vaginal cytology has commonly used in conjunction with the physical examination, clinical history, vaginoscopy, and hormonal assays to determine the stage of the reproductive cycle. This study was therefore investigated the effectiveness of direct ovulation detector designed by changes of electrical resistance in vaginal mucus following different estrus cycles with several methods; vaginal cytology, concentration of plasma estrogen and progesterone, and direct examination by laparotomy. A total of 12 bitches was selected for the study and observed estrus signs. The bitches were evaluated clinical sign (vulvar swelling and bleeding), cytological examination (keratocyte and RBC), electrical resistance, plasma estrogen and progesterone concentration for estrus assessment. Accuracy of ovulation detection by vaginal cytology was significantly (p<0.05) lower than those by electrical resistance and plasma progesterone concentration, based on the confirmation by laparotomy. Vaginal smear is not confidential method compared to detection of electrical resistance and plasma progesterone concentration at ovulation. Although the value of electrical resistance was varied at the same points of estrus in individuals, ovulation was occurred at the first day which shown the peak of electrical resistance and mating time was third day after peak. In conclusion, ovulation detector designed by changes of electrical resistance is an effective and economic instrument for predicting estrus and ovulation in bitches.

Growth of HgCdTe thin film by the hot-wall epitaxy method (Hot-wall epitaxy 방법에 의한 HgCdTe 박막 성장)

  • 최규상;정태수
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.406-410
    • /
    • 2000
  • Using the hot-wall epitaxy method, we grew a $Hg_{1-x}Cd_xTe$ (MCT) thin film in-situ after growing (111) CdTe of 9 $mu \textrm{m}$ as a buffer layer. The value of FWHM of double crystal x-ray diffraction rocking curve was 125 arcsec and the surface morphology was clean with a small roughness of 10 nm. From measuring the photocurrent of the grown MCT thin film, the maximum peak wavelength and the cut-off wavelength were 1.1050 $\mu\textrm{m}$ (1.1220 eV) and 1.2632 $\mu\textrm{m}$ (0.9815 eV), respectively. This peak wavelength corresponds to the peak of the band gap due to the intrinsic transition of the photoconductor. Therefore, the MCT thin film could be used as the photoconducting detector sensing a near-IR wavelength band from 1.0 to 1.6 $\mu\textrm{m}$.

  • PDF

Comparative Study of the Symbol Rate Detection of Unknown Digital Communication Signals (미상 디지털 통신 신호의 심볼율 검출 방식 비교)

  • Joo, Se-Joon;Hong, Een-Kee
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents and compares several techniques that detect the symbol rate of unknown received signal. Symbol rate is detected from the power spectral density of the circuits such as the delay and multiplier circuit, the square law circuit, and analytic signal, etc. As a result of discrete Fourier transform of the output signals of these circuits, a lot of spectral lines and some peaks appear in frequency domain and the position of first peak is corresponding to the symbol rate. If a spectral line on the frequency that is not located in symbol rate is larger than the first peak, the symbol rate is erroneously detected. Thus, the ratio between the value of first peak and the highest side spectral line is used for the measure of the performance of symbol rate detector. For the MPSK modulation, the analytic signal method shows better performance than the delay and multiplier and square law circuits when the received signal power is lager than -20dB. It is also noted that the delay and multiplier circuit is not able to detect the symbol rate for the QAM modulation.

  • PDF

DEVELOPMENT OF THE 5GHZ CONTINUUM RECEIVER SYSTEM (5GHZ대 연속 전파 수신 시스템의 개발)

  • Byeon, Do-Yeong;Choi, Han-Gyu;Lee, Jeong-Won;Gu, Bon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • We have developed a 5GHz continuum receiver system. The receiver is a direct type receiver. In order to reduce the noise due to the fluctuation of the gain in the amplifiers, the system employs the Dicke switching method. We made the 5GHz low-noise amplifier and the bandpass filter. The low-noise amplifier gives ${\sim}35dB$ gain and has ${\sim}210K$ noise temperature. The bandpass filter has a passband between 4.3 and 5.4GHz. We also made switch driver, video amplifiers, phase detector, and integrator. Using a 1.8 meter offset parabolic antenna, we measured the efficiency of the system. Since the antenna does not have a driver to track objects, observations were performed with the antenna fixed. The measured noise temperature of the system is ${\sim}650K$. From the observation of the blank sky, noise level was measured. It was found that the systematic noise(${\sim}0.5K$: peak to peak value) is much larger than the thermal noise. The systematic noise is possibly related to the stability of the DC power supplied to the receiver system. Besides the noise of the system, it was found that the airplanes are the very serious noise sources. We measured the radio flux of the Sun using the developed system. The observed radio flux of the Sun is ${\sim}10^6Jy$, which is close to the known value of the quiet Sun. The test observation of the Sun shows that the angular beam size of the antenna is ${\sim}2.2^{\circ}$.

  • PDF

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Enzymatic Synthesis and Characterization of Structured Lipids from Docosahexaenoic Acid - Enriched Fish oil and Soybean oil (어유와 대두유로부터 기능성 유지의 효소적 합성)

  • Kim, Yu-Mi;Jeon, Mi-Sun;Lee, Jeung-Hee;Lee, Ki-Teak
    • Food Science and Preservation
    • /
    • v.15 no.3
    • /
    • pp.437-444
    • /
    • 2008
  • Structured lipids(SLs) were synthesized by enzymatic interesterification with DHA-enriched fish oil(containing 27% docosahexaenoic acid) and soybean oil in the hatch-type reactor. The interesterification was performed for 24 hr at $55^{\circ}C$ and TLIM(immobilized lipase from Thermonyces lanuginosa, 10% by weight of total substrates) was mixed with 180 rpm of shaking. The fish oil and soybean oil were interesterifed with several weight ratio(fish oil : soybean oil, 2:8, 3:7, 4:6, 5:5, w:w), Reverse-phase high performance liquid chromatography with an evaporative light-scattering detector separated the triglyceride species of SLs. The products contained the newly synthesized peaks. Especially, one of peaks was distinctively increased with the increasing weight ratio from 2:8 to 5:5 while the peak of trilinolein (LLL) decreased vice versa. The effect of antioxidants such as catechin, BHT(Butylated hydroxytoluene), and their combinations on the oxidative stability in SL were investigated. Oxidative stability was carried out under oven test at $60^{\circ}C$ over 72 hr thereafter SLs were analyzed for total fatty acid content, rancimat, peroxide value, electronic nose and TBARS value. Among all combinations of antioxidant, the highest stability was obtained from 200 ppm of catechin. Besides, total tocopherol ($\alpha$, $\gamma$, and $\delta$-tocopherol), iodine and saponification value were analyzed in which iodine and saponification value of SLs were 151.19 and 182.35.

The Effect of Applying Self-absorption and Coincidence Summation Correction when Measuring Environmental Samples (환경시료 측정 시 자체흡수 및 동시합성 보정 적용 효과)

  • Eun-Sung Jang;Byung-In Min
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.531-539
    • /
    • 2023
  • Self-absorption is the most important factor affecting the accuracy of gamma spectroscopy measurements in environmental samples. In particular, it is affected by other factors such as the chemical composition of the sample, geometric shape, thickness, density, atomic number, distance between the sample and detector, energy of the emitted gamma photon, and humidity coefficient or percentage in the sample. To test the calibration method, a 450 ml CRM standard source (9 nuclide) Marinelli beaker was used. Five soil samples among environmental samples were measured by density by applying the corrected values. Therefore, it can be seen that the self-absorption value is more effective for somewhat large and low photon energy. In the case of environmental samples, it was confirmed that the overall energy peak efficiency through self-absorption of the source greatly depends on the density of the sample.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Quality Assessment of Ijung-tang Preparations Using a HPLC Analysis (HPLC 분석법을 이용한 이중탕(理中湯) 제제의 품질평가)

  • Ha, Woo-Ram;Park, Jin-Hyung;Yun, Dong-In;Lee, Jang-Cheon;Kim, Jung-Hoon
    • The Korea Journal of Herbology
    • /
    • v.31 no.3
    • /
    • pp.29-35
    • /
    • 2016
  • Objectives : Ijung-tang (IJT) is a traditional herbal formula and has been used to treat digestive diseases such as abdominal pain, vomiting, and diarrhea. IJT consists of four herbal medicines, Ginseng radix, Atractylodis rhizoma alba, Zingiberis rhizoma, and Glycyrrhizae radix et rhizoma, containing various bioactive compounds. Quality assesment of IJT preparations was performed by analytical method for determining marker compounds.Methods : Determination of seven marker compounds in IJT preparations was quantitatively conducted by high-performance liquid chromatography equipped with a diode-array detector. The marker compounds were separated on a reversed-phase C18 column and the analytical method was successfully validated. Chemometric analysis was performed to compare IJT water extracts and commercial IJT granules.Results : Limit of detection and limit of quantification values were in the ranges of 0.093-2.649 μg/mL and 0.283-8.027 μg/mL, respectively. Precisions were 0.30-3.87% within a day and 0.23-2.35% over three consecutive days. Recoveries of the marker compounds ranged from 87.35-107.05%, with relative standard deviation (RSD) values < 6.15%. Repeatabilities were < 1.20% and < 1.71% of RSD value for retention time and absolute peak area, respectively. The results from quantitative analysis showed that the quantities of seven marker compounds of IJT samples varied, as were found in principal component analysis and hierarchical clustering analysis.Conclusions : The analytical method developed in the present study was precise and reliable to simultaneously determine marker compounds of IJT. Therefore, it can be used for the quality assessment of IJT preparations.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.