1 |
H.J. Kim.1999. The physics and application in SPECT, Phys & High Tech). 8(7/8).
|
2 |
Jeong Rim Lee, Chang Woon Choi, Sang Moo Lim, & Seong Wun Hong.(1998) Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT. The korean Society of Nuclear Medicine. 32(4). 382-390.
|
3 |
H.K. Son, H.J. Kim, S.K. Na, & H.K. Lee).(1996). The effects of physical factors in SPECT. Korean Society of Medical Physics. 7(1). 65-77.
|
4 |
SIMON R. CHERRY, JAMES A. SORENSON, MICHAEL E. PHELPS.(2003). Physics in Nuclear Medicine. SAUNDERS. 292.
|
5 |
T. Huang, G. Yang, & G. Tang.(1979). A fast two-dimensional median filtering algorithm. IEEE Trans. Acoust., Speech. Signal Processing. 27(1). 13-18.
DOI
|
6 |
R. C. Gonzalez and R. E. woods, Eds.(2007). Digital image Processing, Prentice Hall.
|
7 |
L. Yin, R. Yang, M. Gabbouj, Y. Neuvo.(1996). Weighted median filters: a tutorial. IEEE Trans. Circuits System. 43. 157-192.
DOI
ScienceOn
|
8 |
S. Zhang & M. A. Karim.(2002). A new impulse detector for switching median filters. IEEE Signal Processing. Lett. 9(4). 360-363.
DOI
ScienceOn
|
9 |
P. Ng & K. Ma.(2006). A switching median filter with boundary discriminative noise detection for extremely corrupted image. IEEE Trans. Image Processing. 15(6). 1506-1516.
DOI
ScienceOn
|
10 |
Xu Long. & Nam Ho Kim.(2013). The Modified Median Filter using Standard Deviation in Impulse Noise Environment. J. Korea Inst. Inf. Commun. Eng. 17(7). 1725-1731.
DOI
ScienceOn
|
11 |
Kwang Soo Kang.(2011). PSNR Evaluation of Medical Images in PACS. A thesis for the degree of master. Graduate School, Nambu University. Gwangju.
|
12 |
Rousset O.G., Ma Y., & Evans A.C.(1998). Correction for partial volume effects in PET: principle and validation. THE JOURNAL OF NUCLEAR MEDICINE. 39(5). 904-911.
|
13 |
Joon Young Kim, Yong Choi, Kyung Han Lee, Sang Eun Kim, Yearn Seong Choe, Hee Kyung Ju, Yong Jin Kim, & Byung Tae Kim.(1997). A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET. J. Nucl. Med. Technol. 31(1). 73-82.
|
14 |
Rousset O.G., Collins D.L., Rahmim A., & Wong D.F.(2008). Design and implementation of an automated partial volume correction in PET: application to dopamine receptor quantification in the normal human striatum. J. Nucl. Med. 49(7). 1097-1106.
DOI
ScienceOn
|
15 |
Chen C.H., Muzic RF Jr, Nelson A.D., & Adler L.P.(1999). Simultaneous recovery of size and radioactivity concentration of small spheroids with PET data. J. Nucl. Med. 40(1). 118-130.
|
16 |
Hyun Soo Ko, Soon Ki Park, Jae Min Choi, Jung Sun Kim, & Woo Young Jung.(2011). A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect. J. Nucl. Med. Technol. 15(1). 10-16.
|