• 제목/요약/키워드: peak value

검색결과 2,393건 처리시간 0.026초

광 솔리톤 전송 시스템에 있어서 최대치 추적에 의한 상호 작용력 분석 (Interaction force analysis by peak value tracking in optical soliton transmission system)

  • 변승우;송재원
    • 전자공학회논문지A
    • /
    • 제33A권7호
    • /
    • pp.15-22
    • /
    • 1996
  • In the soliton transmission system for a long-length and high bit rate data transmission systme using the nonlinear/dispersive optical fibers, the improtant problem is the loss characteristics and is the limited transmission rate by interaction forces. In this paper, It is explained the reasons of moved time position for the soliton peak value due to interaction force sof adjacent solitons. And for the analysis of interaction force affection level in the losslessmedia, we define the percent parameter of error rate due to the interaction forces and propose the optimum time distance of adjacent solitons by peak value tracking methods. With the results, initial percent of error is approximately 50% when itme difference between adjacent solitons is 5 times of funddametnal soliton pulse width. And it is confirmed that maximum transmission length of th esolitons is approximately 38 times of fundamental soliton period, which the maximum allowable percoent of error is 50%.

  • PDF

광대역 AE 센서에 의한 유중코로나의 초음파 특성 (Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor)

  • 김인식;이상우;김성규;구경철;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2338-2340
    • /
    • 1999
  • In this paper measurements of AE (Acoustic Emission) signals caused by corona discharge were performed to analyze the electrical deterioration in oil. We also examined the relationship between discharge magnitude and peak-to-peak value of AE signals to diagnose the deterioration of liquid dielectrics. From these results, Vpp(peak to peak value) of AE signals was proportional to corona discharge magnitude. The main frequency band of AE signals in oil appeared to 130[kHz].

  • PDF

Large Solvent and Noise Peak Suppression by Combined SVD-Harr Wavelet Transform

  • Kim, Dae-Sung;Kim, Dai-Gyoung;Lee, Yong-Woo;Won, Ho-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권7호
    • /
    • pp.971-974
    • /
    • 2003
  • By utilizing singular value decomposition (SVD) and shift averaged Harr wavelet transform (WT) with a set of Daubechies wavelet coefficients (1/2, -1/2), a method that can simultaneously eliminate an unwanted large solvent peak and noise peaks from NMR data has been developed. Noise elimination was accomplished by shift-averaging the time domain NMR data after a large solvent peak was suppressed by SVD. The algorithms took advantage of the WT, giving excellent results for the noise elimination in the Gaussian type NMR spectral lines of NMR data pretreated with SVD, providing superb results in the adjustment of phase and magnitude of the spectrum. SVD and shift averaged Haar wavelet methods were quantitatively evaluated in terms of threshold values and signal to noise (S/N) ratio values.

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

활성 글루텐 첨가가 쌀베이글의 품질 특성에 미치는 영향 (Effect of Active Gluten Supplementation on the Processing and Quality of Rice Bagel)

  • 이영택;박영서
    • 산업식품공학
    • /
    • 제13권1호
    • /
    • pp.50-55
    • /
    • 2009
  • 활성 글루텐 첨가가 쌀베이글의 품질 특성에 미치는 영향을 조사하였다. 쌀가루에 글루텐 첨가량이 증가함에 따라 보수력은 증가한 반면, 알칼리수 흡수율은 감소하였다. Pelshenke값과 침전가는 글루텐의 첨가량이 증가함에 따라서 유의적으로 증가는 하였으나 강력분의 Pelshenke값과 침전가에는 미치지 못하였다. 최고점도와 setback 및 peak height와 peak width는 글루텐의 첨가량이 증가함에 따라서 감소하는 경향을 보였다. 글루텐을 23% 첨가할 경우 베이글의 부피는 글루텐 11% 첨가 후와 비교할 때 2배 이상 증가하였으며 글루텐의 첨가량이 증가할수록 베이글의 경도, 검성 및 씹힘성은 감소하는 경향을 나타내었다. 베이글의 비용적과 물 흡수력, Pelshenke값 및 침전가와는 고도의 정의 상관(r =0.962, r =0.964, r =0.966)을 나타내었다.

An Acoustic Study of Korean and English Voiceless Sibilant Fricatives

  • Sung, Eun-Kyung;Cho, Yun-Jeong
    • 말소리와 음성과학
    • /
    • 제2권3호
    • /
    • pp.37-46
    • /
    • 2010
  • This study investigates acoustic characteristics of English and Korean voiceless sibilant fricatives as they appear before the three vowels, /i/, /$\alpha$/ and /u/. Three measurements - duration, center of gravity and major spectral peak - are employed to compare acoustic properties and vowel effect for each fricative sound. This study also investigates the question of whether Korean sibilant fricatives are acoustically similar to the English voiceless alveolar fricative /s/ or to the palato-alveolar /$\int$/. The results show that in the duration of frication noise, English /$\int$/ is the longest and Korean lax /s/ the shortest of the four sounds. It is also observed that English alveolar /s/ has the highest value, whereas Korean /s/ shows the lowest value in the frequency of center of gravity. In terms of major spectral peak, while English /s/ reveals the highest frequency, English /$\int$/ shows the lowest value. In addition, evidence indicates that there is a strong vowel effect in the fricative sounds of both languages, although the vowel effect patterns of the two languages are inconsistent. For instance, in the major spectral peak, both Korean lax /s/ and tense /$s^*$/ show significantly higher frequencies before the vowel /$\alpha$/ than before the other vowels, whereas both English /s/ and /$\int$/ exhibit significantly higher frequencies before the vowel /i/ than before the other vowels. These results indicate that Korean sibilant fricatives are acoustically distinct from both English /s/ and /$\int$/.

  • PDF

Peak 검출과 AMDF에 의한 고속도 음성주기 추출방법 (A High Speed Pitch Extraction Method Based on Peak Detection and AMDF)

  • 성원용;은종관
    • 대한전자공학회논문지
    • /
    • 제17권4호
    • /
    • pp.38-44
    • /
    • 1980
  • 본 논문에서는 peak 검출과 average magnitude difference function (AMDF)방법을 이용해서 음성의 주기를 고속도로 추출하는 방법이 연구되었다. 먼저 입력 음성을 800Hz로 대역폭을 줄인다음 Pitch peak가 될 만한 몇개의 Peak을 검출한다. 그 다음 이들 peak들의 값을 갖고 AMDF를 계산해서 이들 값들 중에서 최소의 AMDF치를 갖는 peak를 원하는 음성주기로 결정을 한다. 이 방법을 사용하여 음성의 주기를 검출하면 타 음성주기 추출방법 보다 훨씬 적은 계산 시간이 소요될 분만 아니라 비교적 정확한 결과를 얻을 수 있다.

  • PDF

Mini-Wright Peak Flow Meter로 측정한 한국 성인의 최고호기유량의 정상치 (Peak Expiratory Flow in Normal Healthy Korean Subjects Measured by Mini-Wright Peak Flow Meter)

  • 김영삼;안애란;김세규;장준;안철민;오재준;김성규
    • Tuberculosis and Respiratory Diseases
    • /
    • 제50권3호
    • /
    • pp.320-333
    • /
    • 2001
  • 연구배경 : 최고호기유량은 비교적 간단하고, 반복적으로 기도폐쇄의 정도를 양적으로 나타낼 수 있는 수치로, 최근 천식의 치료방침을 결정하는데 있어 최고호기유량 측정의 중요성을 강조하고 있다. 외국에서는 정상 성인에서의 최고호기유량의 추정정상치를 구하기 위한 대규모 단변연구가 시행되었으나 1991년 American Lung Association에서 정한 기준을 정확히 적용하여 추정정상치 뿐만 아니라, 최고호기유량의 정규분포성을 검정하고 정상치의 하한선까지 제시한 대규모 단면연구가 시행되지 않았다. 이번 연구를 통해 정상 성인을 대상으로 한국인에서의 추정정상치를 구해 이전의 연구결과 및 외국인을 대상으로 한 연구결과와 비교하며, 정상치의 하한선을 구함으로써 한국인에서의 최고 호기유량의 특성을 알아보고자 하였다. 방 법 : 1997년 8월부터 2000년 1월까지 세브란스 건강검진센터에 내원한 정상 성인 중 과거에 폐질환을 앓은 적이 있거나, 호흡기 증상을 호소하거나 흡연을 한 적이 없는 남성 233명과 여성 631명을 대상으로 Mini Wright Peak Flow Meter와 Jaeger Master Lab의 폐기능검사기를 이용하여 최고호기유량을 측정한 후 다중회귀분석을 시행하여 정상추정치에 대한 회귀방정식을 구하였다. 또한 최고호기유량의 정규분포성에 대한 검정을 시행한 후 정상치의 하한선에 대한 회귀방정식을 구하고 이를 외국 및 이전에 한국에서 시행한 연구결과와 비교하였다. 결 과 : Mini Wright Peak Flow Meter를 이용하여 측정 한 최고호기유량의 정상추정치 (PEF : L/min)는 남성에서는 $25.117+4.587{\times}$연령(year)-$0.064{\times}$연령$^2+2.931{\times}$신장(cm)이었고($R^2=025$), 여성에서는 $146.942-0.011{\times}$연령$^2+1.795{\times}$신장(cm)+$0.836{\times}$체중(kg)이었다($R^2=0.21$). 최고호기유량의 정상치의 하한선은 남성에서는 $25.117+4.587{\times}$연령(year)-$0.064{\times}$연령$^2+1.936{\times}$신장(cm)이었고, 여성에서는 $146.942-0.011{\times}$연령$^2+1.232{\times}$신장(cm)+$0.481{\times}$체중(kg)이었다. 최고호기유량은 정규분포를 하였다. 남성에서 Mini-Wright Peak Flow Meter로 측정한 한국인의 최고호기유량의 정상추정치는 영국인 및 일본인의 수치와 유사하였다. 여성에서 Mini-Wright Peak Flow Meter로 측정한 한국인의 최고호기유량의 정상추정치는 영국인의 수치와 유사하였고 일본인의 수치보다는 높았다. 남성에서는 정상추정치의 71% 이하를 여성에서는 정상추정치의 76% 이하를 비정상적인 수치를 볼 수 있었다. 결 론 : 호흡기질환이 없는 건강한 남성 233명과 여성 631 명을 대상으로 Mini Wright Peak Flow Meter로 최고호기유량을 측정하여 정상추정치 및 정상치의 하한선을 구하였다. 이는 외국인을 대상으로 한 연구결과와 차이를 보였고, 한국인을 대상으로 한 이전 연구결과와도 차이가 있었다. 향후 한국인을 대상으로 한 최고호기유량의 정상추정치에 대한 연구가 계속 진행되어야 할 것이다.

  • PDF

Peak Detector를 이용한 펄스방사선 선량 측정 (Pulse Radiation Dose Measurement using the Peak Detector)

  • 정상훈;이남호;오승찬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1020-1022
    • /
    • 2013
  • 본 논문에서는 펄스방사선 선량 측정을 위한 Peak Detector를 설계하였다. 펄스방사선은 수ns ~ 수십ns의 초고속의 신호로 Peak 값을 측정하기 어렵다. Peak Detector는 센서에서 발생한 Peak 전압을 수ms 동안 유지하므로 ADC를 이용하여 데이터를 쉽게 측정할 수 있다. Peak Detector 시뮬레이션 결과 Peak 값을 1ms 이상 유지하는 것을 확인하였으며 펄스방사선 조사시험 결과 $1.95{\times}10^6rad/s$의 선량을 확인하였다.

  • PDF

손과 액세서리에 의한 휴대폰 전자파의 인체 노출 특성 (Influences of Mobile Phone Electromagnetic Wave on Human Body According to Holding Method by the Hand and Wearing Accessories)

  • 최명선;장영호;김윤명;박한규
    • 한국전자파학회논문지
    • /
    • 제16권6호
    • /
    • pp.652-660
    • /
    • 2005
  • 본 논문에서는 현재 권고되고 있는 측정방법이 최대 SAR를 측정할 수 있는 조건인지를 판단하기 위하여 손으로 휴대폰을 잡고 있을 때와 손을 사용하지 않았을 때 및 액세서리 사용 여부에 따른 국부 SAR(Specific Absorption Rate)를 비교 분석하였다. 손의 영향을 측정하기 위하여 바(Bar)형과 폴더(Folder)형 휴대폰을 잡는 형태에 따라 2가지 손 팬텀을 제작하였으며, 액세서리의 영향을 측정하기 위하여 각각 3가지 형태의 귀걸이와 안경을 사용하였다. 분석 결과, 손의 영향으로 인하여 머리의 국부 SAR 값이 상당히 감소하였다. 귀걸이에 의한 영향은 없었으며, 안경을 사용할 경우 바형 휴대폰에서는 머리의 국부 SAR 값을 상당히 증가시키고 있으나 폴더형 휴대폰에서는 영향이 없는 것으로 나타났다.