• Title/Summary/Keyword: peak to peak analysis

Search Result 4,721, Processing Time 0.038 seconds

Flood Runoff Characteristics in Urbanized Basin (도시화 유역에서의 홍수 유출 특성)

  • 한국희;이길춘
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.153-161
    • /
    • 1996
  • This study is runoff analysis of the recently urbanized San Bon basin. The relationships between peak discharge and total discharge were examined by applying the ILLUDAS runoff analysis model to the measured data. In urbanized streams, it is found that channel adjustment had the most significant effect on the increase of peak discharge. Significant increases in the peak discharge occurred as rainfall duration or return period increases 10% and 7~16% increases in peak discharge were observed when the roughness coefficient were 0.04 and 0.015, respectively. When the natural river channel with n=0.04 was converted into a sewerage system of n=0.015 the peak discharge was greatly increased by 51~158%, Generally, flood peak discharge was increased during heavy rain, but in the case of urbanized basin, river stage was reduced owing to an increase of flow velocity by the adjustment of drainage system.

  • PDF

Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis (관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석)

  • You, Jang-Youl;Kim, Geun-Ho;Chae, Myung-Jin;Kim, Young-Moon;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

The Technology of Peak Demand Reduction using Automatic Water Tank Pumping System on the Apartment And Analysis of Effect of Energy Cost (아파트 고가수조 자동급수장치를 이용한 전력피크 감소 및 전력시장에서의 효과 분석)

  • Lee, Jae-Gul;Lee, Yun-Kyoung;Cho, Won-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.161-163
    • /
    • 2006
  • This paper introduce the technology of peak demand reduction using automatic water tank pumping system on the apartment. That systems on the apartments installed water tank can control pumping(electricity) demand. Generally, system peak demand is occurred at the same time on workday and many water pumps consume electric power randomly. At this point, shift of operating time of water pump can reduce peak demand using automatic water tank pumping system. We were operating this system on some apartments for test of effect of peak demand reduction. and we represent result of demand shift. This result suggests that spread of the automatic water pumping system can contribute to reduce system peak demand and reduce system operation cost.

  • PDF

Determination of Single Escape and Double Escape Peak Efficiency for a HPGe Detector

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.523-528
    • /
    • 2003
  • The efficiencies of single escape and double escape peaks were calculated by using Monte Carlo method and compared with measured efficiencies. The efficiency was obtained from the area ratio of escape peak to full energy absorption peak and the full energy absorption peak efficiency. For the escape peak interfered with other $\gamma-ray$ peaks, the net area was obtained by area correction. The GEANT code developed in CERN was used for the Monte Carlo calculation. The calculated efficiencies of the escape peaks agreed with the measurement within $12\%$.

Measurement of Fishing Capacity of Offshore Fisheries in Korea (우리나라 근해어업의 어획능력 측정에 관한 연구)

  • Kim Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.37 no.1 s.70
    • /
    • pp.1-24
    • /
    • 2006
  • Reducing fishing capacity is one of current issues in the international fisheries. This is because that increased fishing capacity has caused not only fish stocks to be depleted, but also additional fishing costs to be incurred, which resulted in reduction of economically viability of fisheries. For this reason, FAO adopted the International Plan of Action for the Management of Fishing Capacity' in 1999 and recommended member countries to estimate fishing capacity and to implement the policy to reduce fishing capacity. This study is aimed to measure fishing capacity of the Large Purse Seines Fishery that is one of offshore fisheries in Korea using both Peak - to - Peak Analysis and Data Envelopment Analysis in order to provide a policy information for preparation of domestic plan of action for the management of fishing capacity. The results of PTP Analysis were almost similar to those of DEA Analysis. The DEA results showed that the capacity utilization in 2004 was about 75%, it was obvious the capacity did not utilize enough. The sensitivity analysis on DEA results indicated that 24% of the number of ships, 26% of the tonnages, or 29% of the horse powers should be reduced if the present catch remained. In addition, if the catch remains at the MSY base level of large purse seines, the analysis suggested that the number of ships, tonnages and horse powers should be reduced by 15%, 18%, and 21% respectively.

  • PDF

Antibacterial Activity and Component Analysis of Persicaria perfoliata Extracts (며느리배꼽 추출물의 항균 작용과 성분 분석)

  • Kim, Sun-Young;Won, Doo-Hyun;Park, Soo-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.3
    • /
    • pp.278-282
    • /
    • 2010
  • In this study, the antibacterial activity and component analysis of Persicaria perfoliata extracts were investigated. MIC (Minimum Inhibitory Concentration) values of ethyl acetate fraction from P. perfoliata on Escherichia coli, Propionibacterium acnes, and Staphylococcus aureus were 0.25%, equally. The results showed that the antibacterial activity of the ethyl acetate fraction was the highest in the S. aureus and P. acnes. Ethyl acetate fraction from P. perfoliata extracts showed 5 bands in TLC and 8 peaks in HPLC (320nm). In HPLC chromatogram of ethyl acetate fraction, first main peak 2 (24.99%) and peak 3 (22.65%) were identified as quercetin-3-o-glucuronide and isoquercitrin in the order of elution time. Also, in HPLC chromatogram of deglycosylated fraction, main peak 2 (76.93%) was identified as quercetin in the order of elution time. And these components are very effective as antioxidants. Thus, these results indicate that extract/fractions of P. perfoliata can be applicable to new functional cosmetics for antioxidant, antibacterial activity.

Correlation Between Collimation-Corrected Peak Luminosity and Spectral Lag of Gamma-ray Bursts in the Source Frame

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.3
    • /
    • pp.253-258
    • /
    • 2012
  • We revisit the relation between the peak luminosity $L_{iso}$ and the spectral time lag in the source frame. Since gamma-ray bursts (GRBs) are generally thought to be beamed, it is natural to expect that the collimation-corrected peak luminosity may well correlate with the spectral time lag in the source frame if the lag-luminosity relation in the GRB source frame exists. With 12 long GRBs detected by the Swift satellite, whose redshift and spectral lags in the source frame are known, we computed $L_{0,H}$ and $L_{0,W}$ using bulk Lorentz factors ${\Gamma}_{0,H}$ and ${\Gamma}_{0,W}$ archived in the published literature, where the subscripts H and W represent homogeneous and wind-like circumburst environments, respectively. We have confirmed that the isotropic peak luminosity correlates with the spectral time lag in the source frame. We have also confirmed that there is an anti-correlation between the source-frame spectral lag and the peak energy, $E_{peak}$ (1 + z) in the source frame. We have found that the collimation-corrected luminosity correlates in a similar way with the spectral lag, except that the correlations are somewhat less tight. The correlation in the wind density profile seems to agree with the isotropic peak luminosity case better than in the homogeneous case. Finally we conclude by briefly discussing its implications.

Optimal Annealing of Natural Beryl for Thermoluminescent Dosimetry

  • Moon, Philip S.
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.3-8
    • /
    • 1974
  • The annealing of natural beryl powder used for the thermoluminescent dosimetry was investigated in order to eliminate effect of previous exposure. Through the glow curve analysis, the optimal annealing treatment was found to be one hour annealing at 145$0^{\circ}C$, but annealing for one hour at 55$0^{\circ}C$ was sufficient for reuse of natural beryl powder. There are two distinguished glow peaks at $65^{\circ}C$ and 20$0^{\circ}C$ of heating temperature during readout process. The $65^{\circ}C$ glow peak fades away rapidly, but the 20$0^{\circ}C$ glow peak remains very stable. It is, therefore, quite feasible to use the 20$0^{\circ}C$ glow peak for thermoluminescent dosimetry.

  • PDF

Volumetric Thermal Analysis of Hydrogen Desorption from Mg-13.5wt%Ni Hydride (Mg-13.5wt%Ni 합금 수소화합물의 수소방출에 대한 부피법에 의한 열분석)

  • HAN, JEONG SEB;PARK, KYUNG DUCK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.308-317
    • /
    • 2015
  • To investigate the effect of microstructure on the formation of the desorption peak, the volumetric thermal analysis technique (VTA) was applied to the Mg-13.5 wt% Ni hydride system. The sample made by the HCS (hydriding combustion synthesis) process had two kinds of Mg microstructures. Linear heating was started with various constant heating rates. Only one peak was appeared in the case of the small initial hydrogen wt% (0.83 wt%). Yet, two peaks were appeared with increasing initial hydrogen wt% (1.85 and 3.73 wt%) when only Mg was hydrogenated. The first peak was formed through the evolution of hydrogen from $MgH_2$, made by eutectic Mg. The second peak was formed through the evolution of hydrogen from $MgH_2$, made by primary Mg. Therefore, this result shows that the microstructure also has a considerable effect on forming the desorption peak. We have also derived the hydrogen desorption equations by VTA to get apparent activation energy when the rate-controlling step for the desorption of the hydrided system is the diffusion of hydrogen through the ${\alpha}$ phase and the chemical reaction ${\beta}{\rightarrow}{\alpha}$.

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.