• Title/Summary/Keyword: peak time

Search Result 4,630, Processing Time 0.042 seconds

A Study on the Effects of Muscle Membrane in Tension Development (장력발생이 근육 분자막에 미치는 영향에 관한 연구)

  • Kim, Duck-Sool;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.47-54
    • /
    • 1998
  • On contraction of the muscles, marked changes in X-ray reflections are observed, suggesting that conformational changes of contractile molecules and the movement of myosin heads during muscle contraction. The time needed to the peak tension after the onset of stimulation and the amount of peak tension depend on the number of twitch cycle. It was found that the successive twitches decreased not only the time needed to the peak tension after the onset of stimulation but also the time needed to the maximum change of the X-ray intensity. However, the difference of the time between the peak tension and the maximum intensity change($T_{i}-I_{i}$) is nearly the same at any twitch. Based on these results the causes of the decrease of $T_{i}$ and $I_{i}$, and physiological implication of $T_{i}-I_{i}$ are discussed.

Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured Using a Clip-type Pulsimeter Equipped with a Permanent Magnet and a Hall Device

  • Kim, Keun-Ho;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • We measured radial arterial pulse signals using a prototype of a clip-type pulsimeter equipped with a permanent magnet and a Hall device, which produced signals through a voltage-detecting circuit. The systolic peak time and the reflective peak time for a temporally pulsed signal were analyzed for an arbitrary pulse wave at one position of a small permanent magnet. The measured value of the peripheral pulse wave velocity was about 1.25-1.52 m/s, demonstrating the accuracy of this new method. To measure the peripheral blood flow velocity, we simultaneously connected the radial artery pulsimeter to a photoplethysmography meter. The average value of the peripheral blood flow velocity was about 0.27-0.50 m/s.

Effect of irrigation reservoir, antecedent soil moisture condition and Huff time distribution on peak discharge in a basin (농업용 저수지, 선행토양함수조건 및 Huff 시간 분포가 유역의 첨두홍수량에 미치는 영향 분석)

  • Kwon, Minsung;Ahn, Jae-Hyun;Jun, Kyung Soo;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.5
    • /
    • pp.417-424
    • /
    • 2018
  • This study analyzed the effect of irrigation reservoirs, antecedent soil moisture conditions (AMC) and Huff time distribution on peak discharge using Monte Carlo simulation. The peak discharge was estimated for four different cases in combination of irrigation reservoir capacity, AMC, and Huff time distribution. Applying 100% reservoir capacity or AMC-III, the peak discharges corresponding return periods of 50~300 years were overestimated by 25~30% compared to those of cases that considered the probability of occurrence for individual condition. Applying the 3rd quantile huff distribution, the peak discharges were overestimated by 5% over the peak discharge that considered the probability of occurrence. The overall results indicated that the effect on the peak flood of Huff distribution was less than AMC and reservoir storage.

A comprehensive analysis of temporal characteristics in independent rainstorm events in Seoul: focusing on changes in unit time and secondary peak constant (서울특별시 내 독립 호우사상의 시간분포 특성 분석: 분 단위와 차첨두 상수의 조건 변화를 중심으로)

  • Cha, Hoyoung;Lee, Jinwook;Jun, Changhyun;Byun, Jongyun;Baik, Jongjin
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.785-799
    • /
    • 2023
  • In this study, we proposed a new concept termed the Secondary Peak Constant (SPC) and discerned the temporal characteristics of independent rainstorm events based on unit time and SPC about 24 observation stations in Seoul. Utilizing rainfall observations from 2000 to 2022, independent rainstorm events discreted from rainfall data per unit time. The temporal characteristics of these events were derived according to unit time, and temporal characteristics of the peak rainfall were identified through the SPC. Finally, the temporal characteristics of independent rainstorm events were examined distinctively when analyzed by unit time and SPC. Independent rainstorm events with smaller unit time showed significantly larger total rainfall, rainfall duration, and rainfall intensity. The temporal characteristics of the largest peak rainfall (1st Peak) within independent rainstorm events followed a sequence of Q4>Q2>Q3>Q1. Additionally, the 2nd Peak rainfall predominantly occurred the location where the 1st Peak appeared. The proportion of independent rainstorm events with multiple peak rainfalls exceeded 50.0% when the SPC was 0.7 or lower. The average number of peak rainfalls within independent rainstorm events ranged from 1.5 to 3.4. This study identified the temporal characteristics of independent rainstorm events based on unit time. Then, the peak rainfall of temporal characteristics was quantified by SPC on this study. Hence, it is evident that the temporal characteristics of independent rainstorm events for specific area can be anlayzed and quantified based on unit time and SPC.

Novel Fast Peak Detector for Single- or Three-phase Unsymmetrical Voltage Sags

  • Lee, Sang-Hoey;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.658-665
    • /
    • 2011
  • In the present paper, a novel fast peak detector for single- or three-phase unsymmetrical voltage sags is proposed. The proposed detector is modified from a single-phase digital phase-locked loop based on a d-q transformation using an all-pass filter (APF). APF generates a virtual phase with $90^{\circ}$ phase delay. However, this virtual phase cannot reflect a sudden change of the grid voltage in the moment of voltage sag, which causes a peak value to be significantly distorted and to settle down slowly. Specifically, the settling time of the peak value is too long when voltage sag occurs around a zero crossing, such as phase $0^{\circ}$ and $180^{\circ}$. This paper describes the operating principle of the APF problem and proposes a modified all-pass filter (MAPF) to mitigate the inherent APF problem. In addition, a new fast peak detector using MAPF is proposed. The proposed detector is able to calculate a peak value within 0.5 ms, even when voltage sag occurs around zero crossing. The proposed fast peak detector is compared with the conventional detector using APF. Results show that the proposed detector has faster detection time in the whole phase range. Furthermore, the proposed fast peak detector can be effectively applied to unsymmetrical three-phase voltage sags. Simulation and experimental results verify the advantages of the proposed detector and MAPF.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects (뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究))

  • Ko, Ki-Duk;Kim, Kyung-Yo;Kim, Jong-Yeol;Lee, Si-Woo;Joo, Jong-Cheon
    • Journal of Pharmacopuncture
    • /
    • v.10 no.2 s.23
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

Identification of unit hydrograph peak behavior according to changes in precipitation scale in a virtual watershed (가상 유역의 강수 규모 변화에 따른 단위유량도 첨두치의 거동 규명)

  • Yoo, Ju-Hwan;Kim, Joo-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.655-665
    • /
    • 2023
  • In this study, unit hydrographs are calculated when precipitations of 10 scales instantaneously occurs in a virtual watershed with a constant slope and roughness. Then, the relationship between the peak flow rate and the peak occurrence time of the unit hydrograph was calculated for the precipitation scale, respectively. At this time, the virtual watershed simplified with a rhombic shape, a constant slope, and a flow condition with a certain roughness was applied instead of a natural watershed in order to understand the effect the precipitation scale has on the peak value of the unit hydrograph. And it was assumed that the precipitation in the basin was effective rainfall and the runoff was direct runoff, and the runoff flowed in a straight, uniform flow from the drop point to the outlet. The relationship between the peak flow and the peak occurrence time of the unit hydrograph was calculated in the case of 10 types of precipitation scales of 10 mm, 40 mm, 90 mm, 160 mm, 250 mm, 360 mm, 640 mm, 1,000 mm, 1,210 mm, and 1,690 mm of effective precipitation. A noteworthy achievement of this study is that, even without the storage effect of the watershed, as the scale of precipitation increases, the depth of runoff increases, so the flow rate in the watershed increases and the distance per unit time increases, so the peak flow rate increases and the peak occurrence time increases. This is a nonlinear characteristic of watershed runoff.

The Technology of Peak Demand Reduction using Automatic Water Tank Pumping System on the Apartment And Analysis of Effect of Energy Cost (아파트 고가수조 자동급수장치를 이용한 전력피크 감소 및 전력시장에서의 효과 분석)

  • Lee, Jae-Gul;Lee, Yun-Kyoung;Cho, Won-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.161-163
    • /
    • 2006
  • This paper introduce the technology of peak demand reduction using automatic water tank pumping system on the apartment. That systems on the apartments installed water tank can control pumping(electricity) demand. Generally, system peak demand is occurred at the same time on workday and many water pumps consume electric power randomly. At this point, shift of operating time of water pump can reduce peak demand using automatic water tank pumping system. We were operating this system on some apartments for test of effect of peak demand reduction. and we represent result of demand shift. This result suggests that spread of the automatic water pumping system can contribute to reduce system peak demand and reduce system operation cost.

  • PDF

Mixed Integer Programming (MIP)-based Energy Storage System Scheduling Method for Reducing the Electricity Purchasing Cost in an Urban Railroad System (도시철도 시스템 전기요금 절감을 위한 혼합정수계획법 기반 ESS(에너지저장장치) 스케줄링 기법)

  • Ko, Rakkyung;Kong, Seongbae;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1125-1129
    • /
    • 2015
  • Increasing peak load is one of the major concerns about operation of urban railroad systems. Since ESSs (Energy Storage Systems) have a great potential for shaving the peak load, there has been a growing interest in the use of ESS for peak load reduction. Also, ESS can be optimally scheduled to minimize the electricity purchasing cost under a given ToU (Time-of-Use) tariff by taking advantage of electricity price difference between peak and off-peak time. This paper presents a Mixed Integer Programming (MIP)-based ESS scheduling method to minimize the electricity purchasing cost under a ToU tariff for an urban railroad system.

Precise Analytical Solution for the Peak Gain of LLC Resonant Converters

  • Hong, Sung-Soo;Cho, Sang-Ho;Roh, Chung-Wook;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.680-685
    • /
    • 2010
  • Although LLC resonant converters have the advantages of a wide operation range and high efficiency, the lack of an analytical solution for the peak gain makes it difficult to optimize the resonant tank design, when considering not only the normal condition but also the holdup time requirement. In this paper, based on a mathematical analysis of a LLC resonant converter at the peak gain point, an analytical solution for the peak gain has been developed. By using the developed analytical solution, the peak gain with given resonant tank parameters can be obtained. To confirm the validity of the developed analytical solution, simulations and experimental results are compared.