• Title/Summary/Keyword: peak power

Search Result 2,628, Processing Time 0.026 seconds

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

Preliminary Research of CZT Based PET System Development in KAERI

  • Jo, Woo Jin;Jeong, Manhee;Kim, Han Soo;Kim, Sang Yeol;Ha, Jang Ho
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a $19.4{\times}19.4{\times}6mm^3$ volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of $8mV{\cdot}fC^{-1}$ and noise of 55 equivalent noise charge (ENC), a $CR-RC^4$ shaping amplifier with a $5{\mu}s$ peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a $^{22}Na$ gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

The Effect of Lightly Gripping a Cane on Sit-to-stand Transfer in Post-stroke Patients

  • Choi, Young-eun;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.54-59
    • /
    • 2017
  • Background: Light touch cue is a sensory input that could potentially help in the control of posture. The immediate stimulatory effect of light touch cues using a cane during gait is associated with postural stability. This strategy can help post-stroke individuals regain their ability to perform the sit-to-stand (STS) transfer safely. Objects: The effects of light grip on postural control during the STS transfer in post-stroke subjects were investigated. Methods: Eleven participants (6 men, 5 women) with hemiplegia due to stroke were recruited in the study. The subjects with hemiparesis performed STS transfer in three randomly assigned conditions (1) without a cane (2) light grip with a cane (3) strong grip with a cane. Results: The difference in weight-bearing distribution between the left and right feet, when the subjects were instructed to stand up, was $52.73{\pm}2.13%$ without a cane, $42.75{\pm}3.26%$ with a strong grip, and $43.00{\pm}2.55%$ with a light grip (p<.05). The rate of rise in force indicates the peak power provided by subjects during their STS transfers. The rate of rise in force was statistically significantly lower without a cane than that with a light grip or a strong grip (p<.05). The subjects' centers of pressure sway on the mediolateral side during STS transfers statistically significantly declined with a light grip or a strong grip when compared to those without a cane (p<.05). Conclusion: When the subjects with hemiparesis used a cane during STS transfers, their duration, center of pressure sway, and difference in weight-bearing distribution were all reduced. The subjects also exhibited similar results during STS transfers with a cane gripped lightly. This result may provide guidelines for the use of assistive devices when patients with hemiparesis practice STS transfers in clinical settings.

A Study on PAR Improvement of OFDM system using SLM-PTS Combine Method and ETD-Turbo Code (SLM-PTS 결합기법 및 ETD-Turbo부호를 적용한 OFDM 시스템에서의 PAR 개선에 관한 연구)

  • Sung Tae-Kyung;Kim Dong-Seek;Cho Hyung-Rae
    • Journal of Navigation and Port Research
    • /
    • v.29 no.8 s.104
    • /
    • pp.755-761
    • /
    • 2005
  • In this paper, we propose a high-speed adaptive PTS method which eliminates high PAR (Peak-to-Average Power Ratio) and we compare the proposed method with other conventional methods. In addition, we have designed a combined type SLM-PTS scheme to reduce PAR and evaluate the performance. The system used for evaluating PAR performance can be constructed as COFDM (Coded Orthogonal Frequency Division Multiplexing) applying ETD(Enhabced Time Diversity)-Turbo coding scheme. All the analyses in this paper are focused on the system characteristics according to IFFT's point and modulation method and the performance evaluation are based on the PAR reduction rates. As a result, the SLM-PTS combination method reveals good PAR reduction rate and remarkable reduction in the amount of calculations. Especially, in the case of combine-3 scheme, we can achieve approximately $3.7\~3.9$ dB PAR reduction on a basis of 10-5 BER level. Moreover, we can eliminate the side information in COFDM system because of its adaptive characteristics in evaluating PAR reduction rate, so that the additional errors can be omitted.

5.0 inch WVGA Top Emission AMOLED Display for PDA

  • Lee, Kwan-Hee;Ryu, Seoung-Yoon;Park, Sang-Il;Ryu, Do-Hyung;Kim, Hun;Song, Seung-Yong;Chung, Bo-Yong;Park, Yong-Sung;Kang, Tae-Wook;Kim, Sang-Chul;Cho, Yu-Sung;Park, Jin-Woo;Kwon, Jang-Hyuk;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.7-10
    • /
    • 2003
  • Samsung SDI has developed a full color 5.0" WVGA AMOLED display with top emission and a super fine pitch of 0.1365mm(l86ppi), the world's highest resolution OLED display ever reported to date. Scan driver circuits and demux circuit were integrated into the display panel, using low temperature poly-Si TFT CMOS technology, and data driver circuit were mounted using COG chips. Peak luminescence was greater than 300cd/ $m^2$ with power consumption of 500mW with 30% of the pixels on illuminated.

  • PDF

Etching Characteristics of YMnO3 Thin Films in Cl Based Inductively Coupled Plasma

  • Kim, Dong-Pyo;Kim, Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.29-34
    • /
    • 2003
  • Ferroelectric YMnO$_3$ thin films were etched with Ar/C1$_2$ and CF$_4$/C1$_2$ Plasma. The maximum etch rate of YMnO$_3$ thin film was 300 $\AA$/min at a Cl$_2$/Ar gas mixing ratio of 8/2, an RF power of 800 W, a do bias of-200 V, a chamber pressure of 15 mTorr, and a substrate temperature of 3$0^{\circ}C$. From the X-ray photoelectron spectroscopy (XPS) analysis, yttrium was not only etched by chemical reactions with Cl atoms, but also assisted by Ar ion bombardments in Ar/C1$_2$ plasma. In CF$_4$/C1$_2$ plasma, yttrium formed nonvolatile YF$_{x}$ compounds and remained on and the etched surface of YMnO$_3$. Manganese etched effectively by forming volatile MnCl$_{x}$ and MnF$_{y}$. From the X-ray diffraction (XRD) analysis, the (0004) diffraction peak intensity of the YMnO$_3$ thin film etched in Ar/Cl$_2$ plasma shows lower than that in CF$_4$/Cl$_2$ plasma. It indicates that the crystallinty of the YMnO$_3$ thin film is more easily damaged by the Af ion bombardment than the changes of stoichiometry due to nonvolatile etch by-products.cts.s.

Fabrication of Transparent Ultra-thin Single-walled Carbon Nanotube Films for Field Emission Applications

  • Jang, Eun-Soo;Goak, Jung-Choon;Lee, Han-Sung;Kim, Myoung-Su;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.353-353
    • /
    • 2008
  • Carbon nanotubes (CNTs) are attractive for field emitter because of their outstanding electrical, mechanical, and chemical properties. Several applications using CNTs as field emitters have been demonstrated such as field emission display (FED), backlight unit (BLU), and X-ray source. In this study, we fabricated a CNT cathode using transparent ultra-thin CNT film. First, CNT aqueous solution was prepared by ultrasonically dispersing purified single-walled carbon nanotubes (SWCNTs) in deionized water with sodium dodecyl sulfate (SDS). To obtain the CNT film, the CNT solution in a milliliter or even several tens of micro-litters was deposited onto a porous alumina membrane through vacuum filtration process. Thereafter, the alumina membrane was solvated by the 3 M NaOH solution and the floating CNT film was easily transferred to an indium-tin-oxide (ITO) glass substrate of $0.5\times0.5cm^2$ with a film mask. The transmittance of as-prepared ultra-thin CNT films measured by UV-Vis spectrophotometer was 68~97%, depending on the amount of CNTs dispersed in an aqueous solution. Roller activation, which is a essential process to improve the field emission characteristics of CNT films, increased the UV-Vis transmittance up to 93~98%. This study presents SEM morphology of CNT emitters and their field emission properties according to the concentration of CNTs in an aqueous solutions. Since the ultra-thin CNT emitters prepared from the solutions show a high peak current density of field emission comparable to that of the paste-base CNT emitters and do not contain outgassing sources such as organic binders, they are considered to be very promising for small-size-but-high-end applications including X-ray sources and microwave power amplifiers.

  • PDF

Phase Noise Compensation in OFDM Communication System by STFBC Method (OFDM 통신 시스템에서 STFBC 기법을 이용한 위상잡음 보상)

  • Li Yingshan;Ryu Heung-Gyoon;Jeong YoungHo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1043-1049
    • /
    • 2005
  • In OFDM system suitable for high capacity high speed broadband transmission, ICI caused by phase noise degrades system performance seriously by destroying the orthogonality among subcarriers. In this paper, a new STFBC method combining ICI self cancellation scheme and antenna, time, frequency diversity is studied to reduce ICI effectively. CPE and ICI are analyzed by the phase noise linear approximation method in the proposed STFBC OFDM system. CIR, PICR and BER are discussed to compare the system performance degraded by phase noise of PLL. As results, STFBC method significantly reduces ICI. Furthermore, the SCI that usually happens in the traditional STBC, SFBC diversity coding method can be easily avoided.

Analysis of Distortion Characteristic of Amplitude Modulated Signal through a Current-Mode-Logic Frequency Divider (전류모드논리 주파수 분할기를 통한 기저대역 AM 변조 신호의 왜곡 특성 연구)

  • Kim, Hyeok;Park, Youngcheol
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.7
    • /
    • pp.620-624
    • /
    • 2016
  • In this paper we designed a current mode logic frequency divider to transmit a baseband amplitude modulated signal. From simulation result, we studied input and output waveforms according to the variation of input bias voltage. For the purpose of the verification of the study, we designed a current mode logic frequency divider at 1,400 MHz. The designed frequency divider operates between 100 MHz and 3,000 MHz, for -33 dBm input power. The circuit draws $I_{total}=30mA$ from $V_{DD}=3V$ supply, and the simulation result shows that an amplitude modulated signal at 1,400 MHz with the modulation index of 0.5 was successfully downconverted to 700 MHz.

A Study on the Electrical Discharge Machining Tap by using Cu Electrodes of the Cold-Work Tool Steel (냉간 금형용 공구강의 Cu 전극을 이용한 방전 탭에 관한 연구)

  • Lee, Eun-Ju;Park, In-Soo;Kim, Hu-Kwon;Wang, Duck-Hyun;Chung, Han-Shik;Lee, Kwang-Sung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.131-136
    • /
    • 2016
  • Currently, an EDM tapping procedure has comprised some parts of the engraving discharge process for the press die. Usually, tapping has been used in cases where we are unable to mechanically machine using steelwork processes due to an increase in the hardness of a material after heat treatment in relation to a design change or missing process. Here, we analyze the influence of discharge tap shape on discharge time, discharge current, and the number of repetition conditions when a cold-work tool steel (STD11) has been treated with a discharge tapped by a screw-shaped cu electrode. The most important influence on processing condition has been determined to be the number of discharge repetitions. As this number increases, the angle reduction of a thread closes to an angle of the electrode via a power generation reduction. The optimal combination of conditions has been determined to be three discharge repetitions, $180{\mu}s$ of discharge time (same as existing regulations), and 25.4A of peak current. A 0.2749db advantage has emerged after comparing between this combination of optimal conditions and the SN rate of existing regulations.