• Title/Summary/Keyword: pattern blocks

Search Result 225, Processing Time 0.041 seconds

The Analysis of Effect of Surface Shape and Pattern of Noise Barrier Panel on the Noise Reduction (방음벽 전면형상에 따른 소음 효과 분석에 관한 연구)

  • Kim, IlHo;Ahn, Hosang;Park, Jong-Bin;Kim, Gwang Soo;Lee, Ju Haeng;Ko, Junhee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.835-839
    • /
    • 2012
  • In recent decades, a lot of noise barriers have been installed along paved road in order to reduce the road induced noise, which increases as traffic volume grows. For better range of sight, transparent noise barriers are widely installed despite of reflecting noise. In this study, the effect of surface shape and pattern of noise barriers on the reduction of reflecting noise was analyzed to maximize the noise reduction. According to the number of shape and pattern, it was observed that there were noise reduction effect as of 0.9~1.5 dB(A). It was found that the spatial field where the noise concentrates or disperses changes according to the width of blocks on the barriers as well. It suggests that there might be possibility of surface shape modification to optimize the noise reduction technology.

Analysis of Spatial Crime Pattern and Place Occurrence Characteristics for Building a Safe City (안전도시 조성을 위한 범죄의 공간적 분포와 도시의 장소별 발생특성 분석)

  • Heo, Sun-Young;Moon, Tae-Heon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.4
    • /
    • pp.78-89
    • /
    • 2012
  • The purpose of this study is to examine the possibility of crime prevention in consideration of urban physical environment by analyzing the spatial distribution characteristics and pattern using actual crime occurrence data of the case city. The crime data was rebuilt by transforming them into geographic information system to analyze the spatial aspect of crime occurrence. The findings are as follows: a change from 2008 to 2011 is indicated with similar trend. But the local movements of crime hot spots are found. Moreover crimes were happening along the roads in linear pattern rather than inside of blocks in commercial area. This indicates the importance of environmental improvement of roads and open spaces. In addition it was found that the crime occurrence in a dangerous district can be reduced and prevented through the physical environment design and urban planning. The findings will contribute to promoting fundamental crime prevention as the physical environmental improvement in a city and to building a safe community as its result.

An Ultrasonic Vessel-Pattern Imaging Algorithm with Low Computational Complexity (낮은 연산 복잡도를 지니는 초음파 혈관 패턴 영상 알고리즘)

  • Um, Ji-Yong
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.27-35
    • /
    • 2022
  • This paper proposes an ultrasound vessel-pattern imaging algorithm with low computational complexity. The proposed imaging algorithm reconstructs blood-vessel patterns by only detecting blood flow, and can be applied to a real-time signal processing hardware that extracts an ultrasonic finger-vessel pattern. Unlike a blood-flow imaging mode of typical ultrasound medical imaging device, the proposed imaging algorithm only reconstructs a presence of blood flow as an image. That is, since the proposed algorithm does not use an I/Q demodulation and detects a presence of blood flow by accumulating an absolute value of the clutter-filter output, a structure of the algorithm is relatively simple. To verify a complexity of the proposed algorithm, a simulation model for finger vessel was implemented using Field-II program. Through the behavioral simulation, it was confirmed that the processing time of the proposed algorithm is around 54 times less than that of the typical color-flow mode. Considering the required main building blocks and the amount of computation, the proposed algorithm is simple to implement in hardware such as an FPGA and an ASIC.

Analysis of Radiation Field and Block Pattern for Optimal Size in Multileaf Collimator (치료조사면 및 블록 유형분석을 통한 적정 다엽 콜리메이터 규모에 관한 연구)

  • Ahn, Seoung-Do;Yang, Kwang-Mo;Yi, Byong-Yong;Choi, Eun-Kyong;Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.253-262
    • /
    • 1994
  • The patterns of the conventional radiation treatment fields and their shielding blocks are analysed to determine the optimal dimension of the MultiLeaf Collimator (MLC) which is considered as an essential tool for conformal therapy. Total 1109 radiation fields from 303 patients (203 from Asan Medical center, 50 from Baek Hosp and 50 from Hanyang Univ. Hosp.) were analysed for this study. Weighted case selection treatment site (from The Korean Society of Therapeutic Radiology 1993). Ninety one percent of total fields have shielding blocks. Y axis is defined as leaf movement direction and it is assumed that MLC is installed on the cranial-caudal direction. The length of X axis were distributed from 4cm to 40cm (less than 21cm for $95\%$ of cases), and Y axis from 5cm to 38cm (less than 22cm for $95\%$ of cases). The shielding blocks extended to less than 6cm from center of the field for $95\%$ of the cases. Start length for ninety five percent of block is less than 10cm for X axis and 11cm for Y axis. Seventy six percent of shielding blocks could be placed by either X or Y axis direction, $7.9\%$ only by Y axis, $5.1\%$ only by X axis and It is reasonable to install MLC for Y direction. Ninety five percent of patients can be treated with coplanar rotation therapy without changing the collimator angle. Eleven percent of cases of cases were impossible to replace with MLC. Futher study of shielding technique is needed for $11\%$ impossible cases. The treatment field dimension of MLC should be larger than $21cm{\times}22cm$. The MLC should be designed as a pair of 21 leaves with 1cm wide for an acceptable resolution and 17cm long to enable the leaf to overtravel at least 6cm from the treatment field center.

  • PDF

Simulating three dimensional wave run-up over breakwaters covered by antifer units

  • Najafi-Jilani, A.;Niri, M. Zakiri;Naderi, Nader
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.297-306
    • /
    • 2014
  • The paper presents the numerical analysis of wave run-up over rubble-mound breakwaters covered by antifer units using a technique integrating Computer-Aided Design (CAD) and Computational Fluid Dynamics (CFD) software. Direct application of Navier-Stokes equations within armour blocks, is used to provide a more reliable approach to simulate wave run-up over breakwaters. A well-tested Reynolds-averaged Navier-Stokes (RANS) Volume of Fluid (VOF) code (Flow-3D) was adopted for CFD computations. The computed results were compared with experimental data to check the validity of the model. Numerical results showed that the direct three dimensional (3D) simulation method can deliver accurate results for wave run-up over rubble mound breakwaters. The results showed that the placement pattern of antifer units had a great impact on values of wave run-up so that by changing the placement pattern from regular to double pyramid can reduce the wave run-up by approximately 30%. Analysis was done to investigate the influences of surface roughness, energy dissipation in the pores of the armour layer and reduced wave run-up due to inflow into the armour and stone layer.

An Analysis of The Preferred Ease of Torso Sloper by Body Size (신체크기에 따른 토르소원형의 부위별 선호여유량 분석)

  • Kang, Yeo-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.1
    • /
    • pp.112-125
    • /
    • 2012
  • This study researches the preferred ease of torso sloper according to body sizes and drop. For this, the eases of main body parts such as chest circumference, waist circumference, hip circumference, biacromion length, and waist back length were analysed; in addition, the drop differences of body and pattern were explored to find out characteristics of silhouette changes. The subjects were 55 women in their early 20s (aged from 20 to 24) and individual torso block made with muslin was corrected 1-3 times by a personal fitting. There were 3 meaningful results. First, the preferred ease were individually various; however, the eases of all torso blocks should be same at the pattern making step. Second, the eases were also significantly different among body size groups and the bigger group preferred less ease at the biacromion length, waist back length, armhole-depth, chest circumference, and waist circumference. Third, the eases of chest circumference and hip circumference were significantly changed among drop groups. To change their body drop, H-shape drop adopted less ease at chest circumference and more ease at hip circumference; however, A-shape drop adopted more ease at chest circumference and less ease at hip circumference.

Shear Bond Strength of Zirconia and Ceramics according to Dental Zirconia Surface Treatment (치과용 지르코니아 표면처리방법에 따른 지르코니아와 전장용 도재의 결합강도 관찰)

  • Lee, Gwang-Young;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • Purpose: The dental CAD / CAM system has been popular with the development of the digital dental industry. Zirconia is a typical material in dental CAD / CAM systems. Zirconia crowns are classified into single layer and double layer. This study is about the double layer crown of zirconia. The surface roughness, bond strength and fracture patterns of the zirconia surface were observed. Methods: Zirconia blocks were cut using a low speed cutter. Sintered to form a plate shape (6mm × 6mm × 3mm). The prepared specimens were surface treated in four ways. Surface roughness and bond strength were measured. And the fracture pattern was observed. Results: Result of surface treatment of zirconia. The surface roughness test results were as ET 2.87 ㎛, ST 2.67 ㎛, LT 2.44 ㎛, AT 2.41 ㎛, CN 2.08 ㎛ order. Bond Strength results were as LT 25.09 MPa, AT 23.27 MPa, ST 21.27 MPa, ET 21.09 MPa, CN 16.12 MPa order. Fracture patterns showed cohesive failure of 25-50% of the bond area. Conclusion: Surface roughness, bond strength and fracture pattern of the zirconia surface were observed. Etching the surface treatment of zirconia materials has been shown to affect the surface roughness. Zirconia special binder treatment has been shown to affect the bond strength improvement.

Template Check and Block Matching Method for Automatic Defects Detection of the Back Light Unit (도광판의 자동결함검출을 위한 템플릿 검사와 블록 매칭 방법)

  • Han Chang-Ho;Cho Sang-Hee;Oh Choon-Suk;Ryu Young-Kee
    • The KIPS Transactions:PartB
    • /
    • v.13B no.4 s.107
    • /
    • pp.377-382
    • /
    • 2006
  • In this paper, two methods based on the use of morphology and pattern matching prior to detect classified defects automatically on the back light unit which is a part of display equipments are proposed. One is the template check method which detects small size defects by using closing and opening method, and the other is the block matching method which detects big size defects by comparing with four regions of uniform blocks. The TC algorithm also can detect defects on the non-uniform pattern of BLU by using revised Otsu method. The proposed method has been implemented on the automatic defect detection system we developed and has been tested image data of BLU captured by the system.

A Cache Managing Strategy for Fast Media Data Access (미디어 데이터의 빠른 참조를 위한 캐시 운영 전략)

  • Moon, Hyun-Ju;Kim, Suk-il
    • The KIPS Transactions:PartA
    • /
    • v.11A no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Multimedia data processing in streaming pattern contains high spatial locality and low temporal locality. This paper has proposed a dynamic data prefetching scheme that fully exploits the regularity between memory addresses referred consecutively. Compared to the existing data Prefetching scheme, the Proposed scheme can reduce data Prefetching error when an application divides an way into smaller blocks and processes them block by block. Experimental results on various media benchmark programs show the proposed scheme predicts memory addresses more accurately and results in better performance than existing prefetching schemes.

[ $PLC-{\gamma}1$ ] for Differentiating Adenocarcinoma from Reactive Mesothelial Cells in Effusions (체강 삼출액의 진단에 있어서 $PLC-{\gamma}1$ 면역 염색의 유용성)

  • Woo, Yeong-Ju;Kim, Sung-Sook
    • The Korean Journal of Cytopathology
    • /
    • v.8 no.2
    • /
    • pp.115-119
    • /
    • 1997
  • Cytologic diagnosis of reactive or malignant effusion is sometimes difficult. Especially, differentiation of benign reactive mesothelial cells from malignant cells in body effusion is more difficult. Recently, immunohistochemistry has been used to diagnose difficult cases. Phospholipase $C(PLC)-{\gamma}1$ is one of the isoenzyme of the PLC which plays central role in signal transduction involving cellular growth, differentiation and transformation by phosphorylating many protein component. Increased expression of $PLC-{\gamma}1$ in human breast carcinoma, colorectal carcinoma and stomach cancers are reported. To evaluate the efficacy of positive $PLC-{\gamma}1$ immunostaining in the diagnosis of malignancy in effusions, paraffin-embedded cell blocks of pleural fluid and ascites from 10 patients(5 metastatic adenocarcinomas, and 5 reactive mesothelial cells) were immunostained with a monoclonal antibody to $PLC-{\gamma}1$. $PLC-{\gamma}1$ immuostained all the adenocarcinomas in cell block(5/5) with intense membrane pattern, however, none of the reactive mesothelial proliferations stained with the diagnostic membrane pattern. Thus, our study strongly supports the conclusion that $PLC-{\gamma}1$ immunopositivity is likely to become a useful adjunct for the diagnosis of malignancy in effusions.

  • PDF