• Title/Summary/Keyword: partial power

Search Result 1,372, Processing Time 0.037 seconds

BOUNDED PARTIAL QUOTIENTS OF SOME CUBIC POWER SERIES WITH BINARY COEFFICIENTS

  • Ayadi, Khalil;Beldi, Salah;Lee, Kwankyu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.53 no.4
    • /
    • pp.1005-1015
    • /
    • 2016
  • It is a surprising but now well-known fact that there exist algebraic power series of degree higher than two with partial quotients of bounded degrees in their continued fraction expansions, while there is no single algebraic real number known with bounded partial quotients. However, it seems that these special algebraic power series are quite rare and it is hard to determine their continued fraction expansions explicitly. To the short list of known examples, we add a new family of cubic power series with bounded partial quotients.

Comparison of The Attenuation Measurement Methods for Electromagnetic Partial Discharge Signal in 25.8 kV Gas Insulated Switchgear (25.8 kV GIS에서 전자기파 부분방전신호 감쇠특성 측정방법 비교)

  • Goo, Sun-Geun;Han, Ki-Sun;Kwak, Joo-Sik;Joo, Hyung-Jun;Jeong, Moon-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1281-1287
    • /
    • 2015
  • We report the characteristics and differences of two types of attenuation measurement methods for electromagnetic partial discharge signal in GIS. The pulse method is to measure the attenuated waveforms in time domain and coverts them into frequency domain to get the attenuation spectra of given GIS section. This method simulates the real partial discharge signal. The frequency swept continuous wave method can obtain attenuation spectra directly so that it gives attenuation with low noise floor and simplicity. We show that both methods are effective and exchangeable because the attenuation results measured by two methods have similar trends

Partial Shift Mapping for PAPR Reduction with Low Complexity in OFDM Systems

  • Ouyang, Xing;Jin, Jiyu;Jin, Guiyue;Wang, Zhisen
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.268-271
    • /
    • 2012
  • The high peak-to-average power is one of the main drawbacks in OFDM systems. This letter proposes a partial shift mapping (PSM) method for peak power reduction in OFDM systems. By utilizing the properties of the discrete Fourier transform, the proposed method generates a set of candidate signals without additional complex multiplication and selects the one with minimum peak power for transmission. Analyses and simulations confirm that the PSM method achieves satisfactory peak power reduction performance and low complexity compared with other kindred methods, for example, selected mapping and partial transmit sequences.

Improved Model for Maximum Power Point Tracking (MPPT) of Solar System (태양광 시스템의 최대 전력지점 추적(MPPT) 정확도 향상을 위한 모델링)

  • Lee, YoungHyun;Lee, Jonghwan
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.114-118
    • /
    • 2022
  • The photovoltaic system is affected by various conditions such as temperature and irradiance. Because non-uniform irradiation and partial shading conditions affect the entire string of cells connected in series, a bypass diode is used to bypass the current flow normally. In order to find the maximum power point in partial shade conditions, it is necessary to estimate various methods of maximum power point tracking. In this paper, the hybrid method of MPPT using Lambert W function and perturbation & observation algorithm is proposed under partial shading conditions. The simulation results are obtained using MATLAB/Simulink and shows the improvement of the accuracy of MPPT.

Improved Global Maximum Power Point Tracking Technique Using Output Characteristics of Solar Array (태양광 어레이의 출력 특성을 이용한 개선된 전역 최대전력 점 추종 기법)

  • Yoo, Koo-Hyun;Lee, Woo-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2020
  • The photovoltaic module has the characteristic that the output power varies according to the amount of insolation. If partial shading occurs in an environment composed of an array, a number of local maximum power points (LMPPs) may be generated according to the shading state. Photovoltaic arrays require global maximum power point tracking due to variations in output characteristics caused by solar radiation and temperature. Conventional algorithms, such as P&O and Incond, do not follow the global maximum power point in a partial shaded solar array. In this study, we propose a technique to follow the global maximum power point by using the correlation of voltage, current, and power in solar arrays. The proposed control technique 2qw validated through simulation and experiments by constructing a 2-kW solar system.

Detection and localization of partial discharge in high-voltage direct current cables using a high-frequency current transformer (HFCT를 활용한 고전압직류송전 케이블 부분방전 위치추정)

  • Hong, Seonmin;Son, Wooyoung;Cheon, Hyewon;Kang, Daekyoung;Park, Jonghoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.105-108
    • /
    • 2021
  • Detection and localization of partial discharge are considered critical techniques for estimating the lifetimes of power cables. High-frequency current transformers (HFCTs) are commonly used for the detection of partial discharge in high-voltage alternating current (HVAC) power cables; however, their applicability is compromised by the limitations of the installation locations. HFCTs are typically installed in cable terminals or insulation joint boxes because HVACs induce strong time-varying magnetic fields around the cables, saturating the ferromagnetic materials in the HFCTs. Therefore, partial discharges near the installation locations can be detected. In this study, the feasibility of partial discharge detection using a HFCT was investigated for high-voltage direct current (HVDC) cables. We demonstrated that the HFCT could be installed at any location in the HVDC power cable to monitor partial discharge along the entire cable length. Furthermore, we showed that the HFCT could detect the location of partial discharge with high accuracy.

High Power Factor and High Efficiency DC-DC Converter using Single-Pulse Soft-Switching (단일 펄스 소프트 스위칭을 이용한 고역률 고효율 DC-DC 컨버터)

  • Jung, S.H.;Kwon, S.K.;Suh, K.Y.;Lee, H.W.;Gac, D.K.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1148-1150
    • /
    • 2003
  • Power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. However, the switches of converter are subjected to high switching power losses and switching stresses. As a result of those, the power system brings on a low efficiency. To improved these, a large number of soft switching topologies included a resonant circuit has been prosed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose a high power factor and high efficiency DC-DC converter using single-pulse soft switching by partial resonant switching node. The switching devices in a prosed circuit are operated with soft switching by the partial resonant method, that is, Partial Resonant Switch Mode Power Converter. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. Also the proposed converter is deemed the most suitable for high power applications where the power switching devices are used. Some simulative results on computer results are included to confirm the validity of the analytical results.

  • PDF

Enhanced Global Maximum Power Point Tracking Method for a Photovoltaic System (태양광 발전 시스템의 향상된 전역 최대 발전전력 추종 기법)

  • Jang, Yohan;Bae, Sungwoo;Choung, Seunghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.200-205
    • /
    • 2022
  • This paper presents an improved maximum power point tracking method that can fast track the global maximum power point (GMPP) for a photovoltaic system under partial shading conditions. The proposed method combines the advantages of the maximum power trapezium (MPT) method and the search-skip-judge method to minimize the tracking voltage intervals. Thus, the proposed method can quickly track the GMPP by skipping unnecessary tracking voltage intervals. The superiority of the proposed method is verified through simulation results in the MATLAB/Simulink and experimental real-time operation results with the hardware-in-the-loop simulation. The simulation and experimental results demonstrated that the proposed method has a faster tracking time than the MPT method under various partial shading conditions.

The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable (초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용)

  • Lee, Yong-Sung;Yang, Jong-Kyung;Yang, Jong-Keok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

ANALYTIC TREATMENT FOR GENERALIZED (m + 1)-DIMENSIONAL PARTIAL DIFFERENTIAL EQUATIONS

  • AZ-ZO'BI, EMAD A.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.22 no.4
    • /
    • pp.289-294
    • /
    • 2018
  • In this work, a recently developed semi-analytic technique, so called the residual power series method, is generalized to process higher-dimensional linear and nonlinear partial differential equations. The solutions obtained takes a form of an infinite power series which can, in turn, be expressed in a closed exact form. The results reveal that the proposed generalization is very effective, convenient and simple. This is achieved by handling the (m+1)-dimensional Burgers equation.