• Title/Summary/Keyword: panel joint

Search Result 199, Processing Time 0.031 seconds

A Study on the Rehabilitation Equipment for Knee Joint (무릎관절 재활기구에 관한 연구)

  • Lee, Gui-Hyung;Kim, Yong-Jin;Park, Seok-Hyun;Lee, Hyo-Sung;Cho, Hyun-A
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3_1spc
    • /
    • pp.509-517
    • /
    • 2013
  • This paper presents upgraded equipment to assist a patient in rehabilitating of their knee-joint by themselves. A new automatic mechanism is suggested and developed in order to add functions for enforcing the leg muscles, which were absent in previous rehabilitation machines. Using the Pro-engineer software, we analyze the displacements and speeds of several moving points of the equipment during various planned exercises. In addition, an appropriate control panel for operation is developed. Three motors andthree motor drivers are used in a tilting part for the ankle joint, sliding guide part for the knee joint, and up-down moving part for the whole leg. Finally, various newly upgraded motions can be generated by controlling the three motors simultaneously. we show that by using this equipment, we can adjust the proper length of the equipment according to the user's height and the intensity of the rehabilitation exercise.

Behavior of Steel Beam-High Strength Concrete Column Joint Subjected to Cyclic Loadings (철골보-고강도 콘크리트 기둥 접합부의 거동에 관한 연구)

  • Shin, Sung-Woo;Lee, Kwang-Soo;Seo, Seon-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.3
    • /
    • pp.205-210
    • /
    • 2000
  • The objective of this study is to investigate the structural behavior of steel beam-high strength concrete column joints subjected to reversed cyclic loadings. The variables of the experimental study is amount of steel plates at the beam-to-column joint panel zone. Three specimens were prepared and tested under constant uniaxial load($0.2f_{ck}A_g$) to reinforced high strength concrete column, and the reversed cyclic loads were applied to end of steel beams, The failure modes, hysteresis loop, stiffness degradations and energy dissipation capacities were analyzed and compared for test variables.

  • PDF

Cyclic behavior of interior beam-column connections in non-seismic RC frames at different loading rates

  • Dhakal, Rajesh P.;Pan, Tso-Chien
    • Structural Engineering and Mechanics
    • /
    • v.23 no.2
    • /
    • pp.129-145
    • /
    • 2006
  • This paper provides an insight into the response of non-seismic reinforced concrete (RC) building frames to excitations of different frequencies through experimental investigation. The results of cyclic loading tests of six full-scale RC beam-column sub-assemblies are presented. The tested specimens did not have any transverse reinforcement inside the joint core, and they were subjected to quasi-static and dynamic loading with frequencies as high as 20 Hz. Some important differences between the cyclic responses of non-seismic and ductile RC frames are highlighted. The effect of excitation frequency on the behavior of non-seismic joints is also discussed. In the quasi-static tests, shear deformation of the joint panel accounted for more than 50% of the applied story drift. The test results also showed that higher-frequency excitations are less detrimental than quasi-static cyclic loads, and non-seismic frames can withstand a higher load and a larger deformation when they are applied faster.

A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay (전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구)

  • Kim, Yong-Kyu;Kwak, Dong-Kurl;Lee, Seung-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

Construction Method for Forming Concrete Shear Keys at Vertical Construction Joints of Slurry Walls (지하연속벽 수직시공이음부에 콘크리트 전단키를 형성하는 시공기술)

  • Lee, Jeong-Young;Kim, Seung-Weon;Kim, Doo-Kie
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.401-402
    • /
    • 2023
  • The shear connection of the vertical construction joint of a slurry wall by the concrete shear key has excellent structural performance and is economical and eco-friendly. However, technology for forming concrete shear keys in the underground is still underdeveloped. This paper proposes the development of the construction technology required to form a concrete shear key at the vertical construction joint of the slurry wall.

  • PDF

An Application of Dynamic Loading Test of Precast Module Concrete Decks (프리캐스트 모듈 바닥의 동하중 재하시험)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.73-80
    • /
    • 2017
  • In this study, the panel joint behavior by the vehicle load moving on precast panel is analyzed. The frame was made for loading and the behavior was determined by using each measuring device. The static response of the panel was examined and compared with the theoretical value, and it was found that the characteristics were very reasonable. In addition, acceleration, velocity, and displacement were measured for dynamic impact evaluation, and the characteristics of moving load were analyzed in the test. The vibration frequency of the panel was measured for the dynamic response by the moving load, and the vibration characteristic was considered to be sensitive to the range of the load. As a result, it is considered that the dynamic response of the connection part should be careful in design because the characteristics are different according to the connection method.

Early-Age Performance of Intersection Pavement Constructed Using Precast Concrete Panels (프리캐스트 패널을 이용한 교차로 구간 도로 포장 초기 공용성 분석)

  • Oh, Han-Jin;Hwang, Ju-Hwan;Kim, Seong-Min;Rhee, Suk-Keun;Park, Sung-Ki
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.115-123
    • /
    • 2011
  • This study was conducted to investigate the early-age behavior and performance of precast pavements constructed by replacing existing asphalt pavements for an intersection in urban bus only lanes. The monitoring items included level differences between asphalt pavement and precast panels at the beginning and ending locations of the precast pavement, level differences and joint widths between precast panels, precast panel settlement, and skid resistance of the panel surface. At a certain time after the construction, the diamond grinding method was applied and its effect was also investigated. The monitoring results showed that as time went by, the panel level, joint width, settlement, and skid resistance were not much varied. That implied the stable sustaining of external loads by the precast pavements. In addition, it was verified that employing diamond grinding could reduce the level differences between precast panels.

Strength of PSC Bridge Decks using Half-Depth Precast Panel with Loop Joint (루프이음 반단면 프리캐스트 패널을 이용한 PSC 바닥판의 강도평가)

  • Chung, Chul Hun;Kim, Yu Seok;Hyun, Byung Hak;Kim, In Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.433-445
    • /
    • 2009
  • The panels are used as a composite part of the completed deck. They replace the main bottom transverse deck reinforcement and also serve as a form surface for the cast-in-place concrete upper layer that contains the top of deck reinforcement. Research has also demonstrated that mechanical shear ties on the top of the panels are required. In a composite deck with precast panels, it is required to notice behavior of transverse joints between panels. In this paper, static tests of composite deck with shear ties and loop joints were conducted. From the results, the validity of loop joints for continuity of deck was observed. Also, a composite behavior was abserved between precast panel and slab concrete. Tested composite decks with shear ties have 140~164% ultimate strength than have no shear ties due to the increase of composite action. Therefore, the shear ties between the slabs were sufficient to enforce composite flexural behavior to failure.

Fatigue Performance of Bridge Decks using Half-Depth Precast Panel with Loop Joint (루프이음 반단면 프리캐스트 패널을 이용한 교량 바닥판의 피로성능)

  • Chung, Chul Hun;Lim, Seung Jun;Kim, Hyun Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.35-43
    • /
    • 2010
  • The panels are used as a composite part of the completed deck. They replace the main bottom transverse deck reinforcement and also serve as a form surface for the cast-in-place concrete upper layer that contains the top of deck reinforcement. However, in order to apply the precast panels to bridges properly, it is necessary to fully understand the structural characteristics of joint in precast panels. Particularly, since the bridge deck is under repeated loads such as traffic loads, fatigue behavior and characteristics of joint should be investigated. In this paper, fatigue tests of composite deck with shear ties and loop joints were conducted. The fatigue tests were conducted with an application of repeated loading and wheel loading. Test results were analyzed to examine the current design code for fatigue of reinforcement bar and serviceability under repeated loading.

Discrete Optimum Design of Steel Framed Structures Subjected to Deformed of Panel Zone (패널영역의 변형을 고려한 강뼈대 구조물의 이산화 최적설계)

  • 박순응;박문호;권민호;장준호
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.315-327
    • /
    • 2002
  • The main objective of this study is to develop an discrete optimization algorithm of plane steel frames with rigid using second-order-elastic-plastic hinge analysis which is considering panel zone. Conventional analyses of steel frame are usually tarried out without considering the effect of panel zone deformation on frame behavior The validity of this model is established by comparison without panel zone on joint models is analyzed numerically to demonstrate the importance of using realistic models in steel frame analysis. The objective function is taken as Weight of steel frames and the constraints we formulated based on AISC-LRFD(1994). The validity of the developed algorithm we demonstrate by comparing the result with those of SAP2000. The result of the study indicates that the optimal design algorithm considering of panel zone behavior more economic design than simple steel frame design methods.