• Title/Summary/Keyword: paddle

Search Result 167, Processing Time 0.032 seconds

The effects of monitoring of the pressures applied on the defibrillator paddles - A manikin study - (제세동 패들에 가해지는 압력의 모니터링 효과)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.9-18
    • /
    • 2012
  • Purpose : The purpose of this study was to determine the changes that occur due to the real-time monitoring of paddle pressures which has an important influence on the defibrillation success rate in defibrillation treatment known as the only treatment for cardiac arrest patients with VF. Methods : 40 people participated in the cardiac arrest simulation training and played the role of the defibrillation operator. Investigators measured the pressure of paddle while defibrillating by using instrument which was developed by the investigator. Results : Through real-time monitoring of the paddle pressures of defibrillator by indicator, the front sternum paddle showed a 77.5% success rate and the apex paddle showed a 40% success rate. While the values without monitoring the paddle pressures, the front sternum paddle showed a 51% success rate and the apex paddle showed a 20% success rate. These experiment revealed statistically significant(p <.001) low success rate. Conclusion : The method of monitoring the paddle pressures during defibrillation showed that the paddle can be precisely gripped. The success rate of paddle pressures is significantly correlated with height, weight and grip strength.

Design and Implementation of Paddle Type End of Arm Tool for Rescue Robot (인명 구조용 로봇의 패들형 말단 장치 설계 및 구현)

  • Kim, Hyeonjung;Lee, Ikho;An, Jinung
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.4
    • /
    • pp.205-212
    • /
    • 2018
  • This paper deals with the paddle type end of arm tool for rescue robot instead of rescue worker in dangerous environments such as fire, earthquake, national disaster and defense. It is equipped at the dual arm manipulator of the rescue robot to safely lift up an injured person. It consists of the paddle for lifting person, sensors for detecting insertion of person onto the paddle, sensor for measuring the tilting angle of the paddle, and mechanical compliance part for preventing incidental injuries. The electronics is comprised of the DAQ module to acquire the sensors data, the control module to treat the sensors data and to manage the errors, and the communication module to transmit the sensors data. After optimally designing the mechanical and electronical parts, we successfully made the paddle type end of arm tool and evaluated its performance by using specially designed jigs. The developed paddle type end of arm tool is going to be applied to the rescue robot for performance verification through field testing.

Effects of Paddle Wheel on Water Circulation in Shrimp Culture Ponds (축제식 대하양식장에서 수차의 순환기능)

  • 강윤호
    • Journal of Aquaculture
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2001
  • To study the effect of paddle wheel on water circulation, velocity components were measured in shrimp ponds both along the longitudinal direction from a single paddle wheel and at 25 grid points of two ponds, which have mean water depth of 1.2m and aspect ratio (length/width) 1.05 and 0.68, respectively. An analysis of factors related to water quality and circulation showed that I) a single paddle wheel has an effective distance of 33m for de-stratification, 16m for particulate suspension and 25m for removal of organic material, dispersion of DO and prevention of bed sediment disturbance and ii) with doubling the number of paddle wheels at the pond corners, the flow speed increased by 13% over the ponds, while it reduced by 8.5% around the pond centres. Contrary to expectation, increasing the number of paddle wheel did not generate strong circulation around the pond centre and improve water quality.

  • PDF

TRANSIENT FLOW SIMULATION OF A MIXER WITH FREE SURFACE (자유표면을 고려한 교반기 내부의 비정상 유동해석)

  • Ahn, Ick-Jin;Song, Ae-Kyung;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • v.11 no.4 s.35
    • /
    • pp.9-13
    • /
    • 2006
  • In the present study, a numerical analysis of transient mixer flow is performed considering free surface formation. The flow patterns and free surface shape in a mixers formed by flat paddle and pitched paddle impellers are predicted. In a flat paddle mixer, two flow circulation regions are formed due to strong radial flow, whereas one large circulation is formed in a pitched paddle mixer due to axial downward flow. These differences affect the free surface evolution and shape. It is seen from the results that a flat paddle mixer gives deeper free surface at center region than a pitched paddle mixer. The free surface of 8-blades-flat-paddle mixer is also simulated to compare with the available experimental and simulation results. The present computational results agree reasonably well with the experimental data.

Effect of a Reciprocating Paddle on the Electrodeposit Uniformity of Patterned Cathodes (왕복패들이 패턴화된 음극의 전착균일성에 미치는 영향)

  • Oh Young-joo;Chung Soon-hyo
    • Korean Journal of Materials Research
    • /
    • v.14 no.3
    • /
    • pp.196-202
    • /
    • 2004
  • A numerical simulation based on the finite element method is used to investigate the effect of a reciprocal paddle on the uniformity of deposition rates at a patterned electrode. The calculated deposition rates agreed well with the measured values. The influences of the paddle velocity, the gap between cathodes and paddles, anode size and the distance between the anode and cathode have been studied. The optimum conditions on the paddle and geometric factors for electrodeposit uniformity could be obtained.

Paddling Posture Correction System Using IMU Sensors

  • Kim, Kyungjin;Park, Chan Won
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2018
  • In recent times, motion capture technology using inertial measurement unit (IMU) sensors has been actively used in sports. In this study, we developed a canoe paddle, installed with an IMU and a water level sensor, as a system tool for training and calibration purposes in water sports. The hardware was fabricated to control an attitude heading reference system (AHRS) module, a water level sensor, a communication module, and a wireless charging circuit. We also developed an application program for the mobile device that processes paddling motion data from the paddling operation and also visualizes it. An AHRS module with acceleration, gyro, and geomagnetic sensors each having three axes, and a resistive water level sensor that senses the immersion depth in the water of the paddle represented the paddle motion. The motion data transmitted from the paddle device is internally decoded and classified by the application program in the mobile device to perform visualization and to operate functions of the mobile training/correction system. To conclude, we tried to provide mobile knowledge service through paddle sport data using this technique. The developed system works reasonably well to be used as a basic training and posture correction tool for paddle sports; the transmission delay time of the sensor system is measured within 90 ms, and it shows that there is no complication in its practical usage.

Skin Paddle Salvage in Atypical Fibula Osteocutaneous Free Flap with Peroneal Flow through Vascular Anastomosis (후 경골 동맥에서 분지한 비 특이성 비골 골피 유리 피판에서의 관통 혈류 미세 문합을 통한 피부판의 구제)

  • Kim, Min Soo;Lew, Daei Hyun;Lee, Won Jai;Tark, Kwan Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.24-28
    • /
    • 2004
  • The vascularity of a skin island in fibula osteocutaneous free flap often depends on musculocutaneous perforators that find their origin in the proximal peroneal artery. But a potential drawback has been reported on the unreliability of the skin paddle. The perforating vessels to the skin paddle of the fibula osteocutaneous free flap were rarely derived from a common tibio-fibula trunk, an anterior tibial artery and a posterior tibial artery. Previous studies have emphasized total loss of the overlying skin paddle, if the expected perforating vessels are not present. We report here on our experience that the skin paddle of the fibula osteocutaneous free flap was vascularized not by a peroneal artery but a direct branch of the posterior tibial artery. There were no intraseptal nor intramuscular pedicles in the posterior crural septum which connected to the overlying skin island. Therefore, we performed microsurgical anastomoses between distal peroneal vessels of the fibula and the perforating branches of the posterior tibial vessels of the skin paddle. The anastomosed skin paddle was salvaged with a peroneal flow through vascular anastomosis and was transferred to the bone and intraoral soft tissue defects with the fibula graft. The patient had no evidence of vascular compromise in the postoperative period and showed good healing of the intraoral skin flap.

  • PDF

A Structural Design and Manufacture of Paddle type Small-scaled Composite Blade for Hingeless Rotor System of Helicopter (헬리콥터 힌지없는 로터 시스템용 패들형 축소 복합재료 블레이드 구조 설계 및 제작)

  • Kim, Deog-Kwan;Hong, Dan-Bi;Lee, Myung-Kyu;Joo, Gene
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.220-223
    • /
    • 2002
  • This paper introduces the development procedure of paddle type small-scaled composite rotor blade for helicopter hingeless rotor system. Paddle type composite blade design was done by using CORDAS program developed by KARI and dynamic analysis for hingeless hub with blade is done by using FLIGHTLAB which is commercial software for helicopter comprehensive analysis. The procedure to manufacture complicated shape of paddle type blade tip was developed and composite blades were manufactured after establishing the effective curing method. Through this research, the development technology of composite rotor blade with complex aerodynamic shape were accumulated and these will be applied to the related research field, for example, full size composite blade development, etc.

  • PDF

A Study of Wire Sweep, Pre-conditioning and Paddle Shift during Encapsulation of Semiconductor Chips (반도체 칩 캡슐화 성형 공정에 있어서 와이어 스윕 및 패들 변형에 관한 연구)

  • Han, Se-Jin;Heo, Yong-Jeong;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.102-110
    • /
    • 2001
  • In this paper, methods to analyze wire sweep and paddle shift during the semiconductor ship-encapsulation process have been studied. The analysis of wire sweep includes flow-field analysis in a complicated geometry, drag-force calculation for given flow of fluid, and wire-deformation calculation for given loads. The paddle-shift analysis is used to analyze the deformation of the paddle due to the pressure difference in two cavities. the analysis is done using either analytical solutions or numerical simulation. The analytical solution is used for rough but fast calculation of wire sweep. The numerical solution is used for more accurate calculation of wire-sweep. The numerical results of wire sweep show good agreements with the experimental ones.

  • PDF

The Changes of Defibrillation Time Depending on the Manual External Defibrillator Device (제세동 시행도구에 따른 제세동 지연시간의 변화)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • Objectives: This study is to research delay time comparison for later defibrillation after hands off according to the changes in defibrillation electrodes. Study purpose: In defibrillation treatment that is the only way for cardiac arrest by arrhythmia, it is to find defibrillator device which can minimize late defibrillation delay time after important affect of hands off. Study object and method: After hands off according to the defibrillator device, we collected total 40 people for emergency medicine doctor, internal medicine doctor, general surgeon, nurse, emergency medical technician who are working at 2 CN, CS University hospitals in Gwangju Jeollanamdo district to find out hand off shock interval(HOSI). We then researched their general properties like occupation sector, experiences in clinic, gender, completion of AHA ACLS-P training and more. Then 40 participants continued ventricular fibrillation cardiac arrest simulation training (using human-model mannequin) designed by researcher and performed their roles as defibrillation operator. Each of participant used manual paddle and performed 4 times of defibrillation (150J) during 8 minutes of CPR and in 8day, the defibrillator devices were replaced from manual paddle to self-adhesive electrodes pads and 4 times of defibrillation (150J) under same simulation condition as manual paddle were performed. Study result: In comparison for delay time of later defibrillation after hands off of manual paddle and self adhesive electrodes pad, the self adhesive electrodes pad ($7.0{\pm}0.5sec$) seemed to reduce delay time of later defibrillation significantly (p<0.05) compared to manual paddle ($10.0{\pm}0.9sec$). The self adhesive electrodes pad, according to the general properties of participants, had no particular change in delay time after later defibrillation for the statistics (p>0.05) but the manual paddle had statistically significant differences for the occupation sector, experiences in clinic and gender (p<0.05). Conclusion: In defibrillation, the self adhesive electrodes pad($7.0{\pm}0.5sec$) showed short HOSI compared to manual paddle ($10.0{\pm}0.9sec$) significantly (p<0.05) and it applied identically for both existence and non-existence of ACLS-P training completion, experiences in clinic, gender and occupation sector. The manual paddle had also significant difference in experiences in clinic and occupation sector (p<0.05). which means the effect on HOSI according to the job mastery. Therefore, if the clinic experience is short or in case for the occupations without frequent defibrillation treatment has a danger of lowering success rate for the defibrillation using manual paddle. Therefore, it is true that using self adhesive electrodes pad for defibrillation electrodes when performing manual defibrillation in pre-hospital as well as in-hospital steps can generally minimize delay time of later defibrillation after hands off.