• 제목/요약/키워드: package module

검색결과 255건 처리시간 0.029초

ERP 시스템의 문제점 분석을 통한 생산관리 프로세스 정의에 관한 연구 (A study on Production Process Definition through Problem Analysis of ERP System)

  • 남승돈;양광모;강경식
    • 대한안전경영과학회지
    • /
    • 제5권4호
    • /
    • pp.97-106
    • /
    • 2003
  • At present, tendency of ERP(Enterprise Resource Planning) enterprises is that many ERP enterprises from abroad are rushing into capture of small and medium enterprises at home actively. SAP Korea and Korean Oracle have already showed their new product targeting domestic market of small or medium standing enterprise, and more, even MS(Micro Soft) also rushes into this market in earnest. The domestic business circle of ERP should prepare countermeasure by raising the perfection of product and having good command of minute marketing strategy to survive from aggressive strategy of SMB market. In addition, about the computerization of main affairs of business, ordering developing process was general that developing staffs analysed the affairs of each department that needed computerization and construct according to the operation process by using different tools, but condition is changing that businesses themselves are purchasing business application package from expert soft program enterprise and construct. Therefore, in this study, I try to grasp the problem of management, and define a new process that can help for more efficient management by making it an object producing and management module of enterprise 'K' that is one of domestic small and medium enterprise and that is operating ERP at present. As well, through the analysis of affair related producing, we are aiming to prepare for establishment of target, its range, and making the standard of result evaluation.

A Polymer-based Capacitive Air Flow Sensor with a Readout IC and a Temperature Sensor

  • Kim, Wonhyo;Lee, Hyugman;Lee, Kook-Nyeong;Kim, Kunnyun
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2019
  • This paper presents an air flow sensor (AFS) based on a polymer thin film. This AFS primarily consists of a polymer membrane attached to a metal-patterned glass substrate and a temperature-sensing element composed of NiCr. These two components were integrated on a single glass substrate. The AFS measures changes in capacitance caused by deformation of the polymer membrane based on the air flow and simultaneously detects the temperature of the surrounding environment. A readout integrated circuit (ROIC) was also fabricated for signal processing, and an ROIC chip, 1.8 mm by 1.9 mm in size, was packaged with an AFS in the form of a system-in-package module. The total size of the AFS is 1 by 1 cm, and the diameter and thickness of the circular-shaped polymer membrane are 4 mm and $15{\mu}m$, respectively. The rate of change of the capacitance is approximately 11.2% for air flows ranging between 0 and 40 m/s.

The influence of the water ingression and melt eruption model on the MELCOR code prediction of molten corium-concrete interaction in the APR-1400 reactor cavity

  • Amidu, Muritala A.;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1508-1515
    • /
    • 2022
  • In the present study, the cavity module of the MELCOR code is used for the simulation of molten corium concrete interaction (MCCI) during the late phase of postulated large break loss of coolant (LB-LOCA) accident in the APR1400 reactor design. Using the molten corium composition data from previous MELCOR Simulation of APR1400 under LB-LOCA accident, the ex-vessel phases of the accident sequences with long-term MCCI are recalculated with stand-alone cavity package of the MELCOR code to investigate the impact of water ingression and melt eruption models which were hitherto absent in MELCOR code. Significant changes in the MCCI behaviors in terms of the heat transfer rates, amount of gases released, and maximum cavity ablation depths are observed and reported in this study. Most especially, the incorporation of these models in the new release of MELCOR code has led to the reduction of the maximum ablation depth in radial and axial directions by ~38% and ~32%, respectively. These impacts are substantial enough to change the conclusions earlier reached by researchers who had used the older versions of the MELCOR code for their studies. and it could also impact the estimated cost of the severe accident mitigation system in the APR1400 reactor.

Theoretical and experimental analysis of a venting clip to reduce stray inductance in high-power conversion applications

  • Jang, Hyun Gyu;Jung, Dong Yun;Kwon, Sungkyu;Cho, Doohyung;Park, Kun Sik;Lim, Jong-Wong
    • ETRI Journal
    • /
    • 제43권6호
    • /
    • pp.1103-1112
    • /
    • 2021
  • In this study, we present a venting clip for high-power applications that is intended to reduce stray inductance. To reduce the stray inductance of packages in high-power applications, the proposed venting clip features slots are inserted onto a conventional clip. A conventional clip and the proposed venting clip were designed and fabricated to compare the respective stray inductance. The inductance of the proposed venting clip was approximately 15.8% than that of the conventional clip at a frequency of 100 kHz. Through a comparison between the conventional and venting clips, it is confirmed that the proposed venting clip is superior for high-power applications in terms of decreasing inductance. With reduced inductance, the switching-loss for such applications is also expected to decrease. Moreover, the impedance of the venting clip decreased by approximately 15.5% compared with that of the conventional clip at a frequency of 100 kHz. The venting clip, which has reduced resistive component, is also expected to decrease conduction loss in highpower applications.

Solving the contact problem of functionally graded layers resting on a HP and pressed with a uniformly distributed load by analytical and numerical methods

  • Yaylaci, Murat;Sabano, Bahar Sengul;Ozdemir, Mehmet Emin;Birinci, Ahmet
    • Structural Engineering and Mechanics
    • /
    • 제82권3호
    • /
    • pp.401-416
    • /
    • 2022
  • The aim of this study is to examine the frictionless double receding contact problem for two functionally graded (FG) layers pressed with a uniformly distributed load and resting on a homogeneous half plane (HP) using analytical and numerical methods. The FG layers are made of a non-homogeneous material with an isotropic stress-strain law with exponentially varying properties. It is assumed that the contact at the FG layers and FG layer-HP interface is frictionless. The body force of the FG layers and homogeneous HP are ignored in the study. Firstly, an analytical solution for the contact problem has been realized using the theory of elasticity and the Fourier integral transform techniques. Then, the problem modeled and two-dimensional analysis was carried out by using the ANSYS package program based on FEM. Numerical results for contact lengths and contact pressures between FG layers and FG layer-HP were provided for various dimensionless quantities including material inhomogeneity, distributed load width, the shear module ratio, and the heights of the FG layers for both methods. The results obtained using FEM were compared with the results found using the analytical formulation. It was found that the results obtained from analytical formulation were in perfect agreement with the FEM study.

엘리베이터를 통한 층간 이동이 가능한 실내 자율주행 로봇용 센서 시스템 (Sensor System for Autonomous Mobile Robot Capable of Floor-to-floor Self-navigation by Taking On/off an Elevator)

  • 이민호;나건우;한승오
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.118-123
    • /
    • 2023
  • This study presents sensor system for autonomous mobile robot capable of floor-to-floor self-navigation. The robot was modified using the Turtlebot3 hardware platform and ROS2 (robot operating system 2). The robot utilized the Navigation2 package to estimate and calibrate the moving path acquiring a map with SLAM (simultaneous localization and mapping). For elevator boarding, ultrasonic sensor data and threshold distance are compared to determine whether the elevator door is open. The current floor information of the elevator is determined using image processing results of the ceiling-fixed camera capturing the elevator LCD (liquid crystal display)/LED (light emitting diode). To realize seamless communication at any spot in the building, the LoRa (long-range) communication module was installed on the self-navigating autonomous mobile robot to support the robot in deciding if the elevator door is open, when to get off the elevator, and how to reach at the destination.

선택적 산화 알루미늄 기판을 이용한 소형 2.5 GHz 8 W GaN HEMT 전력 증폭기 모듈 (A Miniaturized 2.5 GHz 8 W GaN HEMT Power Amplifier Module Using Selectively Anodized Aluminum Oxide Substrate)

  • 정해창;오현석;염경환
    • 한국전자파학회논문지
    • /
    • 제22권12호
    • /
    • pp.1069-1077
    • /
    • 2011
  • 본 논문에서는 선택적 산화 알루미늄(SAAO: Selectively Anodized Aluminum Oxide) 기판을 이용하여 2.5 GHz 8 W급 소형 GaN HEMT 전력 증폭기 모듈을 설계, 제작하였다. SAAO 기판 공정은 최근 Wavenics사에서 제안한 특허 기술로서, 알루미늄을 웨이퍼로 이용한다. 본 연구에 사용된 능동 소자는 최근 발표된 TriQuint사의 칩 형태 의 GaN HEMT이다. 최적의 임피던스는 수동 조정 소자가 내장된 지그를 사용하여 실험적으로 결정하였다. 결정된 임피던스를 이용하여, 입 출력 임피던스 정합 회로를 EM co-시뮬레이션을 이용하여 F급으로 설계를 수행하였으며, SAAO 기판에 구현하였다. 이때, 소형의 패키지(모듈)에 집적하기 위하여 인덕터와 커패시터는 각각 spiral inductor, single layer capacitor를 사용하였다. 소형으로($4.4{\times}4.4\;mm^2$) 패키지된 전력 증폭기 모듈의 경우, 출력은 8 W, 효율은 40 % 그리고 2차 및 3차 고조파에 대한 고조파 억제는 30 dBc 이상의 특성을 보였다.

신뢰도 기반 교량 안전성 평가를 위한 구조신뢰성 해석 플랫폼 FERUM-MIDAS의 개발 (Development of Structural Reliability Analysis Platform of FERUM-MIDAS for Reliability-Based Safety Evaluation of Bridges)

  • 이승준;이영주
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.884-891
    • /
    • 2020
  • 교량은 현대 사회에서 중요한 사회기반시설물 중에 하나로 교량의 붕괴는 막대한 인명 피해와 경제적 손실을 일으킬 수 있다. 따라서 교량의 구조적 안전성을 평가하는 것은 매우 중요하며, 이를 위해 교량을 둘러싼 여러 종류의 불확실성 요인들을 고려하는 구조신뢰성 해석이 흔히 사용된다. 본 연구에서는 다양한 하중 조건에서 교량의 안전성을 평가하기 위한 새로운 구조신뢰성 해석 플랫폼을 제안한다. 제안 플랫폼 FERUM-MIDAS는 신뢰성 해석 소프트웨어인 Finite Element Reliability Using MATLAB(FERUM)과 교량 설계/해석에 특화된 상용 소프트웨어인 MIDAS/CIVIL을 연결하여, 자동적인 입출력 데이터 교환을 통해서 구조신뢰성 해석을 수행한다. 나아가 MIDAS/CIVIL의 그래픽 사용자 인터페이스로만 소프트웨어 구동이 가능한 한계점을 극복하기 위하여 FERUM에 별도의 그래픽 사용자 인터페이스 제어 모듈을 추가하였다. 본 연구에서는 제안 플랫폼을 간단한 프레임 예제에 적용하여 대표적인 신뢰성 해석 방법인 FORM(First-Order Reliability Method)과 MCS(Monte Carlo simulation)의 해석 결과를 비교·분석하였으며, 계산된 파괴확률 차이가 5% 미만인 것을 확인하여 제안 플랫폼의 검증을 완료하였다. 이와 더불어 개발된 플랫폼을 활용하여 KL-510 활하중 모델을 고려한 프리스트레스트 콘크리트(pre-stressed concrete, PSC)교의 파괴확률과 신뢰도 지수를 도출하고, 그 결과를 분석하여 교량의 구조적 안전성을 평가하였다. 본 연구에서 제안한 새로운 구조신뢰성 해석 플랫폼을 통해 교량의 효과적인 신뢰도 기반 안전성 평가가 가능할 것으로 기대된다.

고속/고집적 ATM Switching MCM 구현을 위한 설계 Library 구축 밀 시험성 확보 (Generation of Testability on High Density /Speed ATM MCM and Its Library Build-up using BCB Thin Film Substrate)

  • 김승곤;지성근;우준환;임성완
    • 마이크로전자및패키징학회지
    • /
    • 제6권2호
    • /
    • pp.37-43
    • /
    • 1999
  • 대용량, 고속 정보처리가 요구되는 시스템의 모듈은 데이터 처리의 고속성 및 회로의 고집적이 가능한 MCM의 형태로 구현되어 ATM, GPS 및 PCS 등의 분야에 광범위하게 응용되고 있다. 3개의 칩으로 구성되고 2.48 Gbps의 데이터 처리용량을 가지는 ATM Switching 모듈을 기판 Size 48$\times$48mm2, Cu/PhotoBCB를 이용한 10 Multi-Layer 그리고 491 Pin PBGA 형태의 MCM을 개발하였다. MCM 개발을 위해 요구되는 기술로는 고속신호 특성구현을 위해 Interconnect Characterization을 통한 기판/ 패키지의 설계 파라미터 추출, 고밀도 MCM 에서의 방열처리 그리고 MCM 개발의 가장 난점중의 하나인 시험성 확보를 들 수 있다. ATM Switching MCM 개발을 위해 MCM-D 기판에서의 Interconnect Characterization을 통한 신호지연, 비아특성, 신호간섭(Cross-talk) 파라미터 등을 추출하였다. 고집적 구조에서 15.6Watt의 방열처리를 위해 열 해석을 진행하고 기판에 열 비아 1.108개를 형성하고 패키지 전체에 $85^{\circ}C$ 이하 유지조건의 방열처리를 하였다. 마지막으로 시험성 확보를 위해 미세 간격 프로빙을 통한 기판 검증 및 복잡한 패키지/어셈블리 공정검증을 위해 Boundary Scan Test(BST)를 적용하여 효과적이고 비용 절감형의 제품을 개발하였다.

  • PDF

MVA 알고리즘을 이용한 ATM 기반 통합 서비스 교환기 내 워크스테이션의 성능 평가 (Performance Evaluation of Workstation System within ATM Integrated Service Switching System using Mean Value Analysis Algorithm)

  • 장승주;김길용;이재흠;박호진
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제6권4호
    • /
    • pp.421-429
    • /
    • 2000
  • 현재 ATM(Asynchronous Transfer Mode) 기반 통합 서비스 교환 시스템 개발 추세는 복합 교환 시스템에서의 운용, 보전 기능 및 ATM 기반 인터넷/협대역 통합 서비스 등을 수용하기 위하여 워크스테이션에 멀티플러그-인 개념을 도입하여 시스템이 설계, 구현되고 있다. 한편, 기존 워크스테이션에서는 교환 시스템을 운용하기 위해 HMI(Human Machine Interface) 운용 시스템 기능과 함께 파일 관리 기능, 시간 관리 기능, 그래픽 처리 기능 및 TMN(Telecommunication Management Network)의 에이전트 기능 등이 설정되어 교환 시스템과의 많은 인터페이스를 통하여 기능들이 수행되고 있다. 이러한 기능들은 프로세스 혹은 프로세서간 많은 메시지 통신을 필요로 하고 있으며, 워크스테이션내 입출력 장치 파일, 일반 파일, 그리고 메시지 전송을 위한 메시지 큐, 소켓 자원 등을 사용하고 있다. 따라서, 현재 개발 중인 시스템의 정상 동작 여부를 확인하고 파악된 문제점들에 대한 성능 개선과 함께 추후 지속적인 기능 추가 시에도 시스템의 정상 동작을 보장하기 위해서는 사전에 개발될 교환 시스템에 대한 성능 평가가 선행되어야 한다. 본 논문은 이러한 ATM 기반 통합 서비스 교환 시스템 개발 작업에서 사전에 시스템의 성능 평가를 했다. 성능 평가는 MVA(Mean Value Analysis) 알고리즘을 이용한다. 모델은 큐잉 네트워크 모델을 사용하고 모델링된 시스템을 이용하여 PDQ(Pretty Damn Quick) 시뮬레이션 패키지와 C 언어를 사용하여 시뮬레이션 하였다.

  • PDF