• Title/Summary/Keyword: pH Sensor

Search Result 488, Processing Time 0.028 seconds

Fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water (Part I. : Design and development) (오염수 내의 유기인 화합물의 측정을 위한 광섬유 바이오센서 (제 1 부 : 장치 설계 및 개발 ))

  • Choi, Jeong-Woo;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.50-56
    • /
    • 1994
  • Fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water was developed, which was the component of pesticides and agricultural agent. The detection principle of designed sensor was the pH variance induced by a reaction of acetylcholinesterase enzyme inhibited by organophosphorus compounds. The pH variance was detected by the optical system to measure the organophosphorus compounds. Litmus was selected as the pH-sensitive dye suitable to the enzyme reaction and a light source to be detected by the optical system. The enzyme entrapped in Ca-alginate gel was immobilized at the inner wall to maintain the high activity of enzyme and to be reused for a long period. The optical fiber was used to miniaturize and control remotely the sensor system. The He-Ne laser with 632 nm was selected as the light source to prevent light intensity fluctuation by the product. Cheap plastic optical fibers were used as the transmission part of the light and the phototransistor was used as the reception part of light based on the wavelength of He-Ne laser. The proposed fiber-optic biosensor has the linear analytical range of 0 ppm-1.5 ppm with response time of 5 minutes.

  • PDF

DNA 템플릿을 활용한 전이금속 칼코겐화합물 트랜지스터 기반 바이오센서 연구

  • O, Ae-Ri;Gang, Dong-Ho;Park, Jin-Hong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.213.1-213.1
    • /
    • 2015
  • Field effect transistors (FETs)를 기반으로 한 바이오센서는 빠른 응답속도, 저비용, label-free 등을 이유로 각광받고 있다. 그러나 3D 구조를 기반으로 한 FETs 바이오센서의 낮은 sensitivity의 한계점을 지니며, 이를 극복하기 위해 1D 구조의 나노튜브 등을 활용하였으나 여전히 높은 sensitivity의 확보는 힘들다. 최근에는 이러한 문제점을 극복하기 위해 이차원 반도체 물질 중 하나인 Transition metal dichalcogenide (TMD)를 이용하여, 700 이상의 sensitivity를 지니는 pH센서 및 100 이상의 sensitivity를 지니는 바이오센서가 보고되었다. 하지만 이보다 더 높은 정확성 및 반응성을 높이기 위한 연구는 부족한 실정이다. 우리는 DNA 템플릿을 이용하여, TMD FET 기반 pH 및 바이오센서의 반응성을 극대화시키는 연구를 선보인다. DNA는 7~8정도의 유전상수 (K)를 가지는 물질로 기존 $SiO_2$(K=3.9)보다 높은 유전상수를 가지며 두께를 0.7 nm로 매우 얇게 형성할 수 있는 장점이 있다. 이는 FET 기반 바이오센서의 표면 캐패시턴스를 높여 sensitivity를 극대화할 수 있으며, 기존에 사용된 high-k 기반 바이오센서와 비교하여도 약 10배 이상의 sensitivity 향상을 노릴 수 있다. 또한, TMD 물질로 우리는 $WSe_2$를 선택하였으며, pH 용액의 receptor로써 우리는 3-Aminopropyltriethoxysilane (APTES)를 활용하였고, 템플릿으로 사용된 DNA는 DX tile 및 Ring type의 두 가지를 사용하였다. 추가로, DNA의 phosphate backbone을 중성화시키고 DNA의 base pairing의 charge 안정화를 위해 구리 이온($Cu^{2+}$) 및 란타넘족($Tb^{3+}$)을 추가하였다. 완성된 바이오센서의 pH 센싱을 위해 우리는 pH 6,7,8의 표준 용액을 사용하였으며, 재현성 및 반복성의 확인하였다.

  • PDF

Automatic Titration Using Micro pH Electrode in Volatile Basic Nitrogen Analysis (마이크로 pH전극을 이용한 휘발성염기질소의 자동적정)

  • Lee, Hyeong-Choon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.4
    • /
    • pp.507-509
    • /
    • 2006
  • An automatic titration was performed by a home-made automatic control system adopting a micro pH electrode as its sensing part in microdiffusion-based volatile basic nitrogen (VBN) analysis. The micro electrode was considered to be adequate for automatic VBN analysis because of its small sensor size, low immersion depth and unbreakable body. Six pork samples in different degree of freshness were analyzed both manually and automatically. The data from automatic titration were not significantly different from those taken by manual titration even at 15% significance level. The correlation coefficient was 1.000.

Vibration Control of a Glass-Fiber Reinforced Termoplastic Composite Beam (유리섬유를 함유한 열가소성 복합재 보의 진동제어)

  • 권대규;윤여흥;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.11-14
    • /
    • 2000
  • This paper presents the vibration control of a glass-fiber reinforced thermoplastic composite beam with a distributed PVDF sensor and piezo-ceramic achlator. The three types of different controllen which are PID, H$\infty$ , and p-synthesis ontrollcr are employed to achieve vibration suppression in the transient vibration of composite beam. In the H$\infty$ , controller design, 1st and 2nd natural frequencies are considered in the modeling, because robust control theory which has robustness to struchred uncertainty is adopled Lo suppress the vibration. If the controller designed by H$\infty$ , theory does not satisfy control performance, it is improved by $\mu$ -synthesis method with D-K iteration so that the$\mu$-contoller based on the structured singular value satisfies the nominal performance and robust performance Simulations and experiments were carried out with the designed controllers m order to demonstrate the suppression efficiency of each controller.

  • PDF

Nitrogen Isotope Labeled Tetraheme Cytochrome c3 on a Defined Medium

  • Kim, Andre;Park, Jang-Su
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.2
    • /
    • pp.278-280
    • /
    • 2005
  • To obtain cytochrome $c_3$ labeled with a stable isotope, the conditions of cultivation and the composition of medium for DvMF were examined. The growth of DvMF was steady and reproducible under purging with $N_2$ and under pH control. DvMF was able to go on a defined medium without natural products. The composition of medium containing a small amount of $NH_4C$l as sole nitrogen source was established. Then, uniformly $^{15}N$labeled cytochrome $c_3$ was obtained during the culture of DvMF in a defined medium with $^{15}NH_4$Cl; it was confirmed by $^1H-^{15}N$ HMQC.

Study of Quality Control of Traditional Wine Using IT Sensing Technology (IT 센싱 기술을 이용한 전통주 발효의 품질관리 연구)

  • Song, Hyeji;Choi, Jihee;Park, Chan-Won;Shin, Dong-Beom;Kang, Sung-Soo;Oh, Sung Hoon;Hwang, Kwontack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.904-911
    • /
    • 2015
  • The objective of this study was to investigate the quality characteristics of traditional wine using an radio-frequency identification (RFID) system annexed to a fermenter. In this study, we proposed an RFID-based data transmission scheme for monitoring fermentation of traditional alcoholic beverages. The pH, total acidity, total sugar, soluble sugar, free sugar, alcohol content, and organic acids of were investigated and subjected to fermentation of traditional alcoholic beverages three times. The pH ranged from 7.98, 7.95, and 7.68 at day 0, decreased drastically to 3.31~2.96 at day 2, and then slowly increased to the end point, finally reaching 3.34 at day 20. Acidity tended to increase quickly with time, especially for all samples after day 2. The fermentation environment induced a sudden increase acidity in reactants and indicated a low pH. The total sugars during fermentation quickly decreased to the range of 20.3, 22.43, and 19.2% at day 2, and the slope of reduction steadily decreased to 5.1, 6.1, and 4.8% at day 10. On the other hand, the alcohol content showed the reverse trend as total sugars. The alcohol content also showed the same pattern as total acids, showing the highest alcohol content of 17.3% (v/v) on day 20. In this study on traditional wine fermentation using an RFID system, we showed that pH, soluble sugar, and alcohol content can be adopted as key indicators for quality control and standardization of traditional wine manufacturing.

Photolithographic Formation of GOD Immobilized Membranes for ISFET Glucose Sensors (ISFET 포도당센서를 위한 GOD 고정화막의 사진식각 형성법)

  • 김창수;최성문;서화일;김의락;손병기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.58-63
    • /
    • 1992
  • Photolithography techniques were applied for immobilization of GOD membrane on the pH-ISFET with photo-sensitive polymers to realize ISEFT glucose sensor. This IC technology-compatible glucose sensor showed good sensing characteristics in the wide range of 10-1000 mg/dl glucose concentrations.

  • PDF

A Water Quality Control Model using Sensor System (센서 시스템을 이용한 수질 제어 모델)

  • Seo, Shin-Bae;Choi, Kyu-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.455-456
    • /
    • 2007
  • Nowaday it is main issues for us to protect from the polluted water which is flowing in streams and rivers simultaneously. This paper proposed a water maintenance control system using pH sensor. Also the work enables water analysis downloading VHDL coding to FPGA through Max+plus II simulation tool for display realization.

  • PDF

THE DEVELOPMENT OF INDWELLING WIRELESS PH TELEMETRY OF INTRAORAL ACIDITY (구강 내 산도의 생체 내 측정을 위한 wireless pH telemetry의 개발)

  • Kim, Hyung-Jun;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • The purpose of this study was to develop the wireless pH telemetry lasting longer than 24 hours in the mouth to overcome the limits of conventional wire telemetry previously used for salivary and plaque pH measurement, and to assess its effectiveness. We developed a wireless pH telemeter which can measure and store the pH profile data during more than 24 hours. It was composed of intraoral part; pH sensor of antimony electrode, battery and microprocessor for data storage, and extraoral part; control/data receiver and data analyzing software which was newly made for this device. After inspecting wireless electrode for accurate measurement, it was attached to the removable intraoral appliance and delivered to the volunteer who was told to wear except brushing time, retrieved after 24 hours and finally the pH profile data was extracted and analyzed. When compared with conventional wire telemetry, this device showed similar results and induced less discomfort to examinees. The data showed pH changes at same time when examinees ate various scheduled foods and beverages. With this method it became possible to accurately measure pH changes within mouth for long time in accordance with individual's lifestyle, definitely reducing the discomfort inflicted to the examinees' life.

  • PDF