• Title/Summary/Keyword: p-side-down

Search Result 67, Processing Time 0.031 seconds

EFFECT OF "STEP-DOWN" AND "BALANCED FORCE" PREPARATION METHODS ON THE SHAPE OF THE ROOT CANAL (Step-down과 Balanced force 근관성형술식에 의한 근관 형태의 변화)

  • Chin, Cheong-Hee;Kim, Jong-Hwa;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.768-779
    • /
    • 1995
  • This study was performed to investigate the effect of root canal shaping techniques on the change of the shape of prepared root canal. 40 mesiobuccal canals of recently extracted mandibular 1st and 2nd molars were divided into 4 groups and shaped by step-down/balanced force technique, step-down/step-back technique, step-back technique and conventional technique respectively. The change of the shape of root canal was traced by superimposing the radiographs obtained before and after shaping of each root canal. The results were as follows. 1. By the experimented techniques except conventional technique, the root canals were more shaped in convex side of apical area and in concave side of most curved and coronal area than in the other sides(P<0.05). By conventional technique, the root canals were more shaped in convex side than in convave side from apex to orifice(P<0.05). 2. By step-down/balanced force technique, the cancave sides at C and D points of proximal view and C point of clinical view were more shaped than the convex side(P<0.05). Through the entire canal, the concave side was more shaped than the convex side in proximal view(P<0.01). But there was no statistical difference between both sides in clinical view. 3. By step-down/step-back technique, the change of root canal shape was not statistically different in concave and convex sides at each point of both views(P>0.05). And through the entire canal in proximal view, there was no statistical difference in shaping percentage between both sides. But through the entire canal in clinical view, the concave side was more shaped than the convex side(P<0.1). 4. By step-back technique, the convex side at B point of clinical more shaped than the other sides(P<0.05). Through the entire canal in proximal and clinical views, there was no statistical difference in shaping percentage between both sides. 5. Comparing the total shaping percentage among techniques, that in conventional technique was the greatest numerically, and followed by the percentages in step-down/step-back, step-down/balanced force and step-back technique. But, in proximal view, shaping percentages were not statistically different among techniques(P>0.05, ANOVA test). In clinical view, shaping percentages in step-back and conventional techniques were statistically different(P<0.01, ANOVA test). * Proximal view: radiograph taken in mesiodistal direction. * Clincal view: radiograph taken in faciolingual direction. A point : 1mm point from radiographic apex B point : center point between A and C points C point : most curved point of root canal D point : center point between C point and canal oriffice.

  • PDF

P-side-down mounting by using AuSn alloy solder of semiconductor laser (반도첼 레이저의 AuSn 합금 솔더를 사용한 p-side-down방식의 마운팅)

  • Choi, S.H.;Heo, D.C.;Bae, H.C.;Han, I.K.;Lee, C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.273-275
    • /
    • 2003
  • 본 실험은 고출력 반도체 레이저의 p-side-down 마운팅용 솔더로서 AuSn 합금 솔더(80wt%:20wt%)의 적합성에 대해 연구하였다. $1{\mu}m$이하의 균일도로 폴리싱 된 Cu heat sink의 표면에 두께 $1{\mu}m$의 Ni로 코팅을 한다음, AuSn 다층박막은 e-beam 증착기로 AuSn 합금 솔더는 열증착기로 각각 증착하였다. 열처리는 산화 방지를 위해 $N_2$ 분위기에서 행하였으며, 동일한 압력으로 마운팅을 하였다. 표면의 거칠기와 형상은 AFM(Atomic Force Microscope)과 SEM(Scanning Electron Microscopy)으로 그리고 Au와 Sn의 성분비는 AES(Auger Electron Spectroscopy) 로 비교하였다. 또한 CW(연속발진)을 통한 L-I(Light-Current)측정을 통해 본딩상태를 비교하였다.

  • PDF

Semiconductor Laser diode Die bonding Using AuSn solder (AuSn 솔더를 사용한 반도체 레이저의 본딩)

  • Choi, S.H.;Bae, H.C.;Heo, D.C.;Han, I.K.;Cho, W.C.;Choi, W.J.;Park, Y.J.;Lee, J.I.;Lee, C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.203-205
    • /
    • 2003
  • 레이저 다이오드를 p-side-down 방식으로 본딩하기 위하여 AuSn 솔더합금을 증착한 후 온도와 압력, 시간을 변화시켜 본딩상태를 조사하였다. CuW위에 adhsion layer와 확산방지층을 각각 $500{\AA}$$2000{\AA}$을 증착하였으며 솔더층으로 AuSn을 $2.6{\mu}m$ 증착 하였다. 열처리는 질소 분위기에서 행하였으며, 표면의 거칠기는 AFM으로 측정하였다.

  • PDF

칩구조와 칩마운트에 따른 InGaN LED의 광추출효율

  • Lee, Ju-Hui;Hong, Dae-Un;Gang, Ui-Jeong;Lee, Seong-Jae
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2005.02a
    • /
    • pp.156-157
    • /
    • 2005
  • Monte Carlo photon simulation 기법을 사용하여 광추출효율 관점에서 InGaN LED를 분석하였다. InGaN/sapphire 칩의 경우, AlInGaP나 InGaN/SiC 칩에서와는 달리, 칩의 측벽면을 기울여 주는데서 오는 광추출효율 개선 효과는 매우 미미하였다. 이는 InGaN/sapphire 칩의 경우 사파이어 기판의 굴절률 상대적으로 작아서 활성층으로부터 생성된 광자들의 상당량이 기판으로 넘어갈 때 전반사현상으로 말미암아 기판으로 넘어가지 못하고 상대적으로 두께가 매우 얇은 에피택시 층에 갇히기 때문으로 파악되었다. 이와 같은 효과는 epitaxial side down mount의 광추출효율이 크게 개선되지 못하는 원인으로도 작용하게 되는데, epitaxial side down mount의 잠재력을 살릴 수 있는 방안의 하나는 texture된 기판위에 결정층을 성장시키는 것이라고 할 수 있다.

  • PDF

Photon Extraction Efficiency in InGaN Light-emitting Diodes Depending on Chip Structures and Chip-mount Schemes (InGaN LED에서 칩 구조 및 칩마운트 구조에 따른 광추출효율에 관한 연구)

  • Lee, Song-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.275-286
    • /
    • 2005
  • The performance of the InGaN LED's in terms of the photon extraction efficiency has been analyzed by the Monte Carlo photon simulation method. Simulation results show that the sidewall slanting scheme, which works well for the AlInGaP or InGaN/SiC LED, plays a very minimal role in InGaN/sapphire LED's. In contrast to InGaN/SiC LED's, the lower refractive index sapphire substrate restricts the generated photons to enter the substrate, minimizing the chances for the photons to be deflected by the slanted sidewalls of the epitaxial semiconductor layers that are usually very thin. The limited photon transmission to the sapphire substrate also degrades the. photon extraction efficiency especially in the epitaxial-side down mount. One approach to exploit the photon extraction potential of the epitaxial-side down mount may be to texture the substrate-epitaxy interface. In this case, randomized photon deflection off the textured interface directly increases the number of the photons entering the sapphire substrate, from which they easily couple out of the chip and thereby improving the photon extraction efficiency drastically.

Effect of Side Walking Training on Balance Confidence, Falls Efficacy and Fall Risk in Acute Stroke Patients: A Randomized Controlled Pilot Study (측방보행 훈련이 급성기 뇌졸중 환자의 균형 자신감, 낙상 효능감, 낙상 위험도에 미치는 영향: 무작위 대조 예비 연구)

  • Joo, Min-Cheol;Jung, Kyeoung-Man
    • Quality Improvement in Health Care
    • /
    • v.27 no.1
    • /
    • pp.43-50
    • /
    • 2021
  • Purpose: The aim of this study was to determine the effect of side walking on balance confidence, falls efficacy and fall risk in acute stroke patients. Methods: The study included 14 patients with acute stroke who were randomly allocated to a side walking group (Experimental group, N=7) and a forward walking group (Control group, N=7). Both groups performed the exercise 5 times a week for 2 weeks. Outcomes were assessed using Korean-Activities-specific Balance Confidence Scale (K-ABC), Korean-Fall Efficacy Scale (K-FES), Korean-Fullerton Advanced Balance Scale (K-FAB). Results: After 2 weeks of training, both groups showed significantly improved ABC, FES, FAB (p<.05 in both groups). However, the ABC, FES, FAB in the experimental group was significantly better than in the control group (p<.05). Conclusion: These findings indicate that side walking training may be effective at improving balance confidence and decreasing fall down risk in early stroke patients. Therefore, side walking training may be recommended as an intervention in reducing the incidence of falls in acute stroke patient.

Double Side SMT and Molding Process Development for mPossum Package

  • Kim, ByongJin;Cho, EunNaRa;Kim, ChoongHoe;Lee, YoungWoo;Lee, JaeUng;Ryu, DongSu;Jung, GyuIck;Kang, DaeByoung;Khim, JinYoung;Yoon, JuHoon;Kim, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2016
  • 3-Dimensional System in Package (3-D SiP) structure (Amkor calls it mPossum-molded Possum) using double side Surface Mount Technology (SMT) and double side molding was evaluated in order to achieve small/thin form factor as well as good functionality by integration and double side layout. As the new platform on laminate substrate basis, molding process was challenge in mold flow balance at top and bottom side and package warpage control over the overall assembly process. There were two types of different molding process evaluated with 1) 1-step molding which was done at both side at the same time and 2) 2-step molding which was done at the conventional molding process twice. Mold simulation helped to narrow down the material selections and parameters available before actual sample build. There were many challenges for this first trial in design/ parameter and material types but optimized them to enable this structure.

p-Coumaric Acid Potently Down-regulates Zebrafish Embryo Pigmentation: Comparison of in vivo Assay and Computational Molecular Modeling with Phenylthiourea

  • Kim, Dong-Chan;Kim, Seonlin;Hwang, Kyu-Seok;Kim, Cheol-Hee
    • Biomedical Science Letters
    • /
    • v.23 no.1
    • /
    • pp.8-16
    • /
    • 2017
  • p-Coumaric acid is an organic compound that is a hydroxyl derivative of cinnamic acid. Due to its multiple biological activities p-coumaric acid has been widely studied in biochemical and cellular systems and is also considered as a useful therapeutic candidate for various neuronal diseases. However, the efficacy of p-coumaric acid on zebrafish developmental regulation has not been fully explored. In this study, therefore, we first investigated the action mechanism of the p-coumaric acid on the zebrafish development in a whole-organism model. p-Coumaric acid treated group significantly inhibited the pigmentation of the developing zebrafish embryos compared with control embryos without any severe side effects. In addition, p-coumaric acid down-regulated more effectively in a lower concentration than the well-known zebrafish's melanogenic inhibitor, phenylthiourea. We also compared the molecular docking property of p-coumaric acid with phenylthiourea on the tyrosinase's kojic acid binding site, which is the key enzyme of zebrafish embryo pigmentation. Interestingly, p-coumaric acid interacted with higher numbers of the amino acid residues and exhibited a tight binding affinity to the enzyme than phenylthiourea. Taken all together, these results strongly suggest that p-coumaric acid inhibits the activity of tyrosinase, consequently down-regulating zebrafish embryo pigmentation, and might play an important role in the reduction of dermal pigmentation. Thus, p-coumaric acid can be an effective and non-toxic ingredient for anti-melanogenesis functional materials.

Plant Phenolics Ferulic Acid and P-Coumaric Acid Inhibit Colorectal Cancer Cell Proliferation through EGFR Down-Regulation

  • Roy, Nabarun;Narayanankutty, Arunaksharan;Nazeem, PA;Valsalan, Ravisankar;Babu, TD;Mathew, Deepu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4019-4023
    • /
    • 2016
  • Background: Colorectal cancer (CRC) or bowel cancer is one of the most important cancer diseases, needing serious attention. The cell surface receptor gene human epidermal growth factor receptor (EGFR) may have an important role in provoking CRC. In this pharmaceutical era, it is always attempted to identify plant-based drugs for cancer, which will have less side effects for human body, unlike the chemically synthesized marketed drugs having serious side effects. So, in this study the authors tried to assess the activity of two important plant compounds, ferulic acid (FA) and p-coumaric acid (pCA), on CRC. Materials and Methods: FA and pCA were tested for their cytotoxic effects on the human CRC cell line HCT 15 and also checked for the level of gene expression of EGFR by real time PCR analysis. Positive results were confirmed by in silico molecular docking studies using Discovery Studio (DS) 4.0. The drug parallel features of the same compounds were also assessed in silico. Results: Cytotoxicity experiments revealed that both the compounds were efficient in killing CRC cells on a controlled concentration basis. In addition, EGFR expression was down-regulated in the presence of the compounds. Docking studies unveiled that both the compounds were able to inhibit EGFR at its active site. Pharmacokinetic analysis of these compounds opened up their drug like behaviour. Conclusions: The findings of this study emphasize the importance of plant compounds for targeting diseases like CRC.

The Relationships Between Valgus Collapse Knee Position and Quadriceps Activity During a Single Limb Step Down in Female Subjects (젊은 여성의 한쪽 다리 스텝다운 동작 시 슬관절 외반 정도와 대퇴사두근 근활성도 간의 상관관계)

  • Lee, Se-Hee;Moon, Young;Song, Ji-Hyun;Kim, Suhn-Yeop;Jang, Hyun-Jeong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.41-47
    • /
    • 2012
  • Background: This study was designed to investigate the correlation between electromyography (EMG) activities in the vastus medialis oblique (VMO) vs vastus lateralis (VL) activity ratio and the valgus collapse knee position while stepping down. Methods: Twenty healthy women volunteered to participate in this study. We measured the frontal-plane projections of the knee valgus angle, knee valgus distance, and hip adduction angle by using a digital camcorder. After 3 repetitions of the step down (dominant side) exercise, the findings of the static and dynamic phases were analyzed. EMG activities data of the VMO:VL activity ratio were recorded during the step down exercise and were normalized to the maximal voluntary isometric contraction (MVIC) of the quadriceps. A paired t-test was used to compare the findings of the static and dynamic phases. We analyzed the Spearman's rank order correlation coefficient between the and VMO:VL ratio. Results: Hip adduction angle, knee valgus angle, VMO activity, VL activity, VMO:VL activity ratio were statistically higher in the dynamic phase than in the static phase (p<.05). Frontal-plane projections of knee valgus angle were significantly correlated with hip adduction angle (r=.459, p<.05) and knee valgus distance (r=.505, p<.05). However, the EMG activity ratio of the VMO and the VL did not show a significant change during step down exercise with respect to hip adduction angle (p=.875), knee valgus angle (p=.618), and knee valgus distance (p=.701). Conclusion: The results from this study indicate that frontal-plane projections of knee valgus angle were associated with hip adduction angle and knee valgus distance. On the basis of these results, the knee valgus distance may be used to determine the valgus collapse knee position while stepping down.

  • PDF