• Title/Summary/Keyword: ozone generator

Search Result 99, Processing Time 0.026 seconds

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

A Study on the High Efficiency PR Strip technology by using the Ozone Process (오존공정을 이용한 고효율 PR 제거기술 연구)

  • Son, Young-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • we have been studied on the realization of the boundary layer controlled ozone process and related facilities in order to apply for the photo-resist strip process in the semiconductor and flat panel display manufacturing. By means of developing the technology for the high concentration ozone production, it was possible to realized the boundary layer control ozone process by vapor. As a result of the silicon wafer PR strip test, we obtained the strip rate of about 400nm/min at the ozone concentration of 16wt% and flow rate of 8[liter/min.].

Reclamation of Effluent Textile Wastewater Using Micro/nano Bubbles-Dissolved Ozone Flotation Process (초미세기포-용존오존부상(DOF)공정을 이용한 염색폐수 처리수의 재이용)

  • Jung, Byung-Gil;Lee, Ki-Hyung;Jung, Jin-Hee;Jang, Seong-Ho;Cho, Do-Hyun;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.291-299
    • /
    • 2011
  • The main objectives of this research are to investigate characteristics of ozone solubility due to low solubility of conventional bubbles-ozone generators, evaluate the treatment characteristics of reclaiming textile wastewater for industrial water by means of micro/nano bubbles-dissolved ozone flotation(MNB-DOF) process. The textile wastewater used in this research was obtained from final effluent of the textile wastewater in B city. There is a 400L reactor which consists of a micro-nano bubble system and a ozone generator for experiments. As a result of generating micro-nano bubbles (below $0.5{\mu}m$) by using of MNB-DOF process, it improved ozone solubility due to higher ozone transfer rates. Consequently, the shorter ozonation time clearly indicates the lower power costs. The reported results clearly indicated that MNB-DOF process can be effectively and inexpensively. Results of the experiments through MNB-DOF process in this study satisfy all reclaiming standards as industrial water: pH 6.5~8.5, SS 10 mg/L or below, $BOD_5$) 6 mg/L or below, turbidity 10 NTU or below, Coliforms 1,000/100 mL or below. Therefore there is a possibility of the reclaiming of the textile wastewater as industrial water.

Discharge and Ozone Generation Characteristics by Permittivity of Dielectric Material installed in Water Surface Discharge (수표면 방전에 투입된 유전체의 유전율에 따른 방전 및 오존발생특성)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.56-63
    • /
    • 2003
  • A silent type ozone generator using water surface has been studied and improved its ozone generation characteristics by installing dielectric heads in the just under the surface of the wale- At this time, different permittivitis of dielectric beads were used to change the discharge condition of water surface. The current-voltage characteristics and characteristics of ozone generation quantity of the test system were investigated and discharge photos of glass beads were observed The height of Taylor cone may be the cause of the discharge bridge to decrease the ozone generation on the discharge spacing. In this study, the hight of Taylor cone could be controlled greatly by installing dielectric beads just under the water surface. Therefore a higher ozone generation also could be obtained. As the permittivity of dielectric material increased. discharge starting voltage was advanced and maximum 110 ppmy of ozone was generated by using the ferroelectric ball.

A Study on the characteristics and Development of Power supply for ozonizer (오존 발생기용 전원 장치 개발 및 특성에 관한 연구)

  • Kim, Jong-Hae;Bae, Sang-June;Lee, Young-Sik;Jo, Gee-Yeun;Jeong, Seung-Kyun;Lee, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2069-2071
    • /
    • 1997
  • The power semiconductor switching devices(PSSD) continuously developed, Power Electronic Technology using PSSD is gradually extended. The high frequency inverter to generate the large power high frequency subject to power electronic technology pursuit various application. Also, in emboss with environmental destruction problem cause the atmosphere and the water pollution to growth of the commercial society, the research in favor of cleansing environmental a pollutant actively proceed. This paper describe study on the ozone generation power supply using the high frequency electric field method and the lamp type ozone generator using photochemistry, one of method of gene-rate ozone.

  • PDF

Ozone Generation Characteristic Utilizing a Water Surface Discharge (수표면 방전을 이용한 오존발생특성)

  • Kim, In-Woong;Kim, Chan-Gyu;Park, Seung-Lok;Moon, Jae-Duck
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1763-1765
    • /
    • 2002
  • A silent discharge type ozone generator using a water surface as an electrode has been proposed and investigated experimentally. A water surface has many Taylor cones when the ac voltage is applied on its surface, which increase the discharge surface greatly. In this paper, it was studied about the effect of the water conductivity. As increasing the water conductivity, the amount of generated ozone was increased and the silent discharge on the water surface took place steadily and calmly.

  • PDF

A case study of carnation productivity improvement using a ozone-negative ion generator (오존-음이온 발생장치를 이용한 카네이션 생산성 향상 사례 연구)

  • Song, Hyun-Jig;Lee, Sang-Keun;Yoon, Dae-Hee;Park, Won-Zoo;Lee, Kwang-Sik;Choi, Sang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.271-273
    • /
    • 2005
  • In order to carnation productivity improvement, ozonizer and negative ionizer has been designed and manufactured. The ozone is generated by DC positive streamer discharge and the negative ion is generated by DC negative discharge. When the ozone and negative ion are supplied growth room and farm to carnation cultivation, the carnation productivity is improved.

  • PDF

Effects of Gaseous Ozone Exposure on Bacterial Counts and Oxidative Properties in Chicken and Duck Breast Meat

  • Muhlisin, Muhlisin;Utama, Dicky Tri;Lee, Jae Ho;Choi, Ji Hye;Lee, Sung Ki
    • Food Science of Animal Resources
    • /
    • v.36 no.3
    • /
    • pp.405-411
    • /
    • 2016
  • The effects of gaseous ozone exposure on the bacterial counts and oxidative properties were evaluated in duck and chicken breast fillets, which were stored under a continuous flux of gaseous ozone (10×10−6 kg O3/m3/h) at 4±1℃ for 4 d. The ozone generator was set to on for 15 min and off for 105 min, and this cyclic timer was set during storage. Ozone effectively reduced the growth of coliform, aerobic and anaerobic bacteria in both chicken and duck breast. However, lipid oxidation occurred faster in duck breast than chicken breast with higher degree of discoloration, TBARS value, and antioxidant enzyme (glutathione peroxidase and catalase) activity decline rates. It is concluded that ozone effectively controlled the growth of bacteria in both chicken and duck breast with less effects on oxidative deterioration in chicken breast.

A Study on the Ozonized Water Production technology for the PR Strip Process (PR 제거공정 적용을 위한 오존 수 생성기술 연구)

  • Son Young Su;Chai Sang Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.13-19
    • /
    • 2004
  • We have been studied on the high concentration ozonized water production technology which substitute for the SPM wet cleaning solution process as the PR strip process after the photolithography process in the semiconductor and flat panel display manufacturing. In this work, we have developed the surface discharge type ozone generator which has the characteristics of the 12 [wt%] ozone concentration at the oxygen gas flow of 0.5[ℓ/min] oxygen per cell and also developed the high efficiency ozone contactor for the mixing ozone gas with deionized water. As the production test results of the ozonized water, we obtained the ozonized water concentration above 80[ppm] at the 10[wt%] ozone gas concentration, and also had a good result of the PR strip rate of 147[nm/min]. at the 70[ppm] ozonized water.

Ozone Processing Storage Characteristic of Main Herb Medicines (주요 한약재의 오존처리저장 특성)

  • Woo, Sung-Hun;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.66-72
    • /
    • 2008
  • Recently, many storing methods were applied to keep quality of herb medicines during storage. Among of thent we tried to research a method to store after dissolving remaining harmful bacillus and agricultural chemicals of herb medicines. We confirmed that ozone processing is superior at the sterilization of bacteria and virus from the leading research about ozone generator, and then we made research method to apply with the sterilization and storing processing of herb medicines using ozone (OPS). In this study we chose herb medicines of 4 kinds which have been sold much in the market, evaluated the characteristics. Namely, we used ozone lamp in a storage system and investigated the sterilization characteristic of herb medicines. We executed a quantitative analysis of the general ingredient and the physiological activity ingredient to investigate whether the original ingredient and the quality of herb medicines is preserved, after doing an ozone md storing processing for a long term.