• Title/Summary/Keyword: ozone exposure

Search Result 158, Processing Time 0.035 seconds

Ozone Exposure Assessment by Population Characteristics: A Case Study for High Ozone Days in Busan (인구특성을 고려한 노출평가: 부산지역 고농도 오존일 사례연구)

  • Hwang, Mi-Kyoung;Bang, Jin-Hee;Oh, Inbo;Kim, Yoo-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.71-81
    • /
    • 2015
  • Objectives: Photochemical ozone pollution is associated with increased mortality risk. This study aims to assess the population exposure to ozone according to population characteristics for high ozone days in the Busan metropolitan region (BMR). Methods: The ozone exposure assessment in this study was performed using the WRF-CMAQ simulated ozone concentrations and the population data in the BMR. The settled and daytime population and their activity were considered to conduct the static and dynamic ozone exposure assessment. Results: Applying a static exposure assessment, in case that high ozone occurred throughout Busan area, the highest exposure levels were evaluated in urban neighborhoods. In case of ozone pollution in outer Busan, because sensitive groups have been relatively higher exposure, this case was also evaluated as part of that should not be overlooked. The dynamic exposure was higher than static exposure because the number of population exposed to ozone of high concentration is increased. This approach is important in a regard consider that daytime population distribution when high ozone occur. Conclusion: This study shows the different population exposure according to various ozone distributions for each episode day. Considering demographic characteristic such as population density and activity should be important to understanding the population exposure assessment when ozone pollution occurs.

Effect of Gaseous Ozone Exposure on the Bacteria Counts and Oxidative Properties of Ground Hanwoo Beef at Refrigeration Temperature

  • Cho, Youngjae;Muhlisin, Muhlisin;Choi, Ji Hye;Hahn, Tae-Wook;Lee, Sung Ki
    • Food Science of Animal Resources
    • /
    • v.34 no.4
    • /
    • pp.525-532
    • /
    • 2014
  • This study was designed to elucidate the effect of ozone exposure on the bacteria counts and oxidative properties of ground Hanwoo beef contaminated with Escherichia coli O157:H7 at refrigeration temperature. Ground beef was inoculated with 7 Log CFU/g of E. coli O157:H7 isolated from domestic pigs and was then subjected to ozone exposure ($10{\times}10^{-6}kg\;O_3h^{-1}$) at $4^{\circ}C$ for 3 d. E. coli O157:H7, total aerobic and anaerobic bacterial growth and oxidative properties including instrumental color changes, TBARS, catalase (CAT) and glutathione peroxidase (GPx) activity were evaluated. Ozone exposure significantly prohibited (p<0.05) the growths of E. coli O157:H7, total aerobic and anaerobic bacteria in ground beef samples during storage. Ozone exposure reduced (p<0.05) the CIE $a^*$ value of samples over storage time. The CIE $L^*$ and CIE $b^*$ values of the samples fluctuated over storage time, and ozone had no clear effect. Ozone exposure increased the TBARS values during 1 to 3 d of storage (p<0.05). The CAT and GPx enzyme activities were not affected by ozone exposure until 2 and 3 d of storage, respectively. This study provides information about the use of ozone exposure as an antimicrobial agent for meat under refrigerated storage. The results of this study provide a foundation for the further application of ozone exposure by integrating an ozone generator inside a refrigerator. Further studies regarding the ozone concentrations and exposure times are needed.

Effects of Atmospheric Ozone on the Rice Blast Pathogen Pyricularia grisea

  • Hur, Jae-Seoun;Kim, Ki-Woo;Kim, Pan-Gi;Yun, Sung-Chul;Park, Eun-Woo
    • The Plant Pathology Journal
    • /
    • v.16 no.1
    • /
    • pp.19-24
    • /
    • 2000
  • The direct effects of acute $\textrm{O}_3$ on the growth, sporulation and infection of Pyricularia grisea, rece blast pathogen, were investigated to understand the interactions between ozone and the pathogen. Acute exposure of 200 nl $\textrm{l}^{-1}$ ozone for 8 h significantly reduced conidia germination on water atar. Ozone exposure of 200 nl $\textrm{l}^{-1}$ for 8h per day for 5 days had no effect on increase in colony diameter, but severely damaged actively growing aerial mycelia. However, the damage to mycalia was recovered during the following 16 h exposure of unpolluted air. Conidial production was also stimulated by the acute ozone exposure for 5 days. The conidia exposed to the acute ozone for 5 days normally germinates but slightly reduce appressoria formation on rice leaf. However, the conidia produced by artificial stimulation under the same ozone concentration for 10 days showed significant reduction in appressorea for mation on a hydrophobic film. This study suggests that the acute ozone could ingibit appressoria formation as well as vegetative growth of the pathogen, resulting in decrease in rece blast development in the field during summer when high ozone episodes could occur occasionally.

  • PDF

Tropospheric Ozone Patterns in the Metropolitan Seoul Area During 1990~1997 Using Two Ozone Indices of Accumulation over the Threshold Concentrations (한계농도 누적 오존지표로 본 1990~1997년의 수도권 오존농도 변화)

  • 윤성철;박은우;장영기
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.429-439
    • /
    • 1999
  • In order to assess the chronic impact of tropospheric ozone on vegetation in the Seoul metropolitan area, it is necessary to quantify ozone exposure. Two ozone indices commonly used to relate ozone exposure to injury of vegetation were calculated. SUM06(SUM of hourly concentrations at or above 0.06 ppm) and AOT40(Accumulated exposure Over a Threshold of 40 ppb) which are widely used as ozone indices in the US and Europe were calculated based on hourly ozone concentrations in 5 areas of Seoul and 5 cities of Kyunggido during 1990~1997. Most SUM06 levels were 1~5ppm.hr, however several areas in Northern and Eastern Seoul reached about 5~7 ppm.hr in 1996~1997. AOT40 values were as high as 17~24 ppm.hr. Although measured SUM06 levels would not be expected to significantly impact vegetation, the overall ozone index, as well as annual average, 95th, and 99th percentile have increased continuously over the last 8 years. Often, ozone concentrations are lower in cities where there is a significant NOx concentration, than in outlying rural agricultural areas where NOx scrubbing is not as important. Concentrations greater than 40 ppb, which can cause chronic ozone toxicity to vegetation, were found mostly in the summer and constitutued about 5~15% of total hourly ozone cocentrations.

  • PDF

Variation of Indoor Average Ozone Concentration within the Radiation Therapy Room by High Energy Radiation (고 에너지 방사선에 기인된 방사선치료실 내 평균 오존 농도의 변화)

  • Lee, Jin-kook;Lee, Hyo-Yeong;Im, In-Chul;Yu, Yun-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.171-180
    • /
    • 2016
  • This study was to evaluate the change in characteristics of concentration of ozone after exposure to high energy radiation in linac room. Background ozone concentration of linac room was measured and compared to ozone concentration around linac room. Background ozone concentration of linac room was mean $17.4{\pm}7.9ppb$. It was 50% of the ozone concentration($36.8{\pm}22.3ppb$) around linac room(p<0.05). The concentration of ozone after exposure to high energy radiation in linac room was elevated to double of background ozone level, intensity after exposure. with exposure time concentration of ozone increased proportionally. It showed maximum level at 130~180seconds and slowed a tendency to saturate. It required more than 10 minutes for ozone concentration in linac room to drop to ozone concentration around linac room. The concentration of ozone after exposure to high energy radiation is high enough to cause specific physical symptoms, such as acute dyspnea or chest pain due to dry cough. Exposure to high concentration of ozone in sealed linac room can aggravate pulmonary disease, so special attention is needed.

Growth, Physiological Responses and Ozone Uptake of Five Betula Species Exposed to Ozone

  • Lee, Jae-Cheon;Han, Sim-Hee;Kim, Pan-Gi;Jang, Suk-Seong;Woo, Su-Young
    • The Korean Journal of Ecology
    • /
    • v.26 no.4
    • /
    • pp.165-172
    • /
    • 2003
  • The objectives of this study were to examine the physiological responses to ozone and to measure ozone uptake rates of Betula species exposed to relatively high concentration of pollutants. At the end of the growing season, photosynthesis, pigments contents, antioxidants (SOD and GR) and ozone uptake rates were measured or estimated at the leaves of five Betula species (Betula costata, B. davurica, B. platyphylla var. japonica, B. schmidtii and B. ermanii) exposed to 100ppb ozone concentration. On the termination of the experiment, growth effects were determined by measuring leaf area and dry weights of leaf, stem and root. Ozone treatment showed the significant reduction the leaf area and dry weight of four Betula species, except for B. ermanii. Shoot / root (SR) ratio of five species represented two different types. SR ratio of B. costata and B. davurica were lower than control, in contrast, SR ratio of B. platyphylla var. japonica, B. schimidtii and B. emani, were higher than that of control. The photosynthetic responses of five species were different in responses to ozone exposure. Four species, except for B. emanii, maintained or increased the stomatal conductance, but B. emanii decreased both stomatal conductance and photosynthesis. SOD activities of five species decreased by the ozone exposure, especially B. ermanii showed the largest reduction, GR activities of B. platyphylla var. japonica and B. schmidtii increased, B. costata and B. emanii decreased. Instantaneous ozone uptake rate was the highest at the leaves of B. ermanii and B. costata, ozone uptake per seedling was the highest at the leaf of B. schmidtii and B. emanii. It was concluded that B. costata, B. davurica and B. platyphylla var. japonica, appeared the growth reduction and visible ozone injury, were sensitive species to ozone, and B. schmidtii with the increased antioxidant activity and B. ermanii without the growth reduction were relatively resistant species to high ozone concentration at the early growing stage.

Effect of Plant Growth Regulators on Minimizing Ozone Injury in Tobacco(Nicotiana tabacum L.) (식물생장조절제(植物生長調節劑) 처리(處理)가 담배의 오존 피해경감(被害輕減)에 미치는 영향(影響))

  • Park, K.S.;Cho, J.H.;Sohn, J.K.;Lee, S.C.
    • Korean Journal of Weed Science
    • /
    • v.18 no.1
    • /
    • pp.54-62
    • /
    • 1998
  • This experiment was conducted to find out the effects of ABA and IAA on activities of antioxidant enzymes, antioxidant content, and growth of tobacco under exposure to ozone. The exposure to ozone in tobacco plant significantly decreased plant height, but it did not show any difference in vegetative characteristics except plant height of IAA $10^{-3}$M treated. Total chlorophyll content of NC 82 was dramatically decreased with increase in days after ozone treatment. However, reduction of chlorophyll was minimized when plant growth regulators were treated before ozone exposure. Three days treament of ozone in tobacco increased ascorbic acid of oxidised form, while slightly decreased `in reduced ascorbic acid by IAA treatment. But seven days of ozone treatment showed increase in ascorbic acid and decrease in dehydroascorbic acid. Ozone treatment did not show any difference in glutathione content and glutathione reductase activity when plant growth regulators were treated. Activities of superoxide dismutase(SOD), ascorbate peroxidase(AP) and guaiacol peroxidase(GP) were increased by the exposure to ozone for three days. However, there were no difference in activities of SOD, AP and GP due to exposure to ozone for seven days. These reactions may be interpreted as protective responses to prevent or alleviate the damage of tobacco plant by ozone exposure.

  • PDF

A Study on the Influence on Medical Care for the Elderly by Exposure to Fine Particulate Matter and Ozone (미세먼지와 오존노출에 의한 노인의 의료 이용 영향에 대한 연구)

  • Jung, En-Joo;Na, Wonwoong;Lee, Kyung-Eun;Jang, Jae-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.30-41
    • /
    • 2019
  • Objectives: The effects of particulate matter and ozone on health are being reported in a number of studies. These effects are likely to be stronger on the elderly population, but studies in this regard are scarce. The purpose of this study was to examine the effects of particulate matter ${\leq}2.5{\mu}m$ and ozone on the acute health status of the elderly population. Methods: In order to analyze the health status of the elderly population, the NHIS-Senior Cohort data was used. In this study of people 60 years or older in Seoul, the number of outpatient visits and ER visits between 2002 and 2013 were calculated. Each disorder and the lag effect were analyzed separately. Particulate matter and ozone were analyzed using both the single exposure model and the adjusted multi-exposure model. Results: In the single exposure analysis with PM2.5 as the exposure variable, with each increase of $10{\mu}g/m^3$, the number of outpatient visits increased by 1.0081 times, vascular disease 1.0065 times, chronic pulmonary disease 1.0086 times, and diabetes 1.0055 times. In the multi-exposure model adjusting for ozone, the number of outpatient visits increased by 1.0066 times. There was a one-day lag effect and 1.0066 times increase between PM2.5 and ER visits in the multi-exposure model and 1.0057 times when adjusted for ozone (p value <0.10). There was a one-day lag effect in all multi-exposure models with ozone as the main variable, and when the particulate matter was adjusted, there was a one-day delay and 1.0143 times increase in ER visits. Conclusions: In our study, an increase in the number of outpatient and ER visits in the elderly population in accordance with the increase in PM2.5 and ozone was found. The association found in our study could also produce a socioeconomic burden. Future studies need to be performed in regards to younger populations and other air pollutants.

A Study of Ozone Variations in a Semiconductor Fabrication Facility and Office Related to the Ozone Concentration in the Outdoor Air (외기 오존 농도에 따른 반도체 작업환경 및 사무실에서의 오존 농도 변화 연구)

  • Lee, Ji-Eun;Jung, Myung-Koo;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.188-197
    • /
    • 2016
  • Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.

Comparison of Household Trihalomethanes (THMs) Exposure Associated with Use of Municipal Tap Water Treated with Chlorine or Ozone-Chlorine (염소살균과 오존-염소살균 수도수의 사용과 관련한 가정 트리할로메탄 노출 비교평가)

  • Jo, Wan Geun;Gwon, Gi Dong;Dong, Jong In;Jeong, Yong
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.627-635
    • /
    • 2004
  • Evaluated were household THMs exposure associated with the use of municipal tap water treated with chlorine and with ozone-chlorine. The current study measured the THMs concentrations in the tap water and indoor and outdoor air in the two types of household, along with an estimation of THMs exposure from water ingestion, showering, and the inhalation of indoor air. Chloroform was the most abundant THMs in all three media, yet no bromoform was detected in any sample. Contrary to previous findings, the fall water THMs concentrations exhibited no significant difference between the chlorine and ozone-chlorine treated water. However, the spring median chloroform concentration in the tap water treated with chlorine (17.6 ppb) was 1.3 times higher than that in the tap water treated with ozone-chlorine (13.4 ppb). It is suggested that the effects of the water parameters should be considered when evaluating the advantage of ozone-chlorine disinfection for THMs formation over chlorine disinfection. The indoor air THMs concentration trend was also consistent with the water concentration trend, yet the outdoor air THMs concentrations did not differ significantly between the two types of household. The indoor to outdoor air concentration ratios were comparable with previous studies. The THMs exposure estimates from water ingestion, showering, and the inhalation of indoor air suggested that, for the residents living in the surveyed households, their exposure to THMs in the home was mostly associated with their household water use, rather than the indoor air. The THMs exposure estimates from tap water ingestion were similar to those from showering.