Abstract
Objectives: The purpose of this study was to evaluate the ozone exposure levels and the variations in ozone concentration in a semiconductor fabrication facility and office in relation to the ozone concentration in the outdoor air. Methods: This study was performed in an office, semiconductor fabrication facility(such as etching, diffusion, diffusion plenum), and outdoors from June to August, 2015. Measurements were taken six times at the same places using an active sampler(pumped) and real-time equipment. Ozone monitoring by the active sampler method and analysis were carried out by OSHA Method ID-214. Real-time measurement was carried out by ozone measuring equipment using a non-dispersive ultraviolet absorption method. Results: Ozone concentrations in the semiconductor fabrication facility and office were 0.7~7.1 ppb in area samples and 0.72~4.07 ppb in real-time measurement, which were 0.88~8.88% of the occupational exposure limit. The concentration of ozone generated by a laser printer in the office was less than 2 ppb. There was not a significant difference between ozone concentrations before and after using the laser printer. The indoor/outdoor concentration ratio(I/O ratio) in the semiconductor fabrication facility and office was 0.05 and 0.06, respectively. Conclusions: All the samples contained ozone levels lower than the occupational exposure limit and it was confirmed that the concentration of outdoor ozone had no significant effect on indoor ozone concentration.
Keywords
area sampling; office; ozone; real time monitoring; semiconductor;
Citations & Related Records
Times Cited By KSCI : 10  (Citation Analysis)
연도 인용수 순위
1 ACGIH Threshold Limit Values for Chemical Substances and Physical Agents & Biological Exposure Indices with 7th Edition Documentation., 2015
2 An HJ, Han JH, Lee MH, Kang EH. The Long-term variations of Ozone and Nitrogen Oxides in Suwon city during 1991-2012. Journal of Korean Society for Atmospheric Environment, 2015; 31(4):378-384   DOI
3 Chae YM, kim Hj, Roh SC. Pulmonary Function Changes of Ozone Exposed Workers in a Film Manufacturion Company. Korean J Occup Environ Med, 2007;19(3):251-222
4 Cho EJ, Kwak J, Kim Mk. A Study on Distribution characteristics and Improvement of Indoor Air Quality in Socially Disadvantaged Class. The Annual Report of Busan Metropolitan city Institute of Health & environment, 2011;20(1):122-137
5 Choi JW, Park JH, Kim IY, Kwak YP. A Study on the Regulation and Means of Compliance for Ozone Concentration in the Cabin. Journal of Korean Society for Aviation and Aeronautics, 2003; 11(2): 79-92
6 Choi KM, Lee JE, Cho KY, Kim KS, Cho SH. Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process. J Korean Soc Occup Environ Hyg, 2015; 25(2):202-210   DOI
7 Chung OY, Jeong SG, Kim JH, Kim SM. Consideration of Ozone Removal and Control in Built Environment by Building Materials. Korean Journal of Air Conditioning and Refrigeration Engineering. 2012; 24(6): 467-475   DOI
8 Chung YS, Chung JS. On Surface Ozone Observed in the Seoul Metropolitan Area during 1989 and 1990. J.KAPRA, 1991; 7(3): 169-179
9 Dix HM. Environmental pollution. John Wiley & Sons Inc., New York, 1981; Chapter 6:65
10 Eom SH, Lee CG, Lee WK. An Analysis of Relation Between Climate and Air Pollution in Incheon. Journal of Information Technology and Architecture, 2015; 12(2):271-276
11 Haagen-Smit A.J, Bradley C.E., Fox M.M. Ozone Formation in Photochemical Oxidation of Organic Substances. Ind Eng Chem, 1953; 45(9): 2086-2089   DOI
12 Hong SC, Jou HM, Cho RJ, Lee CW, Jung YT, Son BS. A Study of Indoor Air Quality of Public Facilities in Chung-Nam Area. J.of ESE, 2008; 23(2): 35-45
13 Kagi N, Fujii S, Horiba Y, Namiki N, Ohtani Y et al. Indoor Air Quality for Chemical and Ultrafine Particle Contaminants from Printers. Building and Environment, 2007; 42(5): 1949-1954   DOI
14 Ilgen E., Karfich N., Levsen K., Angerer J., Schneider P. et al. Aromatic Hydrocarbons in the Atmospheric Environment: part I. Indoor Versus Outdoor Sources, the Influence of Traffic. Atmospheric environment, 2001; 35(7): 1235-1252   DOI
15 Jo SY, Choi SH, Im JY. A Study of Concentrations of Ozone in Gwangyang Area. Journal of Korean Society for Indoor Environment, 2011; 8(3):199-210
16 Jo Wk, Yoon IH, Nam CW. Analysis of Air Pollution in Two Major Korea Cities: trends, seasonal variations, daily 1-hour maximum versus other hour-based concentrations, and standard exceedances, Environmental Pollution, 2000; 11-18
17 Kim JH, Lim JW. Cluster Analysis with Air pollutants and Meteorological Factors in Seoul. Jourmal of Korean Data & Information Science Society, 2003; 14(4):773-787
18 Kim MY, Choi YJ, Kim KH. The Exceedance Patterns of O3 Air Quality Standards from 31 Monotoring Stations in Seoul. Jour. Korean Earth Science Society, 2002;23(8):683-696
19 Korea Environment Institute(KEI). 1998. RE-18. Available from: URL:http://webbook.me.go.kr/DLi-File/F000/150/15108_9028.pdf
20 Korea Occupational Safety and Health Agency(KOSHA). 2005. Available from: URL: https://www.google.co.kr/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&ved=0ahUKEwie_u-034rLAhUHoJQKHRbJDqIQFggfMAA&url=https%3A%2F%2Fwww.kosha.or.kr%2Fcms%2Fgenerate%2FFileDownload.jsp%3Fcontent_id%3D192391%26category_id%3D%26version%3D1.0%26file_name%3D408203_1.1_attachFile3_1.pdf&usg=AFQjCNHo_MLEn-h_hDvXHKMa2fdFx8OvQA&bvm=bv.114733917,d.dGo&cad=rja
21 Ministry of employment and Labor(MoEL). 2005. Available from: URL: http://www.google.co.kr/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&ved=0ahUKEwilsuf6wYzLAhWBE5QKHTUrBgwQFggcMAA&url=http%3A%2F%2Fwww.moel.go.kr%2Fdownload2.jsp%3Ftype%3D%2Fdownload2%2F_20060327130340702.pdf%26file%3D59_%25BF%25C0%25C1%25B8_%25BA%25B8%25B0%25ED%25BC%25AD.pdf&usg=AFQjCNHgHL-bnCLaUh7Xaq_9Sev2y5w3eA
22 Kwon YJ, Woo KH, Kim JS, Yoon SY, Song IU et al. Senven cases of Respiratory symptoms Caused by Acute Ozone Exposure from and Electronics Company. Korean J Occup Environ Med. 2012;24(4):449-459
23 Lai D, Karava P, Chen Q. Study of Outdoor Ozone Penetration into Buildings through Ventilation and Infiltration. Building and Environment, 2015; 93;112-118   DOI
24 Lee S.C, Lam S, Fai HK. Characterization of VOCs, ozone, and PM10 emissions from office equipment in an environmental chamber. Building and Environment. 2001;26(7):837-842
25 Ministry of employment and Labor(MoEL). Exposure Limits for Chemical Substances and Physical Agents(MoEL Public Notice NO. 2013-38); 2013
26 Ministry of employment and Labor(MoEL). Guideline For Office Air Quality (MoEL Public Notice NO. 2015-43):2015
27 Ministry of Environment (MOE). Annual Report of Ambient Air Quality in korea, 2014. 2015
28 Ministry of Environment (MOE). http://webbook.me.go.kr/DLi-File/F000/056/5617_40848.pdf, 2002
29 Mudway IS, Kelly FJ. Ozone and the lung: a sensitive issue. Molecular Aspects of Medicine, 2000; 21(1-2):1-48   DOI
30 National Institute of Environmental Research (NIER). Effects of ozone on the human body. 1995; 35
31 Park MJ. A Study on the Evaluation of Indoor Air Environment in Super High-Rise Dwelling House. Journal of the KIIS, 2002;17(4):119-125
32 Occupational Safety and Health Administration(OSHA). Sampling & Analytical Method, ID-214. 2003
33 Oh IB, Kim YK. Surface Ozone in The Major Cities of Korea : Trends, Diurnal and Seasonal Variations, and Horizontal Distributions. J. KOSAE, 2002; 18(4):253-264
34 Park JH. Temporal Trends and Spatial Comparisons of Ozone Concentrations in Jinju. Journal of Environmental Sciences, 2010; 19(6):761-769   DOI
35 Seo SC, Cho YM, Kim MN, Lee SG, Kim Hj et al. Characterization of Airborne Pollutants Emitted from a Laser printer. J. Korean Soc, Indoor Environ, 2011;8(4):251-262
36 Shin ES, Hwang KC. A Study on the Indoor Air Pollution Quality of Specific Types of Industry to Use Office Equipments. Bulletin of Dongnam Health College, 2003; 21(2): 477-486
37 Sin DC, Park SE, Kim HJ, Kim HH. The measurement of O3 by passive sampler in indoor air of the residences. J. Korean Soc.Atmos.Envion, 2000; 2(11):441-442
38 Singh BP, Kunar A, Singh D, Punia M, Kumar K, Jain VK. An Assessment of Ozone Levels, UV Radiation and their Occupational Health Hazard Estimation during Photocopying operation. Journal of hazardous materials. 2014; 275:55-62   DOI
39 Tian X, Yi Z, Jin T, Wang X. Indoor Ozone pollution and the Purification Technologies. ICIEA, 2015; 487- 490
40 Valuntaite V, Girgzdiene R. Incestigation of ozone emission and dispersion from photocopying machines. Jourmal of environmental engineering and landscape management, 2007; 15(2): 61-67
41 Yap D and Chung YS. Relationship of ozone to meteorological conditions in southern ontario. Preprints 70th Annual meeting air pollution control assoc, Toronto, 1977; 4(16): 77-20