• Title/Summary/Keyword: oxygen flow rate

Search Result 689, Processing Time 0.025 seconds

RETF 액체산소 공급설비 및 엔진 수류시험

  • Han, Yeoung-Min;Cho, Nam-Kyung;Kim, Seung-Han;Chung, Yong-Ghap;Park, Sung-Jin;Lee, Kwang-Jin;Kim, Young-Han;Moon, Il-Yoon
    • Aerospace Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • In this paper, characteristics of cryogenic liquid oxygen was examined during cold flow of KSR-III main engine at each stage. The effect of venting was examined at the stage of cooling and at the pressurization stage, the interaction between nitrogen gas and liquid oxygen was also examined. The characteristic of liquid oxygen in the engine manifold was analyzed. The results showed that venting was the primary role at the cooling process and the interaction of nitrogen gas and liquid oxygen in the run tank is limited at the surface area. With the sampling rate of 1KHz static and dynamic pressure were measured in the rocket engine manifold and in the LOX supply equipment. 32.5mm and 38mm orifice were installed for the tests and pressure condition of liquid oxygen was 23Bar, 29Bar, 41Bar. Increase of orifice diameter and decrease of supply pressure reduced the perturbation of pressure in engine manifold.

  • PDF

Cerebral blood flow enhancement device using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치)

  • Lim, Jung-hyun;Joh, In-Hee;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1083-1089
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm is measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm is calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

Temperature Dependence of Bonding Structure of GZO Thin Film Analyzed by X-ray Diffractometer (XRD의 결정구조로 살펴본 GZO 박막의 온도의존성)

  • Oh, Teresa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.52-55
    • /
    • 2016
  • GZO film was prepared on p-type Si wafer and then annealed at various temperatures in an air conditions to research the bonding structures in accordance with the annealing processes. GZO film annealed in an atmosphere showed the various bonding structure depending on annealing temperatures and oxygen gas flow rate during the deposition. The difference of bonding structures of GZO films made by oxygen gas flows between 18 sccm and 22 sccm was so great. The bonding structures of GZO films made by oxygen gas flow of 18 sccm were showed the crystal structure, but that of 22 sccm were showed the amorphous structure in spite of after annealing processes. The bonding structure of GZO as oxide-semiconductor was observed the trend of becoming amorphous structures at the temperature of $200^{\circ}C$. Therefore, the characteristics of oxide semiconductor are needed to research the variation near the annealing at $200^{\circ}C$.

Decarbonization Kinetics of Molten Iron by Ar+O2 Gas Bubbling (Ar+O2 혼합가스 취입에 의한 용철의 탈탄 반응속도)

  • Sohn, Ho-Sang;Jung, Kwang-Hyun
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.107-113
    • /
    • 2009
  • Molten iron with 2 mass % carbon content was decarbonized at 1823 K~1923 K by bubbling $Ar+O_2$ gas through a submerged nozzle. The reaction rate was significantly influenced by the oxygen partial pressure and the gas flow rate. Little evolution of CO gas was observed in the initial 5 seconds of the oxidation; however, this was followed by a period of high evolution rate of CO gas. The partial pressure of CO gas decreased with further progress of the decarbonization. The overall reaction is decomposed to two elementary reactions: the decarbonization and the dissolution rate of oxygen. The assumptions were made that these reactions are at equilibrium and that the reaction rates are controlled by mass transfer rates within and around the gas bubble. The time variations of carbon and oxygen contents in the melt and the CO partial pressure in the off-gas under various bubbling conditions were well explained by the mathematical model. Based on the present model, it was explained that the decarbonization rate of molten iron was controlled by gas-phase mass transfer at the first stage of reaction, but the rate controlling step was transferred to liquid-phase mass transfer from one third of reaction time.

Optimum Design of Surface Aerator Using Response Surface Method (반응표면 기법을 이용한 생물반응조 표면포기기 최적설계)

  • Yoon, Jong-Hwan
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 2010
  • In this study, we optimized the shape of the surface aerator that will be installed in a biological reactor using the response surface method. Response surfaces of mass flow rate, impeller torque, mass flow rate per impeller torque are generated and used to track the optimum shape of the aerator. MOGA(Multi-Objective Genetic Algorithm)method is adopted to find the optimum results. By increasing the mass flow rate per impeller torque, increase of oxygen supply efficiency to a reactor is anticipated. To verify the usability of the surface aerator, PIV measurements on flow fields inside a scale-downed biological reactor model are carried out.

A Study on the Properties of Indium-Tin-Oxide(ITO) Films Deposited by DC magnetron sputtering method (DC magnetron sputtering 방법으로 형성한 Indium-Tin-Oxide(ITO) 박막의 특성 연구)

  • An, Myung-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.3
    • /
    • pp.473-478
    • /
    • 2006
  • High quality indium tin oxide (ITO) thin films have been prepared by DC magnetron sputtering technique. By controlling the deposition parameters such as substrate temperature and oxygen flow rate, we were able to minimize the negative ion damage during the deposition. Films pr데ared under such conditions were found to posses an excel]ent electrical resistivity of $1.6\times10^{-4}{\Omega}cm$ and also found to have a optical transmission above 90%. We also observe that, increasing the oxygen now rate above 4 sccm leads to an increase in electrical resistivity of the films while the transmission was found to saturate with the increase in the oxygen gas flow.

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

Electrical and structural characteristics of AZO thin films deposited by reactive sputtering (Reactive sputtering 법으로 증착된 AZO 박막의 전기적 및 구조적 특성)

  • Heo, Ju-Hee;Lee, Yu-Lim;Lee, Kyu-Mann
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.1
    • /
    • pp.33-38
    • /
    • 2009
  • We have investigated the effect of the ambient gases on the characteristics of AZO thin films for the OLED (organic light emitting diodes) devices. These AZO thin films are deposited by rf-magnetron sputtering under different ambient gases (Ar, Ar+$O_2$, and Ar+$H_2$) at 300. In order to investigate the influences of the oxygen and hydrogen, the flow rate of oxygen and hydrogen in argon mixing gas has been changed from 0.2sccm to 1sccm and from 0.5sccm to 5sccm, respectively. The AZO thin films were preferred oriented to (002) direction regardless of ambient gases. The electrical resistivity of AZO film increased with increasing flow rate of $O_2$ under Ar+$O_2$ while under Ar+$H_2$ atmosphere the electrical resistivity showed minimum value near 1sccm of $H_2$. All the films showed the average transmittance over 80% in the visible range. The OLED device was fabricated with different AZO substrates made by configuration of AZO/$\acute{a}$-NPD/DPVB/$Alq_3$/LiF/Al to elucidate the performance of AZO substrate.

  • PDF