• Title/Summary/Keyword: outside insulation

Search Result 133, Processing Time 0.047 seconds

A Study of Thermal insulation method using extruded and expanded Poly-ethylene panel contacted to the bathroom inner wall facing on the outside (외기와 면하는 욕실 내측벽에 압출 발포폴리스티렌 패널을 사용한 단열시공기술에 관한 연구)

  • Lee Jong-Jin;Oh Chang-Won;Yeo Sung-Yi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.11-16
    • /
    • 2005
  • This study is for the insulation construction of inner wall in a bathroom facing on the outside in the housings. This new dry construction method can be constructed by a dry panel which is bonded tiles on the extruded and expanded poly-ethylene panel in stead of the existing wet construction method. Compared to the existing method, this panel is light movably and is constructed simply. These representative construction merits are getting wide span in a bath due to reducing wall thickness and saving construction period.

  • PDF

A Experimental Study of Insulation Performance of Insulated Forms Utilizing NT frame Insulation at Low Temperature (저온환경하 NT(Nano Technology)구조 단열재를 사용한 단열거푸집의 열적성능평가에 관한 실험적 연구)

  • Park, Jang-Hyun;Kim, Mok-Kyu;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.179-180
    • /
    • 2015
  • In this study, the experimental study on Insulation performance of insulated forms utilizing NT frame heat insulation at low Temperature. For this study, placing insulated TEGO film plywood based form between two constant temperature and humidity chamber that maintaining 10℃, decrease temperature of one chamber to -10℃ and -20℃. Each of steps, maintaining period of temperature was 1 hour. After placing the insulated form, measure temperature of outside if insulated form. As a result of experiment, temperature difference of Fumed Silica Vacuum insulation was lowest.

  • PDF

Improvement of sound insulation performance of windows according to the specifications of the external electric blinds (외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과)

  • Min-Woo, Kang;Hee-Dong, Lee;Yang-Ki, Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.621-628
    • /
    • 2022
  • The most realistic way to reduce noise outside the building, such as road traffic noise and aircraft noise, is to strengthen the sound insulation performance at the sound collecting points such as balconies, windows, and exterior walls of each building. However, in light of the reality that shading devices outside buildings are not yet widely used, there are not many studies on sound insulation performance improvement using external windows and window devices such as louvers and blinds. In particular, external blinds can not only block the inflow of strong sunlight in the morning and evening from the outside of the building, but also target the sound insulation effect that blocks the peak noise that occurs during commuting hours. In this study, a study was conducted to improve sound insulation performance against external noise by using an external electric blind (EEB), which is one of the most efficient window and door external shading devices. Various sound insulation performance tests were conducted while changing the configuration of external electric blinds developed for light blocking purposes. Through this, it was verified that an additional sound insulation performance of 6 dB can be obtained by installing an external electric blind compared to the reduction performance of general windows.

A Study on the Thermal Characteristics of the Vacuum Jacket Valve for Transporting Liquefied Hydrogen According to the Degree of Vacuum (액화수소 수송용 진공자켓 밸브의 진공도에 따른 열적특성에 대한 연구)

  • OH, SEUNG JUN;JEON, KYUNG SOOK;YOON, JEONG HWAN;CHOI, JEONGJU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.585-591
    • /
    • 2021
  • Liquefied hydrogen have advantage which reduces the volume by about 800 times or more compared to hydrogen gas, so it is possible to increase the storage density. However, liquefied hydrogen produced by cryogenic cooling of 20 K or less at normal pressure has a problem of maximizing the insulation effect that blocks heat introduced from the outside. Representative insulation technologies include vacuum insulation and multi-layer insulation materials and in general, heat blocking is attempted by combining insulation technologies. Therefore, in this study, the pressure of the internal vacuum layer was changed to 10-1, 10-2, 10-3 and 10-4 Torr to confirm the thermal insulation performance of the vacuum jacket valve for transporting liquefied hydrogen. As a result, it was confirmed that the insulation performance improved as the degree of vacuum increased.

A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials (복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

Field Application of the Mass Concrete Using Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열보온양생공법의 한중매스콘크리트 현장적용)

  • Lee, Dong-Gyu;Kim, Jong;Kim, Ki-Hoon;Hwang, Yin-Seong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.1-4
    • /
    • 2007
  • This study investigated the applicability of insulation curing method with double layer bubble sheets to the man concrete subjected to cold weather. Temperature history of the mass concrete indicated that the highest temperature of center section was exhibited at $34^{\circ}C$ while the that of surface section was $25^{\circ}C$. Difference between center and surface was shown to be less $10^{\circ}C$ when the temperature of center section was peak section, and thereby associated temperature cracking index was calculated 1.5, and occurrence probability of temperature cracking was 5%, so there was no temperature cracking caused by internal restraint. No temperature crack was observed by naked eye. It was clear that early frost demage and temperature cracking could be restrained due to reducing temperature difference between inner part and outside in the case double bubble sheets applied to insulation curing method in cold weather. The maturity of mass concrete is higher than outside about $72\sim89^{\circ}$ DD, so it was demonstrated to prevent early frost demage and ensure strength excellently. Insulation curing method with double bubble sheets was more economic than heating curing method.

  • PDF

Automatic Insulation System in Greenhouses (온실의 자동단열시스템에 관한 연구)

  • 이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.29 no.4
    • /
    • pp.117-123
    • /
    • 1987
  • This study was conducted to develop an automatic insulation system to reduce the heat loss through the wall of greenhouses during the nighttime in winter. A double covered model vinyl house was constructed, and blowers were used to fill or remove styrene pellets automatically the inside of the double-wall of the double covered vinyl house. The effects of insulation of the double covered vinyl house insulated with the styrene pellets were analyzed by comparing with the single covered vinyl house. The results obtained from this study can be summarized as follows : 1. The optimum thickness of the double-wall of the double covered vinyl house was found to be 5 to 10 cm. 2.When the outside temperature varied in the range of -8.3 to -1.5$^{\circ}C$ during the nighttime, the inside temperature of the double covered vinyl house insulated with the styrene pellets showed 7.7 to 11.7$^{\circ}C$ and the inside temperature of the single covered vinyl house showed -5.8 to 2.3$^{\circ}C$. Therefore, the effects of insulation of the double covered vinyl house insulated with the styrene pellets were confirmed to be excellent. 3. Also, the excessive increase of the inside temperature in the vinyl house was prevented by the shading effect of the double covered vinyl house insulated with the styrene pellets during the daytime. 4. When the outside temperature varied in the range of 17.7 to 30.0$^{\circ}C$ during the daytime, it was possible to keep the inside temperature at 30${\pm}$4$^{\circ}C$ in the double covered vinyl house by operating the insulation system. 5. The transmissivity of the double covered vinyl house with the styrene pellets removed was 52.4 % on the average.

  • PDF

Heat Loss the Case Study of Office Building (사무소 건축물의 열손실 사례연구)

  • Kim, Kyeong-A;Kim, Bongl-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.51-54
    • /
    • 2011
  • In this study, It has the purpose to evaluate the insulation of the curtain wall of a building on the construction from 1990 to 2011 by measuring the inside and outside surface temperature of the curtain wall. The outside frame surface(mullion bar or spandrel bar) temperature of the curtain wall is 6℃~10℃ higher than that of the surface of glasses or insulation panel of curtain wall in winter. Furthermore the outside surface of frame anchor unit is 2℃~3℃ higher than section of other frame, so it was verified lossing lots of heating.

  • PDF

Analysis on Insulation of Wind Environment and Greenhouse Cover Materials Insulation for Advanced Greenhouse Energy Design in Saemangeum Reclaimed Land (새만금 간척지 첨단온실 에너지 설계를 위한 풍환경 및 온실 피복재의 영향 분석)

  • Hyo-Jae Seo;Il-Hwan Seo;Deuk-ha Noh;Haksung Lee
    • Journal of Bio-Environment Control
    • /
    • v.32 no.1
    • /
    • pp.57-63
    • /
    • 2023
  • The external weather conditions including temperature and wind speed in the Saemangeum reclaimed land is different from that of the inland, affecting the internal environment of the greenhouse. Therefore, it is important to select an appropriate covering material considering the insulation effect according to the type and characteristics of the covering material considering the weather condition in the Saemangeum reclaimed land. A hexahedral insulation chamber was designed to evaluate the insulation efficiency of each glass-clad material in the outside weather condition in reclaimed land. In order to evaluate the insulation effect of each covering material, a radiator was installed and real-time power consumption was monitored. 16-mm PC (polycarbonate), 16-mm PMMA (polymethyl methacrylate), 4-mm greenhouse glass, and 16-mm double-layered glass were used as the covering materials of the chamber. In order to understand the effect of the external wind directions, the windward and downwind insulation properties were evaluated. As a result of comparing the thermal insulation effect of each greenhouse cover material to single-layer glass, the thermal insulation effect of double-layer glass was 16.9% higher, while PMMA and PC were 62.5% and 131.2% higher respectively. On average the wind speed on the windward side was 53.1% higher than that on the lee-wind side, and the temperature difference between the inside and outside of the chamber at the wind ward side was found to be 52.0% larger than that on the lee ward side. During the experiment period, the overall heating operation time for PC was 39.2% lower compared to other insulation materials. Showing highest energy efficiency, and compared to PC, single-layer glass power consumption was 37.4% higher.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.