Noise & Vibration Evaluation and Analysis for Propeller Fan System of Air Conditioner Outdoor Unit (에어컨 실외기 프로펠러 홴계의 진동소음 평가 및 해석)

  • Park, Deug-Yong;Mo, Jin-Yong;Lee, Jin-Kyo;Koo, Hyoung-Mo;Choi, Weon-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1405-1409
    • /
    • 2000
  • The electro-magnetic noise generated from fan-driving motor is one of important items in view of abnormal noise which affect the quality of air conditioner noise. The electro-magnetic noise of the outdoor unit is identified by the serial experiments for related parts, whose effects are verified to give proper measures for reduced noise level. The weight of fan appears to be the most important factor, and the stiffness of the frame, such as motor bracket is shown to be important also.

  • PDF

A Study on the Safety Consciousness of Resident for the Environmental Factors in Apartments (공동주택 환경요인에 대한 거주자의 안전의식 조사 연구)

  • Park, Hyeon-Ku;Song, Hyuk;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.106-113
    • /
    • 2005
  • The housing is a human's basic space and the comfort and the safety are the most basic conditions. According to the flow of age for Well-Being since the 21th, the suppliers and the users of apartment are making best effort now for the embossment of green environmental quality of apartment, and outstretch their hands for marketing strategic purposes in a side of indoor and outdoor environment with distinctive elements. But these supply and use are on progress competitively with the simple distinction, it is thought that indoor and outdoor environment are must be promoted according to the survey of residents' consciousness. So this study aims to provide basic materials with residents for the promotion of comfortable dwelling environment by solving the basic safety problem and also aims to survey and analyze the residents' safety consciousness in object of physical and non-physical environmental quality of indoor and outdoor of apartment by analyzing indoor air quality pollution, the feeling of being victimize caused by air pollution and safety consciousness according to physical environment elements.

Assessment of indoor air micro-flora in selected schools

  • Katiyar, Vinita
    • Advances in environmental research
    • /
    • v.2 no.1
    • /
    • pp.61-80
    • /
    • 2013
  • Quantification of viable forms of microbial community (bacteria and fungi) using culture-dependent methods was done in order to characterize the indoor air quality (IAQ). Role of those factors, which may influence the concentration of viable counts of bacteria and fungi, like ventilation, occupancy, outdoor concentration and environmental parameters (temperature and relative humidity) were also determined. Volumetric-infiltration sampling technique was employed to collect air samples both inside and outside the schools. As regard of measurements of airborne viable culturable microflora of schools during one academic year, the level of TVMCs in school buildings was ranged between 803-5368 cfu/$m^3$. Viable counts of bacteria (VBCs) were constituted 63.7% of the mean total viable microbial counts where as viable counts of fungi (VFCs) formed 36.3% of the total. Mean a total viable microbial count (TVMCs) in three schools was 2491 cfu/$m^3$. Outdoor level of TVMCs was varied from 736-5855 cfu/$m^3$. Maximum and minimum VBCs were 3678-286 cfu/m3 respectively. Culturable fungal counts were ranged from 268-2089 cfu/$m^3$ in three schools. Significant positive correlation (p < 0.01) was indicated that indoor concentration of viable community reliant upon outdoor concentration. Temperature seemed to have a large effect (p < 0.05, p < 0.01) on the concentration of viable culturable microbial community rather than relative humidity. Consistent with the analysis and findings, the concentration of viable cultural counts of bacteria and fungi found indoors, were of several orders of magnitude, depending upon the potential of local, spatial and temporal factors, IO ratio appeared as a crucial indicator to identify the source of microbial contaminants.

Residence s Exposure to Nitrogen Dioxide and Indoor Air Characteristics (거주지역 실내공기 특성 및 이산화질소 노출에 관한 연구)

  • 양원호;배현주;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.183-192
    • /
    • 2002
  • Indoor air quality is affected by source strength of pollutants, ventilation rate, decay rate, outdoor level and so on. Although technologies exist to measure these factors directly, direct measurements of all factors are impractical in most field studies. The purpose of this study was to develop an alternative methods to estimate these factors by multiple measurements. Daily indoor and outdoor NO$_2$concentrations for 21 days in 20 houses in summer and winter, Seoul. Using a mass balance model and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor(emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the ventilation and source strength were estimated. During sampling period, geometric mean of natural ventilation was estimated to be 1.10$\pm$1.53 ACH, assuming a residential NO$_2$decay rate of 0.8 hr$^{-1}$ in summer. In winter, natural ventilation was 0.75$\pm$1.31 ACH. And mean source strengths in summer and winter were 14.8ppb/hr and 22.4ppb/hr, respectively. Although the method showed similar finding previous studies, the study did not measure ACH or the source strength of the house directly. As validation of natural ventilations, infiltrations were measured with $CO_2$tracer gas in 18 houses. Relationship between ventilation and infiltration was statistically correlated (Pearson r=0.63, p=0.02).

The Effect of Outdoor Air and Indoor Human Activity on Mass Concentrations of Size-Selective Particulate in Classrooms (대기오염과 실내 거주자의 활동도가 교실 내부의 입자 크기별 먼지 농도에 미치는 영향)

  • Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • This study evaluated the effects of the human activity and outdoor air on concentrations of size-selective particulate matters (PM) by conducting a realtime measurement in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. PM concentrations featured repetitive pattern of increasing during break time (including lunch hours) and cleaning time while decreasing during class hours. This trend was more prominent with inhalable PM and PM10 than fine PMs (PM2.5, PM1.0). The indoor/outdoor (I/O) ratio of inhalable PM and PM10 exceeded 1 while that of fine PMs was close to or below 1. The PM2.5 (out)/PM10 (out) ratio stood at 0.59 (${\pm}0.16$) and the PM2.5 (in)/PM10 (in) ratio was 0.29 (${\pm}0.09$), suggesting that occupant activity had a greater effect upon coarse particles (PM10-PM2.5) than upon fine particles (PM2.5, PM1.0). The correlations between the indoor and the outdoor PM concentrations showed a stronger positive correlation for fine particles than that of coarse particles. The linear regression analysis of PM concentrations indoor and outdoor indicated a higher determinant coefficient ($r^2>0.9$), and consistency for fine particles than in case of coarse particles. In conclusion, the results of this study suggest that the indoor coarse particle concentration is more attributed to occupant activity and the indoor fine particle concentration is more influenced by outdoor air pollution.

Research Study on Indoor Air Quality (IAQ) inside of the Subway Cabin in Seoul Metropolitan City (지하철 전동차 객실 내부 공기질 조사 연구)

  • Lee, Kyoung Bin;Kim, Jin Sik;Bae, Sung Joon;Kim, Shin Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.175-187
    • /
    • 2014
  • The subways play an important part in serious traffic problems. Almost seven million citizens a day are using subways as a means of traffic communication in the Seoul metropolitan city in 2012. However, the subway system is a semi-closed environment, so many serious problems occurred in subway stations and injured passengers' health. Platform screen doors (PSD) are expected to prevent negligent accident such as injury or death from falling and improve the air quality of the subway station. Installation of PSD at stations in Seoul metropolitan subway had been completed in December 2009. Consequently, the underground transportation system became a closed environment, so the air quality has improved the platforms, but it has deteriorated in the tunnels. Especially, the subway cabin has many doors, and the doors are frequently opened and closed. For this reason, the effect of door opening on subway cabin, dust flow inside the subway cabin. In this process, the maintenance work may influence the health of people who work underground, as well as that of subway users (passengers). In this study, we measured air quality inside and outside of the subway cabin line 2 in Seoul, Korea. This study focused on the investigation of Indoor Air Quality (IAQ) and measurement target pollutants are PM10, CO, $CO_2$, $NO_2$, $O_3$. It was found that levels of PM10, $CO_2$, and $NO_2$ inside subway cabin line 2 exceeded the Korea IAQ standard. Concentrations of PM10, $CO_2$, and $NO_2$ inside of the cabin are higher than outside of the cabin (Indoor Outdoor ratio is higher than 1.). Concentrations of CO, $O_3$ inside of the cabin are lower than outside of the cabin (Indoor Outdoor ratio is lower than 1.). There is a high correlation between $CO_2$ and passengers inside of the cabin and PM10 is only the weakest correlation with passengers. Therefore, it is important to find out the emission source of $NO_2$. The results of this study will be useful as fundamental data to study indoor air quality of a subway cabin.

Field Measurements of Indoor Air Quality in Apartment Units at Medium-size Cities (중소도시 공동주택의 실내공기질(새집증후군) 실측에 관한 연구)

  • Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.81-86
    • /
    • 2010
  • The main sources of the new house syndrome(sometimes it called sick building syndrome) are a concentration of formaldehyde (HCHO) and a concentration of total volatile organic compounds(TVOC). I had field measurements of indoor air quality in the apartment unit at medium-size cities(Y city, C city). I measured indoor air temperature, HCHO concentration in 16 units, TVOC concentration in 6 units and air tightness in 7 units. And I measured outdoor air quality, HCHO concentration and TVOC concentration. Mean concentration of HCHO was $357{\mu}g/m^3$(2006 standard=$120{\mu}g/m^3$), mean concentration of TVOC was $3,092{\mu}g/m^3$ and mean effective air leakage area was 193 cm2. There was a close relation between the indoor air temperature and HCHO concentration, between the indoor air temperature and TVOC concentration. Air tightness also had relation.

Impact of Air-side Economizer Control Considering Air Quality Index on Variable Air Volume System Performance

  • Cho, Sang-Hyeon;Park, Joon-Young;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.1
    • /
    • pp.101-111
    • /
    • 2017
  • The objective of this study is to determine the effectiveness of a modified air-side economizer in improving indoor air quality (IAQ). An air-side economizer, which uses all outdoor air for cooling, affects the building's IAQ depending on the outside air quality and can significantly affect the occupants' health, leading to respiratory and heart disease. The Air Quality Index (AQI), developed by the US Environmental Protection Agency (US EPA), measures air contaminants that adversely affect human beings: PM10, PM2.5, SO2, NO2, O3, and CO. In this study, AQI is applied as a control for the operation of an air-side economizer. The simulation is analyzed, comparing the results between the differential enthalpy economizer and AQI-modified economizer. The results confirm that an AQI-modified economizer has a positive effect on IAQ. Compared to the operating differential enthalpy economizer, energy increase in an operating AQI-modified economizer is 0.65% in Shanghai and 0.8% in Seoul.

Applied Horticultural Biotechnology for the Mitigation of Indoor Air Pollution

  • Torpy, Fraser R.;Pettit, Thomas;Irga, Peter J.
    • Journal of People, Plants, and Environment
    • /
    • v.21 no.6
    • /
    • pp.445-460
    • /
    • 2018
  • Exposure to indoor air pollution is an emerging world-wide problem, with growing evidence that it is a major cause of morbidity worldwide. Whilst most indoor air pollutants are of outdoor origin, these combine with a range of indoor sourced pollutants that may lead to high pollutant levels indoors. The pollutants of greatest concern are volatile organic compounds (VOCs) and particulate matter (PM), both of which are associated with a range of serious health problems. Whilst current buildings usually use ventilation with outdoor air to remove these pollutants, botanical systems are gaining recognition as an effective alternative. Whilst many years research has shown that traditional potted plants and their substrates are capable of removing VOCs effectively, they are inefficient at removing PM, and are limited in their pollutant removal rates by the need for pollutants to diffuse to the active pollutant removal components of these systems. Active botanical biofiltration, using green wall systems combined with mechanical fans to increase pollutant exposure to the plants and substrate, show greatly increased rates of pollutant removal for both VOCs, PM and also carbon dioxide ($CO_2$). A developing body of research indicates that these systems can outperform existing technologies for indoor air pollutant removal, although further research is required before their use will become widespread. Whilst it is known that plant species selection and substrate characteristics can affect the performance of active botanical systems, optimal characteristics are yet to be identified. Once this research has been completed, it is proposed that active botanical biofiltration will provide a cheap and low energy use alternative to mechanical ventilations systems for the maintenance of indoor environmental quality.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at Kwangju Area

  • Son, Bu-Soon;Song, Mi-Ra;Yang, Won-Ho;Chung, Young-Dall;Pack, Jong-An
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.373-377
    • /
    • 2005
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals and from chemicals are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCS and particulate matter($PM_{10}$) during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and PM lo were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor sources and outdoor sources. Therefore, proper management methods should be taken to improve the indoor air quality in beauty shops.

  • PDF