• Title/Summary/Keyword: out-of-control

Search Result 15,008, Processing Time 0.04 seconds

Simultaneous out-of-plane and in-plane vibration mitigations of offshore monopile wind turbines by tuned mass dampers

  • Zuo, Haoran;Bi, Kaiming;Hao, Hong
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.435-449
    • /
    • 2020
  • To effectively extract the vast wind resource, offshore wind turbines are designed with large rotor and slender tower, which makes them vulnerable to external vibration sources such as wind and wave loads. Substantial research efforts have been devoted to mitigate the unwanted vibrations of offshore wind turbines to ensure their serviceability and safety in the normal working condition. However, most previous studies investigated the vibration control of wind turbines in one direction only, i.e., either the out-of-plane or in-plane direction. In reality, wind turbines inevitably vibrate in both directions when they are subjected to the external excitations. The studies on both the in-plane and out-of-plane vibration control of wind turbines are, however, scarce. In the present study, the NREL 5 MW wind turbine is taken as an example, a detailed three-dimensional (3D) Finite Element (FE) model of the wind turbine is developed in ABAQUS. To simultaneously control the in-plane and out-of-plane vibrations induced by the combined wind and wave loads, another carefully designed (i.e., tuned) spring and dashpot are added to the perpendicular direction of each Tuned Mass Damper (TMD) system that is used to control the vibrations of the tower and blades in one particular direction. With this simple modification, a bi-directional TMD system is formed and the vibrations in both the out-of-plane and in-plane directions are simultaneously suppressed. To examine the control effectiveness, the responses of the wind turbine without control, with separate TMD system and the proposed bi-directional TMD system are calculated and compared. Numerical results show that the bi-directional TMD system can simultaneously control the out-of-plane and in-plane vibrations of the wind turbine without changing too much of the conventional design of the control system. The bi-directional control system therefore could be a cost-effective solution to mitigate the bi-directional vibrations of offshore wind turbines.

The Effect of the ETC(Electronic Throttle Control) Characteristics on the Vehicle Driveability at Tip-in/out (스로틀 전자제어 방식에서 제어 특성이 차량의 가/감속 시 운전성에 미치는 영향)

  • Park, Kyoung-Seok;Lee, Jong-Hwa;Park, Jin-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.113-119
    • /
    • 2005
  • The passenger car drivers want in general to feel good driveability, but they sometimes feel uncomfortable by shock and jerk phenomenon when they push or release acceleration pedal with clutch engaged. In this paper, the shock and jerk characteristics are studied on the vehicles of the throttle-by-wire system. With this system, the throttle is not directly controlled by drivers but via a microprocessor. So the control logic of the throttle is very important on tip-in and tip-out driveability. Experiments were carried out on two vehicles which show different control characteristics. The torque control logics were analyzed by measuring cylinder pressures. The results show that special torque control logic is needed at tip-in/out state for good driveability.

Residual Vibration Control of High Speed Take-out Robot Used for Handling of Injection Mold Plastic Part (고속운동 플라스틱 금형사출 부품 취출 로봇의 잔류진동 제어)

  • Rhim, Sung-Soo;Park, Joo-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1025-1031
    • /
    • 2011
  • Take-out robots used for handling of the plastic parts manufactured with the injection mold are usually the gantry type that consists of long and thin links, The performance of the take-out robot is determined by the speed of the motion and the positioning accuracy to grab the part out of the mold, As the speed of the robot increases the flexure in the links of the take-out robot becomes more significant and it results in more residual vibration, The residual vibration deteriorates the positioning accuracy and compels the operator to slow down the motion of the robot. The typical method to reduce the vibration in the robot requires stiffening the links and/or slowing down the robot, Vibration control could achieve the desired performance without increasing the manufacturing cost or the operation cost that would be incurred otherwise, Considering the point-to-point nature of the task to be performed by the take-out robot the time-delay command (or input) shaping filter approach would be the most effective control method to be adopted among a few available control schemes. In this paper a direct adaptive command shaping filter (ACSF) algorithm has been modified and applied to design the optimal command shaping filters for various configuration of the take-out robot. Optimal filters designed by ACSF algorithm have been implemented on a take-out robot and the effectiveness of the designed filters in terms of vibration suppression has been verified for multiple positions of the robot.

Influence of VRE Knowledge and Awareness with VRE Infection Control in Compliance with VRE Infection Control among Nurses in Intensive Care Units (중환자실 간호사의 VRE에 대한 지식과 감염관리 인지도가 감염관리 수행에 미치는 영향)

  • Park, Young-Mi;Park, Kyung-Yeon
    • Journal of Korean Biological Nursing Science
    • /
    • v.11 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Purpose: The purpose of this study was to identify the influence of Vancomycin-resistant enterococcus (VRE) knowledge and awareness with VRE infection control in compliance with VRE infection control among nurses in intensive care units. Method: Participants (N=154) were recruited in B city from August 2007 to October 2007. Data were analyzed with SPSS PC+. Result: The degree of VRE knowledge of the participants was 12.41 out of the total score, 17; that of awareness with VRE infection control was 3.87 out of the total score, 4; that of compliance with VRE infection control 3.75 out of the perfect score, 4. A significantly positive relationship between awareness of VRE infection control and compliance with VRE infection control has been observed. Awareness with VRE infection control and type of intensive care unitpredicted 21.1% of the variance in compliance with VRE infection control. Conclusion: The study indicated that awareness with VRE infection control has the most important impact on the compliance with VRE infection control for the participants. Based on the finding, a suggestion is made to continue the research on VRE knowledge and nosocomical infection on the subject of nurse and nurse managers who are responsible for infection control in a medical institution.

  • PDF

A Study of the Driveability Improvement on the Electronic Throttle Control M/T Vehicle at Tip-in/out (스로틀 전자제어 방식 M/T차량의 가/감속 시 운전성 향상에 관한 연구)

  • Park, Kyoung-Seok;Lee, Jong-Hwa;Park, Jin-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • The passenger car drivers want in general to feel good driveability, but they sometimes feel uncomfortable by shock and jerk phenomena when they push or release acceleration pedal with clutch on state. In this paper, the shock and jerk characteristics are studied on the vehicles controlled by the throttle-by-wire system. Experiments and simulations were carried out on two vehicles which show different control characteristics. The engine torque control characteristics was analyzed by measuring cylinder pressure. Various specification factors of the vehicles and the torque control logic of the engines were simulated through experimental data basis. The result shows the spring effect of the trans-axle in the drive-train is one of the most important factors of the shock-jerk phenomena and the engine torque control method is also responsible for the reducing the shock-jerk amplitude. In this paper a new control logic of the engine torque is suggested for the better driveablility on the tip-in/out event.

Characterics of Meter-In / Meter-Out Circuits to pneumatic System (공압회로에서 미터인 회로와 미터아웃 회로의 특성 비교)

  • 박재범;염만오
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.446-450
    • /
    • 2002
  • Pneumatic system has been mainly used as main equipment for actuation and control of compressed air force in manufacturing industry, pneumatic circuit for the most part is used in Meter-Out circuit. Meter-Out circuit method is Flow Control Valve to fit in exhaust part of cylinder port. In the reverse, Meter-In circuit is Flow Control Valve to fit in input part of cylinder port. This study examines the dynamic characteristics comparison of Meter-In and Meter-Out Circuits in the pneumatic circuits. The results of the experimental research are obtained to the followings: i ) System Response is Meter-In Circuit more than Meter-Out one before cushion zone. ii) we conjectured that the collision of piston and head cover is ease to collide Meter-In Circuit more than Meter-Out one at the stroke end part.

  • PDF

Effect of Infection Control Knowledge and Nursing Work Environment on Infection Control Performance among General Hospital Nurses (종합병원 간호사의 감염관리지식, 간호근무환경이 감염관리수행도에 미치는 영향)

  • Choi, Kyunga;Moon, Mikyung
    • Journal of muscle and joint health
    • /
    • v.30 no.2
    • /
    • pp.120-128
    • /
    • 2023
  • Purpose: The purpose of the study was to investigate the effects of infection control knowledge and nursing work environment on infection control performance among general hospital nurses. Methods: A total of 138 nurses from four general hospitals located in G and P cities participated in this descriptive study. The collected data were analyzed using t-test, ANOVA, Pearson's correlation coefficients, and multiple regression. Results: The average mean score was 21.41±1.92 points out of 25 for infection control knowledge, 2.53±0.33 points out of 4 for nursing work environment, and 4.62±0.40 points out of 5 for infection control performance. In the final analysis, the variables that had the greatest influence on infection control performance were the nursing work environment (β=.32, p<.001), working department (β=.19, p=.014), and knowledge (β=.19, p=.016). Conclusion: This study showed that nurses with a better nursing work environment, employment in general department, and more infection control knowledge delivered superior infection control performance. Therefore, to improve infection control performance, it is necessary to enhance the nursing environment and develop practical education programs for augmenting infection control knowledge.

Quantitative Analysis and Comparisons between In-Phase Control and Energy-Optimized Control for Series Power Quality Controllers

  • Xinming, Hunag;Jinjun, Liu;Hui, Zhang
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.553-566
    • /
    • 2009
  • In-phase control and energy-optimized control are the two major control strategies proposed for series power quality controllers (SPQC). However quantitative analysis and comparison between these two control strategies is quite limited in previous publications. In this paper, an extensive quantitative analysis is carried out on these two control strategies through phasor diagram approach, and a detailed quantitative comparison is conducted accordingly. The load current is used as the reference phasor, and this leads to a simpler and clearer phasor diagram for the quantitative relationship. Subsequently detailed analysis of SPQC using in-phase control and energy-optimized control are provided respectively, under different modes both for under voltage/voltage sag and for over voltage/voltage swell. The closed form analytic expressions and the curves describing SPQC compensation characteristics are obtained. The detailed system power flow is figured out for each mode, and the detailed quantitative comparison between the two control strategies is then carried out. The comparison covers several aspects of SPQC, such as required compensating voltage magnitude, required capacity of energy storage component, and maximal ride-through time. In the end, computer simulation and prototype experimental results are shown to verify the validity of all the analysis and the result of the comparison.

Development of a Motion Simulator for Portable Type Welding Robot Based on Adaptive Control (적응 제어 기반 Portable 용접 로봇 시뮬레이터 개발)

  • Ku, Nam-Kug;Ha, Sol;Roh, Myung-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.5
    • /
    • pp.400-409
    • /
    • 2012
  • It is not easy to know the accurate mass and mass moment of inertia of robot. Because of this uncertainty, error may exist when we control the robot based on the inaccurate mass information. Moreover the properties of the portable robot can change during its operation. Therefore we developed the motion simulator based on the adaptive control. First, the computed torque control was carried out in order to minimize an error between target angles and real angles. The computed torque control is based on the equation of robot motion, which is derived from the Lagrange-Euler equation. To minimize the error between the real model and the approximated model, the adaptive control was carried out. During this simulation, the interference check was also carried out. The interference check verifies that the robot can move successfully without any collision.

A comparison of single charts for non-normal data (비정규성 데이터에 대한 단일 관리도들의 비교)

  • Kang, Myunggoo;Lee, Jangtaek
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.3
    • /
    • pp.729-738
    • /
    • 2015
  • In this paper, we compare the robustness to the assumption of normality of the single control charts to control the mean and variance simultaneously. The charts examined were semicircle control chart, max chart and MSE chart with Shewhart individuals control charts. Their in-control and out-of-control performance were studied by simulation combined with computation. We calculated false alarm rate to compare among single charts by changing subgroup size and shifting mean of quality characteristics. It turns out that max chart is more robust than any of the others if the process is in-control. In some cases max chart and MSE chart are more robust than others if the process is out-of-control.